|
|
|
/**
|
|
|
|
* Marlin 3D Printer Firmware
|
|
|
|
* Copyright (C) 2016 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
|
|
|
|
*
|
|
|
|
* Based on Sprinter and grbl.
|
|
|
|
* Copyright (C) 2011 Camiel Gubbels / Erik van der Zalm
|
|
|
|
*
|
|
|
|
* This program is free software: you can redistribute it and/or modify
|
|
|
|
* it under the terms of the GNU General Public License as published by
|
|
|
|
* the Free Software Foundation, either version 3 of the License, or
|
|
|
|
* (at your option) any later version.
|
|
|
|
*
|
|
|
|
* This program is distributed in the hope that it will be useful,
|
|
|
|
* but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
|
|
* GNU General Public License for more details.
|
|
|
|
*
|
|
|
|
* You should have received a copy of the GNU General Public License
|
|
|
|
* along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
|
|
*
|
|
|
|
*/
|
|
|
|
|
|
|
|
#include "MarlinConfig.h"
|
|
|
|
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_UBL) && ENABLED(UBL_G26_MESH_EDITING)
|
|
|
|
//#include "vector_3.h"
|
|
|
|
//#include "qr_solve.h"
|
|
|
|
|
|
|
|
#include "UBL.h"
|
|
|
|
#include "Marlin.h"
|
|
|
|
#include "hex_print_routines.h"
|
|
|
|
#include "configuration_store.h"
|
|
|
|
#include "planner.h"
|
|
|
|
#include "ultralcd.h"
|
|
|
|
|
|
|
|
#include <math.h>
|
|
|
|
|
|
|
|
void lcd_babystep_z();
|
|
|
|
void lcd_return_to_status();
|
|
|
|
bool lcd_clicked();
|
|
|
|
void lcd_implementation_clear();
|
|
|
|
void lcd_mesh_edit_setup(float initial);
|
|
|
|
float lcd_mesh_edit();
|
|
|
|
void lcd_z_offset_edit_setup(float);
|
|
|
|
float lcd_z_offset_edit();
|
|
|
|
extern float meshedit_done;
|
|
|
|
extern long babysteps_done;
|
|
|
|
extern float code_value_float();
|
|
|
|
extern bool code_value_bool();
|
|
|
|
extern bool code_has_value();
|
|
|
|
extern float probe_pt(float x, float y, bool, int);
|
|
|
|
extern float zprobe_zoffset;
|
|
|
|
extern bool set_probe_deployed(bool);
|
|
|
|
#define DEPLOY_PROBE() set_probe_deployed(true)
|
|
|
|
#define STOW_PROBE() set_probe_deployed(false)
|
|
|
|
bool ProbeStay = true;
|
|
|
|
|
|
|
|
constexpr float ubl_3_point_1_X = UBL_PROBE_PT_1_X,
|
|
|
|
ubl_3_point_1_Y = UBL_PROBE_PT_1_Y,
|
|
|
|
ubl_3_point_2_X = UBL_PROBE_PT_2_X,
|
|
|
|
ubl_3_point_2_Y = UBL_PROBE_PT_2_Y,
|
|
|
|
ubl_3_point_3_X = UBL_PROBE_PT_3_X,
|
|
|
|
ubl_3_point_3_Y = UBL_PROBE_PT_3_Y;
|
|
|
|
|
|
|
|
#define SIZE_OF_LITTLE_RAISE 0
|
|
|
|
#define BIG_RAISE_NOT_NEEDED 0
|
|
|
|
extern void lcd_quick_feedback();
|
|
|
|
|
|
|
|
/**
|
|
|
|
* G29: Unified Bed Leveling by Roxy
|
|
|
|
*
|
|
|
|
* Parameters understood by this leveling system:
|
|
|
|
*
|
|
|
|
* A Activate Activate the Unified Bed Leveling system.
|
|
|
|
*
|
|
|
|
* B # Business Use the 'Business Card' mode of the Manual Probe subsystem. This is invoked as
|
|
|
|
* G29 P2 B The mode of G29 P2 allows you to use a bussiness card or recipe card
|
|
|
|
* as a shim that the nozzle will pinch as it is lowered. The idea is that you
|
|
|
|
* can easily feel the nozzle getting to the same height by the amount of resistance
|
|
|
|
* the business card exhibits to movement. You should try to achieve the same amount
|
|
|
|
* of resistance on each probed point to facilitate accurate and repeatable measurements.
|
|
|
|
* You should be very careful not to drive the nozzle into the bussiness card with a
|
|
|
|
* lot of force as it is very possible to cause damage to your printer if your are
|
|
|
|
* careless. If you use the B option with G29 P2 B you can leave the number parameter off
|
|
|
|
* on its first use to enable measurement of the business card thickness. Subsequent usage
|
|
|
|
* of the B parameter can have the number previously measured supplied to the command.
|
|
|
|
* Incidently, you are much better off using something like a Spark Gap feeler gauge than
|
|
|
|
* something that compresses like a Business Card.
|
|
|
|
*
|
|
|
|
* C Continue Continue, Constant, Current Location. This is not a primary command. C is used to
|
|
|
|
* further refine the behaviour of several other commands. Issuing a G29 P1 C will
|
|
|
|
* continue the generation of a partially constructed Mesh without invalidating what has
|
|
|
|
* been done. Issuing a G29 P2 C will tell the Manual Probe subsystem to use the current
|
|
|
|
* location in its search for the closest unmeasured Mesh Point. When used with a G29 Z C
|
|
|
|
* it indicates to use the current location instead of defaulting to the center of the print bed.
|
|
|
|
*
|
|
|
|
* D Disable Disable the Unified Bed Leveling system.
|
|
|
|
*
|
|
|
|
* E Stow_probe Stow the probe after each sampled point.
|
|
|
|
*
|
|
|
|
* F # Fade * Fade the amount of Mesh Based Compensation over a specified height. At the
|
|
|
|
* specified height, no correction is applied and natural printer kenimatics take over. If no
|
|
|
|
* number is specified for the command, 10mm is assumed to be reasonable.
|
|
|
|
*
|
|
|
|
* G # Grid * Perform a Grid Based Leveling of the current Mesh using a grid with n points on a side.
|
|
|
|
*
|
|
|
|
* H # Height Specify the Height to raise the nozzle after each manual probe of the bed. The
|
|
|
|
* default is 5mm.
|
|
|
|
*
|
|
|
|
* I # Invalidate Invalidate specified number of Mesh Points. The nozzle location is used unless
|
|
|
|
* the X and Y parameter are used. If no number is specified, only the closest Mesh
|
|
|
|
* point to the location is invalidated. The M parameter is available as well to produce
|
|
|
|
* a map after the operation. This command is useful to invalidate a portion of the
|
|
|
|
* Mesh so it can be adjusted using other tools in the Unified Bed Leveling System. When
|
|
|
|
* attempting to invalidate an isolated bad point in the mesh, the M option will indicate
|
|
|
|
* where the nozzle is positioned in the Mesh with (#). You can move the nozzle around on
|
|
|
|
* the bed and use this feature to select the center of the area (or cell) you want to
|
|
|
|
* invalidate.
|
|
|
|
*
|
|
|
|
* K # Kompare Kompare current Mesh with stored Mesh # replacing current Mesh with the result. This
|
|
|
|
* command literally performs a diff between two Meshes.
|
|
|
|
*
|
|
|
|
* L Load * Load Mesh from the previously activated location in the EEPROM.
|
|
|
|
*
|
|
|
|
* L # Load * Load Mesh from the specified location in the EEPROM. Set this location as activated
|
|
|
|
* for subsequent Load and Store operations.
|
|
|
|
*
|
|
|
|
* O Map * Display the Mesh Map Topology.
|
|
|
|
* The parameter can be specified alone (ie. G29 O) or in combination with many of the
|
|
|
|
* other commands. The Mesh Map option works with all of the Phase
|
|
|
|
* commands (ie. G29 P4 R 5 X 50 Y100 C -.1 O) The Map parameter can also of a Map Type
|
|
|
|
* specified. A map type of 0 is the default is user readable. A map type of 1 can
|
|
|
|
* be specified and is suitable to Cut & Paste into Excel to allow graphing of the user's
|
|
|
|
* mesh.
|
|
|
|
*
|
|
|
|
* N No Home G29 normally insists that a G28 has been performed. You can over rule this with an
|
|
|
|
* N option. In general, you should not do this. This can only be done safely with
|
|
|
|
* commands that do not move the nozzle.
|
|
|
|
*
|
|
|
|
* The P or Phase commands are used for the bulk of the work to setup a Mesh. In general, your Mesh will
|
|
|
|
* start off being initialized with a G29 P0 or a G29 P1. Further refinement of the Mesh happens with
|
|
|
|
* each additional Phase that processes it.
|
|
|
|
*
|
|
|
|
* P0 Phase 0 Zero Mesh Data and turn off the Mesh Compensation System. This reverts the
|
|
|
|
* 3D Printer to the same state it was in before the Unified Bed Leveling Compensation
|
|
|
|
* was turned on. Setting the entire Mesh to Zero is a special case that allows
|
|
|
|
* a subsequent G or T leveling operation for backward compatibility.
|
|
|
|
*
|
|
|
|
* P1 Phase 1 Invalidate entire Mesh and continue with automatic generation of the Mesh data using
|
|
|
|
* the Z-Probe. Depending upon the values of DELTA_PROBEABLE_RADIUS and
|
|
|
|
* DELTA_PRINTABLE_RADIUS some area of the bed will not have Mesh Data automatically
|
|
|
|
* generated. This will be handled in Phase 2. If the Phase 1 command is given the
|
|
|
|
* C (Continue) parameter it does not invalidate the Mesh prior to automatically
|
|
|
|
* probing needed locations. This allows you to invalidate portions of the Mesh but still
|
|
|
|
* use the automatic probing capabilities of the Unified Bed Leveling System. An X and Y
|
|
|
|
* parameter can be given to prioritize where the command should be trying to measure points.
|
|
|
|
* If the X and Y parameters are not specified the current probe position is used. Phase 1
|
|
|
|
* allows you to specify the M (Map) parameter so you can watch the generation of the Mesh.
|
|
|
|
* Phase 1 also watches for the LCD Panel's Encoder Switch being held in a depressed state.
|
|
|
|
* It will suspend generation of the Mesh if it sees the user request that. (This check is
|
|
|
|
* only done between probe points. You will need to press and hold the switch until the
|
|
|
|
* Phase 1 command can detect it.)
|
|
|
|
*
|
|
|
|
* P2 Phase 2 Probe areas of the Mesh that can't be automatically handled. Phase 2 respects an H
|
|
|
|
* parameter to control the height between Mesh points. The default height for movement
|
|
|
|
* between Mesh points is 5mm. A smaller number can be used to make this part of the
|
|
|
|
* calibration less time consuming. You will be running the nozzle down until it just barely
|
|
|
|
* touches the glass. You should have the nozzle clean with no plastic obstructing your view.
|
|
|
|
* Use caution and move slowly. It is possible to damage your printer if you are careless.
|
|
|
|
* Note that this command will use the configuration #define SIZE_OF_LITTLE_RAISE if the
|
|
|
|
* nozzle is moving a distance of less than BIG_RAISE_NOT_NEEDED.
|
|
|
|
*
|
|
|
|
* The H parameter can be set negative if your Mesh dips in a large area. You can press
|
|
|
|
* and hold the LCD Panel's encoder wheel to terminate the current Phase 2 command. You
|
|
|
|
* can then re-issue the G29 P 2 command with an H parameter that is more suitable for the
|
|
|
|
* area you are manually probing. Note that the command tries to start you in a corner
|
|
|
|
* of the bed where movement will be predictable. You can force the location to be used in
|
|
|
|
* the distance calculations by using the X and Y parameters. You may find it is helpful to
|
|
|
|
* print out a Mesh Map (G29 O ) to understand where the mesh is invalidated and where
|
|
|
|
* the nozzle will need to move in order to complete the command. The C parameter is
|
|
|
|
* available on the Phase 2 command also and indicates the search for points to measure should
|
|
|
|
* be done based on the current location of the nozzle.
|
|
|
|
*
|
|
|
|
* A B parameter is also available for this command and described up above. It places the
|
|
|
|
* manual probe subsystem into Business Card mode where the thickness of a business care is
|
|
|
|
* measured and then used to accurately set the nozzle height in all manual probing for the
|
|
|
|
* duration of the command. (S for Shim mode would be a better parameter name, but S is needed
|
|
|
|
* for Save or Store of the Mesh to EEPROM) A Business card can be used, but you will have
|
|
|
|
* better results if you use a flexible Shim that does not compress very much. That makes it
|
|
|
|
* easier for you to get the nozzle to press with similar amounts of force against the shim so you
|
|
|
|
* can get accurate measurements. As you are starting to touch the nozzle against the shim try
|
|
|
|
* to get it to grasp the shim with the same force as when you measured the thickness of the
|
|
|
|
* shim at the start of the command.
|
|
|
|
*
|
|
|
|
* Phase 2 allows the O (Map) parameter to be specified. This helps the user see the progression
|
|
|
|
* of the Mesh being built.
|
|
|
|
*
|
|
|
|
* P3 Phase 3 Fill the unpopulated regions of the Mesh with a fixed value. The C parameter is
|
|
|
|
* used to specify the 'constant' value to fill all invalid areas of the Mesh. If no C parameter
|
|
|
|
* is specified, a value of 0.0 is assumed. The R parameter can be given to specify the number
|
|
|
|
* of points to set. If the R parameter is specified the current nozzle position is used to
|
|
|
|
* find the closest points to alter unless the X and Y parameter are used to specify the fill
|
|
|
|
* location.
|
|
|
|
*
|
|
|
|
* P4 Phase 4 Fine tune the Mesh. The Delta Mesh Compensation System assume the existance of
|
|
|
|
* an LCD Panel. It is possible to fine tune the mesh without the use of an LCD Panel.
|
|
|
|
* (More work and details on doing this later!)
|
|
|
|
* The System will search for the closest Mesh Point to the nozzle. It will move the
|
|
|
|
* nozzle to this location. The user can use the LCD Panel to carefully adjust the nozzle
|
|
|
|
* so it is just barely touching the bed. When the user clicks the control, the System
|
|
|
|
* will lock in that height for that point in the Mesh Compensation System.
|
|
|
|
*
|
|
|
|
* Phase 4 has several additional parameters that the user may find helpful. Phase 4
|
|
|
|
* can be started at a specific location by specifying an X and Y parameter. Phase 4
|
|
|
|
* can be requested to continue the adjustment of Mesh Points by using the R(epeat)
|
|
|
|
* parameter. If the Repetition count is not specified, it is assumed the user wishes
|
|
|
|
* to adjust the entire matrix. The nozzle is moved to the Mesh Point being edited.
|
|
|
|
* The command can be terminated early (or after the area of interest has been edited) by
|
|
|
|
* pressing and holding the encoder wheel until the system recognizes the exit request.
|
|
|
|
* Phase 4's general form is G29 P4 [R # of points] [X position] [Y position]
|
|
|
|
*
|
|
|
|
* Phase 4 is intended to be used with the G26 Mesh Validation Command. Using the
|
|
|
|
* information left on the printer's bed from the G26 command it is very straight forward
|
|
|
|
* and easy to fine tune the Mesh. One concept that is important to remember and that
|
|
|
|
* will make using the Phase 4 command easy to use is this: You are editing the Mesh Points.
|
|
|
|
* If you have too little clearance and not much plastic was extruded in an area, you want to
|
|
|
|
* LOWER the Mesh Point at the location. If you did not get good adheasion, you want to
|
|
|
|
* RAISE the Mesh Point at that location.
|
|
|
|
*
|
|
|
|
*
|
|
|
|
* P5 Phase 5 Find Mean Mesh Height and Standard Deviation. Typically, it is easier to use and
|
|
|
|
* work with the Mesh if it is Mean Adjusted. You can specify a C parameter to
|
|
|
|
* Correct the Mesh to a 0.00 Mean Height. Adding a C parameter will automatically
|
|
|
|
* execute a G29 P6 C <mean height>.
|
|
|
|
*
|
|
|
|
* P6 Phase 6 Shift Mesh height. The entire Mesh's height is adjusted by the height specified
|
|
|
|
* with the C parameter. Being able to adjust the height of a Mesh is useful tool. It
|
|
|
|
* can be used to compensate for poorly calibrated Z-Probes and other errors. Ideally,
|
|
|
|
* you should have the Mesh adjusted for a Mean Height of 0.00 and the Z-Probe measuring
|
|
|
|
* 0.000 at the Z Home location.
|
|
|
|
*
|
|
|
|
* Q Test * Load specified Test Pattern to assist in checking correct operation of system. This
|
|
|
|
* command is not anticipated to be of much value to the typical user. It is intended
|
|
|
|
* for developers to help them verify correct operation of the Unified Bed Leveling System.
|
|
|
|
*
|
|
|
|
* S Store Store the current Mesh in the Activated area of the EEPROM. It will also store the
|
|
|
|
* current state of the Unified Bed Leveling system in the EEPROM.
|
|
|
|
*
|
|
|
|
* S # Store Store the current Mesh at the specified location in EEPROM. Activate this location
|
|
|
|
* for subsequent Load and Store operations. It will also store the current state of
|
|
|
|
* the Unified Bed Leveling system in the EEPROM.
|
|
|
|
*
|
|
|
|
* S -1 Store Store the current Mesh as a print out that is suitable to be feed back into
|
|
|
|
* the system at a later date. The text generated can be saved and later sent by PronterFace or
|
|
|
|
* Repetier Host to reconstruct the current mesh on another machine.
|
|
|
|
*
|
|
|
|
* T 3-Point Perform a 3 Point Bed Leveling on the current Mesh
|
|
|
|
*
|
|
|
|
* U Unlevel Perform a probe of the outer perimeter to assist in physically leveling unlevel beds.
|
|
|
|
* Only used for G29 P1 O U It will speed up the probing of the edge of the bed. This
|
|
|
|
* is useful when the entire bed does not need to be probed because it will be adjusted.
|
|
|
|
*
|
|
|
|
* W What? Display valuable data the Unified Bed Leveling System knows.
|
|
|
|
*
|
|
|
|
* X # * * X Location for this line of commands
|
|
|
|
*
|
|
|
|
* Y # * * Y Location for this line of commands
|
|
|
|
*
|
|
|
|
* Z Zero * Probes to set the Z Height of the nozzle. The entire Mesh can be raised or lowered
|
|
|
|
* by just doing a G29 Z
|
|
|
|
*
|
|
|
|
* Z # Zero * The entire Mesh can be raised or lowered to conform with the specified difference.
|
|
|
|
* zprobe_zoffset is added to the calculation.
|
|
|
|
*
|
|
|
|
*
|
|
|
|
* Release Notes:
|
|
|
|
* You MUST do M502, M500 to initialize the storage. Failure to do this will cause all
|
|
|
|
* kinds of problems. Enabling EEPROM Storage is highly recommended. With EEPROM Storage
|
|
|
|
* of the mesh, you are limited to 3-Point and Grid Leveling. (G29 P0 T and G29 P0 G
|
|
|
|
* respectively.)
|
|
|
|
*
|
|
|
|
* When you do a G28 and then a G29 P1 to automatically build your first mesh, you are going to notice
|
|
|
|
* the Unified Bed Leveling probes points further and further away from the starting location. (The
|
|
|
|
* starting location defaults to the center of the bed.) The original Grid and Mesh leveling used
|
|
|
|
* a Zig Zag pattern. The new pattern is better, especially for people with Delta printers. This
|
|
|
|
* allows you to get the center area of the Mesh populated (and edited) quicker. This allows you to
|
|
|
|
* perform a small print and check out your settings quicker. You do not need to populate the
|
|
|
|
* entire mesh to use it. (You don't want to spend a lot of time generating a mesh only to realize
|
|
|
|
* you don't have the resolution or zprobe_zoffset set correctly. The Mesh generation
|
|
|
|
* gathers points closest to where the nozzle is located unless you specify an (X,Y) coordinate pair.
|
|
|
|
*
|
|
|
|
* The Unified Bed Leveling uses a lot of EEPROM storage to hold its data. And it takes some effort
|
|
|
|
* to get this Mesh data correct for a user's printer. We do not want this data destroyed as
|
|
|
|
* new versions of Marlin add or subtract to the items stored in EEPROM. So, for the benefit of
|
|
|
|
* the users, we store the Mesh data at the end of the EEPROM and do not keep it contiguous with the
|
|
|
|
* other data stored in the EEPROM. (For sure the developers are going to complain about this, but
|
|
|
|
* this is going to be helpful to the users!)
|
|
|
|
*
|
|
|
|
* The foundation of this Bed Leveling System is built on Epatel's Mesh Bed Leveling code. A big
|
|
|
|
* 'Thanks!' to him and the creators of 3-Point and Grid Based leveling. Combining their contributions
|
|
|
|
* we now have the functionality and features of all three systems combined.
|
|
|
|
*/
|
|
|
|
|
|
|
|
// The simple parameter flags and values are 'static' so parameter parsing can be in a support routine.
|
|
|
|
static int g29_verbose_level, phase_value = -1, repetition_cnt,
|
|
|
|
storage_slot = 0, map_type; //unlevel_value = -1;
|
|
|
|
static bool repeat_flag, c_flag, x_flag, y_flag;
|
|
|
|
static float x_pos, y_pos, measured_z, card_thickness = 0.0, ubl_constant = 0.0;
|
|
|
|
|
|
|
|
#if ENABLED(ULTRA_LCD)
|
|
|
|
void lcd_setstatus(const char* message, bool persist);
|
|
|
|
#endif
|
|
|
|
|
|
|
|
void gcode_G29() {
|
|
|
|
SERIAL_PROTOCOLLNPAIR("ubl.eeprom_start=", ubl.eeprom_start);
|
|
|
|
if (ubl.eeprom_start < 0) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("?You need to enable your EEPROM and initialize it");
|
|
|
|
SERIAL_PROTOCOLLNPGM("with M502, M500, M501 in that order.\n");
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (!code_seen('N') && axis_unhomed_error(true, true, true)) // Don't allow auto-leveling without homing first
|
|
|
|
gcode_G28();
|
|
|
|
|
|
|
|
if (g29_parameter_parsing()) return; // abort if parsing the simple parameters causes a problem,
|
|
|
|
|
|
|
|
// Invalidate Mesh Points. This command is a little bit asymetrical because
|
|
|
|
// it directly specifies the repetition count and does not use the 'R' parameter.
|
|
|
|
if (code_seen('I')) {
|
|
|
|
repetition_cnt = code_has_value() ? code_value_int() : 1;
|
|
|
|
while (repetition_cnt--) {
|
|
|
|
const mesh_index_pair location = find_closest_mesh_point_of_type(REAL, x_pos, y_pos, 0, NULL, false); // The '0' says we want to use the nozzle's position
|
|
|
|
if (location.x_index < 0) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("Entire Mesh invalidated.\n");
|
|
|
|
break; // No more invalid Mesh Points to populate
|
|
|
|
}
|
|
|
|
ubl.z_values[location.x_index][location.y_index] = NAN;
|
|
|
|
}
|
|
|
|
SERIAL_PROTOCOLLNPGM("Locations invalidated.\n");
|
|
|
|
}
|
|
|
|
|
|
|
|
if (code_seen('Q')) {
|
|
|
|
|
|
|
|
const int test_pattern = code_has_value() ? code_value_int() : -1;
|
|
|
|
if (test_pattern < 0 || test_pattern > 2) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("Invalid test_pattern value. (0-2)\n");
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
SERIAL_PROTOCOLLNPGM("Loading test_pattern values.\n");
|
|
|
|
switch (test_pattern) {
|
|
|
|
case 0:
|
|
|
|
for (uint8_t x = 0; x < UBL_MESH_NUM_X_POINTS; x++) { // Create a bowl shape - similar to
|
|
|
|
for (uint8_t y = 0; y < UBL_MESH_NUM_Y_POINTS; y++) { // a poorly calibrated Delta.
|
|
|
|
const float p1 = 0.5 * (UBL_MESH_NUM_X_POINTS) - x,
|
|
|
|
p2 = 0.5 * (UBL_MESH_NUM_Y_POINTS) - y;
|
|
|
|
ubl.z_values[x][y] += 2.0 * HYPOT(p1, p2);
|
|
|
|
}
|
|
|
|
}
|
|
|
|
break;
|
|
|
|
case 1:
|
|
|
|
for (uint8_t x = 0; x < UBL_MESH_NUM_X_POINTS; x++) { // Create a diagonal line several Mesh cells thick that is raised
|
|
|
|
ubl.z_values[x][x] += 9.999;
|
|
|
|
ubl.z_values[x][x + (x < UBL_MESH_NUM_Y_POINTS - 1) ? 1 : -1] += 9.999; // We want the altered line several mesh points thick
|
|
|
|
}
|
|
|
|
break;
|
|
|
|
case 2:
|
|
|
|
// Allow the user to specify the height because 10mm is a little extreme in some cases.
|
|
|
|
for (uint8_t x = (UBL_MESH_NUM_X_POINTS) / 3; x < 2 * (UBL_MESH_NUM_X_POINTS) / 3; x++) // Create a rectangular raised area in
|
|
|
|
for (uint8_t y = (UBL_MESH_NUM_Y_POINTS) / 3; y < 2 * (UBL_MESH_NUM_Y_POINTS) / 3; y++) // the center of the bed
|
|
|
|
ubl.z_values[x][y] += code_seen('C') ? ubl_constant : 9.99;
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
if (code_seen('U')) {
|
|
|
|
unlevel_value = code_value_int();
|
|
|
|
//if (unlevel_value < 0 || unlevel_value > 7) {
|
|
|
|
// SERIAL_PROTOCOLLNPGM("Invalid Unlevel value. (0-4)\n");
|
|
|
|
// return;
|
|
|
|
//}
|
|
|
|
}
|
|
|
|
//*/
|
|
|
|
|
|
|
|
if (code_seen('P')) {
|
|
|
|
phase_value = code_value_int();
|
|
|
|
if (phase_value < 0 || phase_value > 7) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("Invalid Phase value. (0-4)\n");
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
switch (phase_value) {
|
|
|
|
case 0:
|
|
|
|
//
|
|
|
|
// Zero Mesh Data
|
|
|
|
//
|
|
|
|
ubl.reset();
|
|
|
|
SERIAL_PROTOCOLLNPGM("Mesh zeroed.\n");
|
|
|
|
break;
|
|
|
|
|
|
|
|
case 1:
|
|
|
|
//
|
|
|
|
// Invalidate Entire Mesh and Automatically Probe Mesh in areas that can be reached by the probe
|
|
|
|
//
|
|
|
|
if (!code_seen('C') ) {
|
|
|
|
ubl.invalidate();
|
|
|
|
SERIAL_PROTOCOLLNPGM("Mesh invalidated. Probing mesh.\n");
|
|
|
|
}
|
|
|
|
if (g29_verbose_level > 1) {
|
|
|
|
SERIAL_ECHOPGM("Probing Mesh Points Closest to (");
|
|
|
|
SERIAL_ECHO(x_pos);
|
|
|
|
SERIAL_ECHOPAIR(",", y_pos);
|
|
|
|
SERIAL_PROTOCOLLNPGM(")\n");
|
|
|
|
}
|
|
|
|
probe_entire_mesh(x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER,
|
|
|
|
code_seen('O') || code_seen('M'), code_seen('E'), code_seen('U'));
|
|
|
|
break;
|
|
|
|
|
|
|
|
case 2: {
|
|
|
|
//
|
|
|
|
// Manually Probe Mesh in areas that can't be reached by the probe
|
|
|
|
//
|
|
|
|
SERIAL_PROTOCOLLNPGM("Manually probing unreachable mesh locations.\n");
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES);
|
|
|
|
if (!x_flag && !y_flag) { // use a good default location for the path
|
|
|
|
x_pos = X_MIN_POS;
|
|
|
|
y_pos = Y_MIN_POS;
|
|
|
|
if (X_PROBE_OFFSET_FROM_EXTRUDER > 0) // The flipped > and < operators on these two comparisons is
|
|
|
|
x_pos = X_MAX_POS; // intentional. It should cause the probed points to follow a
|
|
|
|
|
|
|
|
if (Y_PROBE_OFFSET_FROM_EXTRUDER < 0) // nice path on Cartesian printers. It may make sense to
|
|
|
|
y_pos = Y_MAX_POS; // have Delta printers default to the center of the bed.
|
|
|
|
|
|
|
|
} // For now, until that is decided, it can be forced with the X
|
|
|
|
// and Y parameters.
|
|
|
|
if (code_seen('C')) {
|
|
|
|
x_pos = current_position[X_AXIS];
|
|
|
|
y_pos = current_position[Y_AXIS];
|
|
|
|
}
|
|
|
|
|
|
|
|
const float height = code_seen('H') && code_has_value() ? code_value_float() : Z_CLEARANCE_BETWEEN_PROBES;
|
|
|
|
|
|
|
|
if (code_seen('B')) {
|
|
|
|
card_thickness = code_has_value() ? code_value_float() : measure_business_card_thickness(height);
|
|
|
|
|
|
|
|
if (fabs(card_thickness) > 1.5) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("?Error in Business Card measurement.\n");
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
manually_probe_remaining_mesh(x_pos, y_pos, height, card_thickness, code_seen('O') || code_seen('M'));
|
|
|
|
|
|
|
|
} break;
|
|
|
|
|
|
|
|
case 3: {
|
|
|
|
//
|
|
|
|
// Populate invalid Mesh areas with a constant
|
|
|
|
//
|
|
|
|
const float height = code_seen('C') ? ubl_constant : 0.0;
|
|
|
|
// If no repetition is specified, do the whole Mesh
|
|
|
|
if (!repeat_flag) repetition_cnt = 9999;
|
|
|
|
while (repetition_cnt--) {
|
|
|
|
const mesh_index_pair location = find_closest_mesh_point_of_type(INVALID, x_pos, y_pos, 0, NULL, false); // The '0' says we want to use the nozzle's position
|
|
|
|
if (location.x_index < 0) break; // No more invalid Mesh Points to populate
|
|
|
|
ubl.z_values[location.x_index][location.y_index] = height;
|
|
|
|
}
|
|
|
|
} break;
|
|
|
|
|
|
|
|
case 4:
|
|
|
|
//
|
|
|
|
// Fine Tune (i.e., Edit) the Mesh
|
|
|
|
//
|
|
|
|
fine_tune_mesh(x_pos, y_pos, code_seen('O') || code_seen('M'));
|
|
|
|
break;
|
|
|
|
case 5:
|
|
|
|
find_mean_mesh_height();
|
|
|
|
break;
|
|
|
|
case 6:
|
|
|
|
shift_mesh_height();
|
|
|
|
break;
|
|
|
|
|
|
|
|
case 10:
|
|
|
|
// [DEBUG] Pay no attention to this stuff. It can be removed soon.
|
|
|
|
SERIAL_ECHO_START;
|
|
|
|
SERIAL_ECHOLNPGM("Checking G29 has control of LCD Panel:");
|
|
|
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
|
|
|
ubl.has_control_of_lcd_panel++;
|
|
|
|
while (!ubl_lcd_clicked()) {
|
|
|
|
safe_delay(250);
|
|
|
|
if (ubl.encoder_diff) {
|
|
|
|
SERIAL_ECHOLN((int)ubl.encoder_diff);
|
|
|
|
ubl.encoder_diff = 0;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
SERIAL_ECHOLNPGM("G29 giving back control of LCD Panel.");
|
|
|
|
ubl.has_control_of_lcd_panel = false;
|
|
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
|
|
break;
|
|
|
|
|
|
|
|
case 11:
|
|
|
|
// [DEBUG] wait_for_user code. Pay no attention to this stuff. It can be removed soon.
|
|
|
|
SERIAL_ECHO_START;
|
|
|
|
SERIAL_ECHOLNPGM("Checking G29 has control of LCD Panel:");
|
|
|
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
|
|
|
wait_for_user = true;
|
|
|
|
while (wait_for_user) {
|
|
|
|
safe_delay(250);
|
|
|
|
if (ubl.encoder_diff) {
|
|
|
|
SERIAL_ECHOLN((int)ubl.encoder_diff);
|
|
|
|
ubl.encoder_diff = 0;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
SERIAL_ECHOLNPGM("G29 giving back control of LCD Panel.");
|
|
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
|
|
break;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
if (code_seen('T')) {
|
|
|
|
float z1 = probe_pt(ubl_3_point_1_X, ubl_3_point_1_Y, false /*Stow Flag*/, g29_verbose_level) + zprobe_zoffset,
|
|
|
|
z2 = probe_pt(ubl_3_point_2_X, ubl_3_point_2_Y, false /*Stow Flag*/, g29_verbose_level) + zprobe_zoffset,
|
|
|
|
z3 = probe_pt(ubl_3_point_3_X, ubl_3_point_3_Y, true /*Stow Flag*/, g29_verbose_level) + zprobe_zoffset;
|
|
|
|
|
|
|
|
// We need to adjust z1, z2, z3 by the Mesh Height at these points. Just because they are non-zero doesn't mean
|
|
|
|
// the Mesh is tilted! (We need to compensate each probe point by what the Mesh says that location's height is)
|
|
|
|
|
|
|
|
z1 -= ubl.get_z_correction(ubl_3_point_1_X, ubl_3_point_1_Y);
|
|
|
|
z2 -= ubl.get_z_correction(ubl_3_point_2_X, ubl_3_point_2_Y);
|
|
|
|
z3 -= ubl.get_z_correction(ubl_3_point_3_X, ubl_3_point_3_Y);
|
|
|
|
|
|
|
|
do_blocking_move_to_xy((X_MAX_POS - (X_MIN_POS)) / 2.0, (Y_MAX_POS - (Y_MIN_POS)) / 2.0);
|
|
|
|
tilt_mesh_based_on_3pts(z1, z2, z3);
|
|
|
|
}
|
|
|
|
|
|
|
|
//
|
|
|
|
// Much of the 'What?' command can be eliminated. But until we are fully debugged, it is
|
|
|
|
// good to have the extra information. Soon... we prune this to just a few items
|
|
|
|
//
|
|
|
|
if (code_seen('W')) g29_what_command();
|
|
|
|
|
|
|
|
//
|
|
|
|
// When we are fully debugged, the EEPROM dump command will get deleted also. But
|
|
|
|
// right now, it is good to have the extra information. Soon... we prune this.
|
|
|
|
//
|
|
|
|
if (code_seen('J')) g29_eeprom_dump(); // EEPROM Dump
|
|
|
|
|
|
|
|
//
|
|
|
|
// When we are fully debugged, this may go away. But there are some valid
|
|
|
|
// use cases for the users. So we can wait and see what to do with it.
|
|
|
|
//
|
|
|
|
|
|
|
|
if (code_seen('K')) // Kompare Current Mesh Data to Specified Stored Mesh
|
|
|
|
g29_compare_current_mesh_to_stored_mesh();
|
|
|
|
|
|
|
|
//
|
|
|
|
// Load a Mesh from the EEPROM
|
|
|
|
//
|
|
|
|
|
|
|
|
if (code_seen('L')) { // Load Current Mesh Data
|
|
|
|
storage_slot = code_has_value() ? code_value_int() : ubl.state.eeprom_storage_slot;
|
|
|
|
|
|
|
|
const int16_t j = (UBL_LAST_EEPROM_INDEX - ubl.eeprom_start) / sizeof(ubl.z_values);
|
|
|
|
|
|
|
|
if (storage_slot < 0 || storage_slot >= j || ubl.eeprom_start <= 0) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available for use.\n");
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
ubl.load_mesh(storage_slot);
|
|
|
|
ubl.state.eeprom_storage_slot = storage_slot;
|
|
|
|
if (storage_slot != ubl.state.eeprom_storage_slot)
|
|
|
|
ubl.store_state();
|
|
|
|
SERIAL_PROTOCOLLNPGM("Done.\n");
|
|
|
|
}
|
|
|
|
|
|
|
|
//
|
|
|
|
// Store a Mesh in the EEPROM
|
|
|
|
//
|
|
|
|
|
|
|
|
if (code_seen('S')) { // Store (or Save) Current Mesh Data
|
|
|
|
storage_slot = code_has_value() ? code_value_int() : ubl.state.eeprom_storage_slot;
|
|
|
|
|
|
|
|
if (storage_slot == -1) { // Special case, we are going to 'Export' the mesh to the
|
|
|
|
SERIAL_ECHOLNPGM("G29 I 999"); // host in a form it can be reconstructed on a different machine
|
|
|
|
for (uint8_t x = 0; x < UBL_MESH_NUM_X_POINTS; x++)
|
|
|
|
for (uint8_t y = 0; y < UBL_MESH_NUM_Y_POINTS; y++)
|
|
|
|
if (!isnan(ubl.z_values[x][y])) {
|
|
|
|
SERIAL_ECHOPAIR("M421 I ", x);
|
|
|
|
SERIAL_ECHOPAIR(" J ", y);
|
|
|
|
SERIAL_ECHOPGM(" Z ");
|
|
|
|
SERIAL_ECHO_F(ubl.z_values[x][y], 6);
|
|
|
|
SERIAL_EOL;
|
|
|
|
}
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
const int16_t j = (UBL_LAST_EEPROM_INDEX - ubl.eeprom_start) / sizeof(ubl.z_values);
|
|
|
|
|
|
|
|
if (storage_slot < 0 || storage_slot >= j || ubl.eeprom_start <= 0) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available for use.\n");
|
|
|
|
SERIAL_PROTOCOLLNPAIR("?Use 0 to ", j - 1);
|
|
|
|
goto LEAVE;
|
|
|
|
}
|
|
|
|
ubl.store_mesh(storage_slot);
|
|
|
|
ubl.state.eeprom_storage_slot = storage_slot;
|
|
|
|
//
|
|
|
|
// if (storage_slot != ubl.state.eeprom_storage_slot)
|
|
|
|
ubl.store_state(); // Always save an updated copy of the UBL State info
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLLNPGM("Done.\n");
|
|
|
|
}
|
|
|
|
|
|
|
|
if (code_seen('O') || code_seen('M'))
|
|
|
|
ubl.display_map(code_has_value() ? code_value_int() : 0);
|
|
|
|
|
|
|
|
if (code_seen('Z')) {
|
|
|
|
if (code_has_value())
|
|
|
|
ubl.state.z_offset = code_value_float(); // do the simple case. Just lock in the specified value
|
|
|
|
else {
|
|
|
|
save_ubl_active_state_and_disable();
|
|
|
|
//measured_z = probe_pt(x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER, ProbeDeployAndStow, g29_verbose_level);
|
|
|
|
|
|
|
|
ubl.has_control_of_lcd_panel++; // Grab the LCD Hardware
|
|
|
|
measured_z = 1.5;
|
|
|
|
do_blocking_move_to_z(measured_z); // Get close to the bed, but leave some space so we don't damage anything
|
|
|
|
// The user is not going to be locking in a new Z-Offset very often so
|
|
|
|
// it won't be that painful to spin the Encoder Wheel for 1.5mm
|
|
|
|
lcd_implementation_clear();
|
|
|
|
lcd_z_offset_edit_setup(measured_z);
|
|
|
|
|
|
|
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
|
|
|
|
|
|
|
do {
|
|
|
|
measured_z = lcd_z_offset_edit();
|
|
|
|
idle();
|
|
|
|
do_blocking_move_to_z(measured_z);
|
|
|
|
} while (!ubl_lcd_clicked());
|
|
|
|
|
|
|
|
ubl.has_control_of_lcd_panel++; // There is a race condition for the Encoder Wheel getting clicked.
|
|
|
|
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune)
|
|
|
|
// or here. So, until we are done looking for a long Encoder Wheel Press,
|
|
|
|
// we need to take control of the panel
|
|
|
|
|
|
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
|
|
|
|
|
|
lcd_return_to_status();
|
|
|
|
|
|
|
|
const millis_t nxt = millis() + 1500UL;
|
|
|
|
while (ubl_lcd_clicked()) { // debounce and watch for abort
|
|
|
|
idle();
|
|
|
|
if (ELAPSED(millis(), nxt)) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("\nZ-Offset Adjustment Stopped.");
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
|
|
|
lcd_setstatus("Z-Offset Stopped", true);
|
|
|
|
restore_ubl_active_state_and_leave();
|
|
|
|
goto LEAVE;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
ubl.has_control_of_lcd_panel = false;
|
|
|
|
safe_delay(20); // We don't want any switch noise.
|
|
|
|
|
|
|
|
ubl.state.z_offset = measured_z;
|
|
|
|
|
|
|
|
lcd_implementation_clear();
|
|
|
|
restore_ubl_active_state_and_leave();
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
LEAVE:
|
|
|
|
|
|
|
|
#if ENABLED(ULTRA_LCD)
|
|
|
|
lcd_setstatus(" ", true);
|
|
|
|
lcd_quick_feedback();
|
|
|
|
#endif
|
|
|
|
|
|
|
|
ubl.has_control_of_lcd_panel = false;
|
|
|
|
}
|
|
|
|
|
|
|
|
void find_mean_mesh_height() {
|
|
|
|
uint8_t x, y;
|
|
|
|
int n;
|
|
|
|
float sum, sum_of_diff_squared, sigma, difference, mean;
|
|
|
|
|
|
|
|
sum = sum_of_diff_squared = 0.0;
|
|
|
|
n = 0;
|
|
|
|
for (x = 0; x < UBL_MESH_NUM_X_POINTS; x++)
|
|
|
|
for (y = 0; y < UBL_MESH_NUM_Y_POINTS; y++)
|
|
|
|
if (!isnan(ubl.z_values[x][y])) {
|
|
|
|
sum += ubl.z_values[x][y];
|
|
|
|
n++;
|
|
|
|
}
|
|
|
|
|
|
|
|
mean = sum / n;
|
|
|
|
|
|
|
|
//
|
|
|
|
// Now do the sumation of the squares of difference from mean
|
|
|
|
//
|
|
|
|
for (x = 0; x < UBL_MESH_NUM_X_POINTS; x++)
|
|
|
|
for (y = 0; y < UBL_MESH_NUM_Y_POINTS; y++)
|
|
|
|
if (!isnan(ubl.z_values[x][y])) {
|
|
|
|
difference = (ubl.z_values[x][y] - mean);
|
|
|
|
sum_of_diff_squared += difference * difference;
|
|
|
|
}
|
|
|
|
|
|
|
|
SERIAL_ECHOLNPAIR("# of samples: ", n);
|
|
|
|
SERIAL_ECHOPGM("Mean Mesh Height: ");
|
|
|
|
SERIAL_ECHO_F(mean, 6);
|
|
|
|
SERIAL_EOL;
|
|
|
|
|
|
|
|
sigma = sqrt(sum_of_diff_squared / (n + 1));
|
|
|
|
SERIAL_ECHOPGM("Standard Deviation: ");
|
|
|
|
SERIAL_ECHO_F(sigma, 6);
|
|
|
|
SERIAL_EOL;
|
|
|
|
|
|
|
|
if (c_flag)
|
|
|
|
for (x = 0; x < UBL_MESH_NUM_X_POINTS; x++)
|
|
|
|
for (y = 0; y < UBL_MESH_NUM_Y_POINTS; y++)
|
|
|
|
if (!isnan(ubl.z_values[x][y]))
|
|
|
|
ubl.z_values[x][y] -= mean + ubl_constant;
|
|
|
|
}
|
|
|
|
|
|
|
|
void shift_mesh_height() {
|
|
|
|
for (uint8_t x = 0; x < UBL_MESH_NUM_X_POINTS; x++)
|
|
|
|
for (uint8_t y = 0; y < UBL_MESH_NUM_Y_POINTS; y++)
|
|
|
|
if (!isnan(ubl.z_values[x][y]))
|
|
|
|
ubl.z_values[x][y] += ubl_constant;
|
|
|
|
}
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Probe all invalidated locations of the mesh that can be reached by the probe.
|
|
|
|
* This attempts to fill in locations closest to the nozzle's start location first.
|
|
|
|
*/
|
|
|
|
void probe_entire_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map, const bool stow_probe, bool do_furthest) {
|
|
|
|
mesh_index_pair location;
|
|
|
|
|
|
|
|
ubl.has_control_of_lcd_panel++;
|
|
|
|
save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
|
|
|
|
DEPLOY_PROBE();
|
|
|
|
|
|
|
|
do {
|
|
|
|
if (ubl_lcd_clicked()) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.\n");
|
|
|
|
lcd_quick_feedback();
|
|
|
|
STOW_PROBE();
|
|
|
|
while (ubl_lcd_clicked()) idle();
|
|
|
|
ubl.has_control_of_lcd_panel = false;
|
|
|
|
restore_ubl_active_state_and_leave();
|
|
|
|
safe_delay(50); // Debounce the Encoder wheel
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
location = find_closest_mesh_point_of_type(INVALID, lx, ly, 1, NULL, do_furthest ); // the '1' says we want the location to be relative to the probe
|
|
|
|
if (location.x_index >= 0 && location.y_index >= 0) {
|
|
|
|
|
|
|
|
const float rawx = ubl.mesh_index_to_xpos[location.x_index],
|
|
|
|
rawy = ubl.mesh_index_to_ypos[location.y_index];
|
|
|
|
|
|
|
|
// TODO: Change to use `position_is_reachable` (for SCARA-compatibility)
|
|
|
|
if (rawx < (MIN_PROBE_X) || rawx > (MAX_PROBE_X) || rawy < (MIN_PROBE_Y) || rawy > (MAX_PROBE_Y)) {
|
|
|
|
SERIAL_ERROR_START;
|
|
|
|
SERIAL_ERRORLNPGM("Attempt to probe off the bed.");
|
|
|
|
ubl.has_control_of_lcd_panel = false;
|
|
|
|
goto LEAVE;
|
|
|
|
}
|
|
|
|
const float measured_z = probe_pt(LOGICAL_X_POSITION(rawx), LOGICAL_Y_POSITION(rawy), stow_probe, g29_verbose_level);
|
|
|
|
ubl.z_values[location.x_index][location.y_index] = measured_z + zprobe_zoffset;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (do_ubl_mesh_map) ubl.display_map(map_type);
|
|
|
|
|
|
|
|
} while (location.x_index >= 0 && location.y_index >= 0);
|
|
|
|
|
|
|
|
LEAVE:
|
|
|
|
|
|
|
|
STOW_PROBE();
|
|
|
|
restore_ubl_active_state_and_leave();
|
|
|
|
|
|
|
|
do_blocking_move_to_xy(
|
|
|
|
constrain(lx - (X_PROBE_OFFSET_FROM_EXTRUDER), X_MIN_POS, X_MAX_POS),
|
|
|
|
constrain(ly - (Y_PROBE_OFFSET_FROM_EXTRUDER), Y_MIN_POS, Y_MAX_POS)
|
|
|
|
);
|
|
|
|
}
|
|
|
|
|
|
|
|
vector_3 tilt_mesh_based_on_3pts(const float &pt1, const float &pt2, const float &pt3) {
|
|
|
|
float c, d, t;
|
|
|
|
int i, j;
|
|
|
|
|
|
|
|
vector_3 v1 = vector_3( (ubl_3_point_1_X - ubl_3_point_2_X),
|
|
|
|
(ubl_3_point_1_Y - ubl_3_point_2_Y),
|
|
|
|
(pt1 - pt2) ),
|
|
|
|
|
|
|
|
v2 = vector_3( (ubl_3_point_3_X - ubl_3_point_2_X),
|
|
|
|
(ubl_3_point_3_Y - ubl_3_point_2_Y),
|
|
|
|
(pt3 - pt2) ),
|
|
|
|
|
|
|
|
normal = vector_3::cross(v1, v2);
|
|
|
|
|
|
|
|
// printf("[%f,%f,%f] ", normal.x, normal.y, normal.z);
|
|
|
|
|
|
|
|
/**
|
|
|
|
* This code does two things. This vector is normal to the tilted plane.
|
|
|
|
* However, we don't know its direction. We need it to point up. So if
|
|
|
|
* Z is negative, we need to invert the sign of all components of the vector
|
|
|
|
* We also need Z to be unity because we are going to be treating this triangle
|
|
|
|
* as the sin() and cos() of the bed's tilt
|
|
|
|
*/
|
|
|
|
const float inv_z = 1.0 / normal.z;
|
|
|
|
normal.x *= inv_z;
|
|
|
|
normal.y *= inv_z;
|
|
|
|
normal.z = 1.0;
|
|
|
|
|
|
|
|
//
|
|
|
|
// All of 3 of these points should give us the same d constant
|
|
|
|
//
|
|
|
|
t = normal.x * ubl_3_point_1_X + normal.y * ubl_3_point_1_Y;
|
|
|
|
d = t + normal.z * pt1;
|
|
|
|
c = d - t;
|
|
|
|
SERIAL_ECHOPGM("d from 1st point: ");
|
|
|
|
SERIAL_ECHO_F(d, 6);
|
|
|
|
SERIAL_ECHOPGM(" c: ");
|
|
|
|
SERIAL_ECHO_F(c, 6);
|
|
|
|
SERIAL_EOL;
|
|
|
|
t = normal.x * ubl_3_point_2_X + normal.y * ubl_3_point_2_Y;
|
|
|
|
d = t + normal.z * pt2;
|
|
|
|
c = d - t;
|
|
|
|
SERIAL_ECHOPGM("d from 2nd point: ");
|
|
|
|
SERIAL_ECHO_F(d, 6);
|
|
|
|
SERIAL_ECHOPGM(" c: ");
|
|
|
|
SERIAL_ECHO_F(c, 6);
|
|
|
|
SERIAL_EOL;
|
|
|
|
t = normal.x * ubl_3_point_3_X + normal.y * ubl_3_point_3_Y;
|
|
|
|
d = t + normal.z * pt3;
|
|
|
|
c = d - t;
|
|
|
|
SERIAL_ECHOPGM("d from 3rd point: ");
|
|
|
|
SERIAL_ECHO_F(d, 6);
|
|
|
|
SERIAL_ECHOPGM(" c: ");
|
|
|
|
SERIAL_ECHO_F(c, 6);
|
|
|
|
SERIAL_EOL;
|
|
|
|
|
|
|
|
for (i = 0; i < UBL_MESH_NUM_X_POINTS; i++) {
|
|
|
|
for (j = 0; j < UBL_MESH_NUM_Y_POINTS; j++) {
|
|
|
|
c = -((normal.x * (UBL_MESH_MIN_X + i * (MESH_X_DIST)) + normal.y * (UBL_MESH_MIN_Y + j * (MESH_Y_DIST))) - d);
|
|
|
|
ubl.z_values[i][j] += c;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
return normal;
|
|
|
|
}
|
|
|
|
|
|
|
|
float use_encoder_wheel_to_measure_point() {
|
|
|
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
|
|
|
while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here!
|
|
|
|
idle();
|
|
|
|
if (ubl.encoder_diff) {
|
|
|
|
do_blocking_move_to_z(current_position[Z_AXIS] + 0.01 * float(ubl.encoder_diff));
|
|
|
|
ubl.encoder_diff = 0;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
|
|
return current_position[Z_AXIS];
|
|
|
|
}
|
|
|
|
|
|
|
|
float measure_business_card_thickness(const float &in_height) {
|
|
|
|
|
|
|
|
ubl.has_control_of_lcd_panel++;
|
|
|
|
save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLLNPGM("Place Shim Under Nozzle and Perform Measurement.");
|
|
|
|
do_blocking_move_to_z(in_height);
|
|
|
|
do_blocking_move_to_xy((float(X_MAX_POS) - float(X_MIN_POS)) / 2.0, (float(Y_MAX_POS) - float(Y_MIN_POS)) / 2.0);
|
|
|
|
//, min( planner.max_feedrate_mm_s[X_AXIS], planner.max_feedrate_mm_s[Y_AXIS])/2.0);
|
|
|
|
|
|
|
|
const float z1 = use_encoder_wheel_to_measure_point();
|
|
|
|
do_blocking_move_to_z(current_position[Z_AXIS] + SIZE_OF_LITTLE_RAISE);
|
|
|
|
ubl.has_control_of_lcd_panel = false;
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLLNPGM("Remove Shim and Measure Bed Height.");
|
|
|
|
const float z2 = use_encoder_wheel_to_measure_point();
|
|
|
|
do_blocking_move_to_z(current_position[Z_AXIS] + SIZE_OF_LITTLE_RAISE);
|
|
|
|
|
|
|
|
if (g29_verbose_level > 1) {
|
|
|
|
SERIAL_PROTOCOLPGM("Business Card is: ");
|
|
|
|
SERIAL_PROTOCOL_F(abs(z1 - z2), 6);
|
|
|
|
SERIAL_PROTOCOLLNPGM("mm thick.");
|
|
|
|
}
|
|
|
|
restore_ubl_active_state_and_leave();
|
|
|
|
return abs(z1 - z2);
|
|
|
|
}
|
|
|
|
|
|
|
|
void manually_probe_remaining_mesh(const float &lx, const float &ly, const float &z_clearance, const float &card_thickness, const bool do_ubl_mesh_map) {
|
|
|
|
|
|
|
|
ubl.has_control_of_lcd_panel++;
|
|
|
|
save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe
|
|
|
|
do_blocking_move_to_z(z_clearance);
|
|
|
|
do_blocking_move_to_xy(lx, ly);
|
|
|
|
|
|
|
|
float last_x = -9999.99, last_y = -9999.99;
|
|
|
|
mesh_index_pair location;
|
|
|
|
do {
|
|
|
|
if (do_ubl_mesh_map) ubl.display_map(map_type);
|
|
|
|
|
|
|
|
location = find_closest_mesh_point_of_type(INVALID, lx, ly, 0, NULL, false); // The '0' says we want to use the nozzle's position
|
|
|
|
// It doesn't matter if the probe can't reach the NAN location. This is a manual probe.
|
|
|
|
if (location.x_index < 0 && location.y_index < 0) continue;
|
|
|
|
|
|
|
|
const float rawx = ubl.mesh_index_to_xpos[location.x_index],
|
|
|
|
rawy = ubl.mesh_index_to_ypos[location.y_index];
|
|
|
|
|
|
|
|
// TODO: Change to use `position_is_reachable` (for SCARA-compatibility)
|
|
|
|
if (rawx < (X_MIN_POS) || rawx > (X_MAX_POS) || rawy < (Y_MIN_POS) || rawy > (Y_MAX_POS)) {
|
|
|
|
SERIAL_ERROR_START;
|
|
|
|
SERIAL_ERRORLNPGM("Attempt to probe off the bed.");
|
|
|
|
ubl.has_control_of_lcd_panel = false;
|
|
|
|
goto LEAVE;
|
|
|
|
}
|
|
|
|
|
|
|
|
const float xProbe = LOGICAL_X_POSITION(rawx),
|
|
|
|
yProbe = LOGICAL_Y_POSITION(rawy),
|
|
|
|
dx = xProbe - last_x,
|
|
|
|
dy = yProbe - last_y;
|
|
|
|
|
|
|
|
if (HYPOT(dx, dy) < BIG_RAISE_NOT_NEEDED)
|
|
|
|
do_blocking_move_to_z(current_position[Z_AXIS] + SIZE_OF_LITTLE_RAISE);
|
|
|
|
else
|
|
|
|
do_blocking_move_to_z(z_clearance);
|
|
|
|
|
|
|
|
do_blocking_move_to_xy(xProbe, yProbe);
|
|
|
|
|
|
|
|
last_x = xProbe;
|
|
|
|
last_y = yProbe;
|
|
|
|
|
|
|
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
|
|
|
ubl.has_control_of_lcd_panel = true;
|
|
|
|
|
|
|
|
while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here!
|
|
|
|
idle();
|
|
|
|
if (ubl.encoder_diff) {
|
|
|
|
do_blocking_move_to_z(current_position[Z_AXIS] + float(ubl.encoder_diff) / 100.0);
|
|
|
|
ubl.encoder_diff = 0;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
const millis_t nxt = millis() + 1500L;
|
|
|
|
while (ubl_lcd_clicked()) { // debounce and watch for abort
|
|
|
|
idle();
|
|
|
|
if (ELAPSED(millis(), nxt)) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.");
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
|
|
|
lcd_quick_feedback();
|
|
|
|
while (ubl_lcd_clicked()) idle();
|
|
|
|
ubl.has_control_of_lcd_panel = false;
|
|
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
|
|
restore_ubl_active_state_and_leave();
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
ubl.z_values[location.x_index][location.y_index] = current_position[Z_AXIS] - card_thickness;
|
|
|
|
if (g29_verbose_level > 2) {
|
|
|
|
SERIAL_PROTOCOLPGM("Mesh Point Measured at: ");
|
|
|
|
SERIAL_PROTOCOL_F(ubl.z_values[location.x_index][location.y_index], 6);
|
|
|
|
SERIAL_EOL;
|
|
|
|
}
|
|
|
|
} while (location.x_index >= 0 && location.y_index >= 0);
|
|
|
|
|
|
|
|
if (do_ubl_mesh_map) ubl.display_map(map_type);
|
|
|
|
|
|
|
|
LEAVE:
|
|
|
|
restore_ubl_active_state_and_leave();
|
|
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
|
|
|
do_blocking_move_to_xy(lx, ly);
|
|
|
|
}
|
|
|
|
|
|
|
|
bool g29_parameter_parsing() {
|
|
|
|
#if ENABLED(ULTRA_LCD)
|
|
|
|
lcd_setstatus("Doing G29 UBL !", true);
|
|
|
|
lcd_quick_feedback();
|
|
|
|
#endif
|
|
|
|
|
|
|
|
g29_verbose_level = code_seen('V') ? code_value_int() : 0;
|
|
|
|
if (g29_verbose_level < 0 || g29_verbose_level > 4) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("Invalid Verbose Level specified. (0-4)\n");
|
|
|
|
return UBL_ERR;
|
|
|
|
}
|
|
|
|
|
|
|
|
x_flag = code_seen('X') && code_has_value();
|
|
|
|
x_pos = x_flag ? code_value_float() : current_position[X_AXIS];
|
|
|
|
if (x_pos < LOGICAL_X_POSITION(X_MIN_POS) || x_pos > LOGICAL_X_POSITION(X_MAX_POS)) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("Invalid X location specified.\n");
|
|
|
|
return UBL_ERR;
|
|
|
|
}
|
|
|
|
|
|
|
|
y_flag = code_seen('Y') && code_has_value();
|
|
|
|
y_pos = y_flag ? code_value_float() : current_position[Y_AXIS];
|
|
|
|
if (y_pos < LOGICAL_Y_POSITION(Y_MIN_POS) || y_pos > LOGICAL_Y_POSITION(Y_MAX_POS)) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("Invalid Y location specified.\n");
|
|
|
|
return UBL_ERR;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (x_flag != y_flag) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("Both X & Y locations must be specified.\n");
|
|
|
|
return UBL_ERR;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (code_seen('A')) { // Activate the Unified Bed Leveling System
|
|
|
|
ubl.state.active = 1;
|
|
|
|
SERIAL_PROTOCOLLNPGM("Unified Bed Leveling System activated.\n");
|
|
|
|
ubl.store_state();
|
|
|
|
}
|
|
|
|
|
|
|
|
c_flag = code_seen('C') && code_has_value();
|
|
|
|
ubl_constant = c_flag ? code_value_float() : 0.0;
|
|
|
|
|
|
|
|
if (code_seen('D')) { // Disable the Unified Bed Leveling System
|
|
|
|
ubl.state.active = 0;
|
|
|
|
SERIAL_PROTOCOLLNPGM("Unified Bed Leveling System de-activated.\n");
|
|
|
|
ubl.store_state();
|
|
|
|
}
|
|
|
|
|
|
|
|
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
|
|
|
if (code_seen('F') && code_has_value()) {
|
|
|
|
const float fh = code_value_float();
|
|
|
|
if (fh < 0.0 || fh > 100.0) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("?Bed Level Correction Fade Height Not Plausible.\n");
|
|
|
|
return UBL_ERR;
|
|
|
|
}
|
|
|
|
ubl.state.g29_correction_fade_height = fh;
|
|
|
|
ubl.state.g29_fade_height_multiplier = 1.0 / fh;
|
|
|
|
}
|
|
|
|
#endif
|
|
|
|
|
|
|
|
repeat_flag = code_seen('R');
|
|
|
|
repetition_cnt = repeat_flag ? (code_has_value() ? code_value_int() : 9999) : 1;
|
|
|
|
if (repetition_cnt < 1) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("Invalid Repetition count.\n");
|
|
|
|
return UBL_ERR;
|
|
|
|
}
|
|
|
|
|
|
|
|
map_type = code_seen('O') && code_has_value() ? code_value_int() : 0;
|
|
|
|
if (map_type < 0 || map_type > 1) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("Invalid map type.\n");
|
|
|
|
return UBL_ERR;
|
|
|
|
}
|
|
|
|
|
|
|
|
/*
|
|
|
|
if (code_seen('M')) { // Check if a map type was specified
|
|
|
|
map_type = code_has_value() ? code_value_int() : 0;
|
|
|
|
if (map_type < 0 || map_type > 1) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("Invalid map type.\n");
|
|
|
|
return UBL_ERR;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
//*/
|
|
|
|
|
|
|
|
return UBL_OK;
|
|
|
|
}
|
|
|
|
|
|
|
|
/**
|
|
|
|
* This function goes away after G29 debug is complete. But for right now, it is a handy
|
|
|
|
* routine to dump binary data structures.
|
|
|
|
*/
|
|
|
|
void dump(char * const str, const float &f) {
|
|
|
|
char *ptr;
|
|
|
|
|
|
|
|
SERIAL_PROTOCOL(str);
|
|
|
|
SERIAL_PROTOCOL_F(f, 8);
|
|
|
|
SERIAL_PROTOCOLPGM(" ");
|
|
|
|
ptr = (char*)&f;
|
|
|
|
for (uint8_t i = 0; i < 4; i++)
|
|
|
|
SERIAL_PROTOCOLPAIR(" ", hex_byte(*ptr++));
|
|
|
|
SERIAL_PROTOCOLPAIR(" isnan()=", isnan(f));
|
|
|
|
SERIAL_PROTOCOLPAIR(" isinf()=", isinf(f));
|
|
|
|
|
|
|
|
if (f == -INFINITY)
|
|
|
|
SERIAL_PROTOCOLPGM(" Minus Infinity detected.");
|
|
|
|
|
|
|
|
SERIAL_EOL;
|
|
|
|
}
|
|
|
|
|
|
|
|
static int ubl_state_at_invocation = 0,
|
|
|
|
ubl_state_recursion_chk = 0;
|
|
|
|
|
|
|
|
void save_ubl_active_state_and_disable() {
|
|
|
|
ubl_state_recursion_chk++;
|
|
|
|
if (ubl_state_recursion_chk != 1) {
|
|
|
|
SERIAL_ECHOLNPGM("save_ubl_active_state_and_disabled() called multiple times in a row.");
|
|
|
|
lcd_setstatus("save_UBL_active() error", true);
|
|
|
|
lcd_quick_feedback();
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
ubl_state_at_invocation = ubl.state.active;
|
|
|
|
ubl.state.active = 0;
|
|
|
|
}
|
|
|
|
|
|
|
|
void restore_ubl_active_state_and_leave() {
|
|
|
|
if (--ubl_state_recursion_chk) {
|
|
|
|
SERIAL_ECHOLNPGM("restore_ubl_active_state_and_leave() called too many times.");
|
|
|
|
lcd_setstatus("restore_UBL_active() error", true);
|
|
|
|
lcd_quick_feedback();
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
ubl.state.active = ubl_state_at_invocation;
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
* Much of the 'What?' command can be eliminated. But until we are fully debugged, it is
|
|
|
|
* good to have the extra information. Soon... we prune this to just a few items
|
|
|
|
*/
|
|
|
|
void g29_what_command() {
|
|
|
|
const uint16_t k = E2END - ubl.eeprom_start;
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLPGM("Unified Bed Leveling System Version 1.00 ");
|
|
|
|
if (ubl.state.active)
|
|
|
|
SERIAL_PROTOCOLCHAR('A');
|
|
|
|
else
|
|
|
|
SERIAL_PROTOCOLPGM("In");
|
|
|
|
SERIAL_PROTOCOLLNPGM("ctive.\n");
|
|
|
|
safe_delay(50);
|
|
|
|
|
|
|
|
if (ubl.state.eeprom_storage_slot == -1)
|
|
|
|
SERIAL_PROTOCOLPGM("No Mesh Loaded.");
|
|
|
|
else {
|
|
|
|
SERIAL_PROTOCOLPAIR("Mesh ", ubl.state.eeprom_storage_slot);
|
|
|
|
SERIAL_PROTOCOLPGM(" Loaded.");
|
|
|
|
}
|
|
|
|
SERIAL_EOL;
|
|
|
|
safe_delay(50);
|
|
|
|
|
|
|
|
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
|
|
|
SERIAL_PROTOCOLPAIR("g29_correction_fade_height : ", ubl.state.g29_correction_fade_height);
|
|
|
|
SERIAL_EOL;
|
|
|
|
#endif
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLPGM("z_offset: ");
|
|
|
|
SERIAL_PROTOCOL_F(ubl.state.z_offset, 6);
|
|
|
|
SERIAL_EOL;
|
|
|
|
safe_delay(50);
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLPGM("X-Axis Mesh Points at: ");
|
|
|
|
for (uint8_t i = 0; i < UBL_MESH_NUM_X_POINTS; i++) {
|
|
|
|
SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(ubl.mesh_index_to_xpos[i]), 1);
|
|
|
|
SERIAL_PROTOCOLPGM(" ");
|
|
|
|
safe_delay(50);
|
|
|
|
}
|
|
|
|
SERIAL_EOL;
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLPGM("Y-Axis Mesh Points at: ");
|
|
|
|
for (uint8_t i = 0; i < UBL_MESH_NUM_Y_POINTS; i++) {
|
|
|
|
SERIAL_PROTOCOL_F(LOGICAL_Y_POSITION(ubl.mesh_index_to_ypos[i]), 1);
|
|
|
|
SERIAL_PROTOCOLPGM(" ");
|
|
|
|
safe_delay(50);
|
|
|
|
}
|
|
|
|
SERIAL_EOL;
|
|
|
|
|
|
|
|
#if HAS_KILL
|
|
|
|
SERIAL_PROTOCOLPAIR("Kill pin on :", KILL_PIN);
|
|
|
|
SERIAL_PROTOCOLLNPAIR(" state:", READ(KILL_PIN));
|
|
|
|
#endif
|
|
|
|
SERIAL_EOL;
|
|
|
|
safe_delay(50);
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLLNPAIR("ubl_state_at_invocation :", ubl_state_at_invocation);
|
|
|
|
SERIAL_EOL;
|
|
|
|
SERIAL_PROTOCOLLNPAIR("ubl_state_recursion_chk :", ubl_state_recursion_chk);
|
|
|
|
SERIAL_EOL;
|
|
|
|
safe_delay(50);
|
|
|
|
SERIAL_PROTOCOLLNPAIR("Free EEPROM space starts at: 0x", hex_word(ubl.eeprom_start));
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLLNPAIR("end of EEPROM : 0x", hex_word(E2END));
|
|
|
|
safe_delay(50);
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLLNPAIR("sizeof(ubl) : ", (int)sizeof(ubl));
|
|
|
|
SERIAL_EOL;
|
|
|
|
SERIAL_PROTOCOLLNPAIR("z_value[][] size: ", (int)sizeof(ubl.z_values));
|
|
|
|
SERIAL_EOL;
|
|
|
|
safe_delay(50);
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLLNPAIR("EEPROM free for UBL: 0x", hex_word(k));
|
|
|
|
safe_delay(50);
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLPAIR("EEPROM can hold ", k / sizeof(ubl.z_values));
|
|
|
|
SERIAL_PROTOCOLLNPGM(" meshes.\n");
|
|
|
|
safe_delay(50);
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLPAIR("sizeof(ubl.state) : ", (int)sizeof(ubl.state));
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLPAIR("\nUBL_MESH_NUM_X_POINTS ", UBL_MESH_NUM_X_POINTS);
|
|
|
|
SERIAL_PROTOCOLPAIR("\nUBL_MESH_NUM_Y_POINTS ", UBL_MESH_NUM_Y_POINTS);
|
|
|
|
safe_delay(50);
|
|
|
|
SERIAL_PROTOCOLPAIR("\nUBL_MESH_MIN_X ", UBL_MESH_MIN_X);
|
|
|
|
SERIAL_PROTOCOLPAIR("\nUBL_MESH_MIN_Y ", UBL_MESH_MIN_Y);
|
|
|
|
safe_delay(50);
|
|
|
|
SERIAL_PROTOCOLPAIR("\nUBL_MESH_MAX_X ", UBL_MESH_MAX_X);
|
|
|
|
SERIAL_PROTOCOLPAIR("\nUBL_MESH_MAX_Y ", UBL_MESH_MAX_Y);
|
|
|
|
safe_delay(50);
|
|
|
|
SERIAL_PROTOCOLPGM("\nMESH_X_DIST ");
|
|
|
|
SERIAL_PROTOCOL_F(MESH_X_DIST, 6);
|
|
|
|
SERIAL_PROTOCOLPGM("\nMESH_Y_DIST ");
|
|
|
|
SERIAL_PROTOCOL_F(MESH_Y_DIST, 6);
|
|
|
|
SERIAL_EOL;
|
|
|
|
safe_delay(50);
|
|
|
|
|
|
|
|
if (!ubl.sanity_check())
|
|
|
|
SERIAL_PROTOCOLLNPGM("Unified Bed Leveling sanity checks passed.");
|
|
|
|
}
|
|
|
|
|
|
|
|
/**
|
|
|
|
* When we are fully debugged, the EEPROM dump command will get deleted also. But
|
|
|
|
* right now, it is good to have the extra information. Soon... we prune this.
|
|
|
|
*/
|
|
|
|
void g29_eeprom_dump() {
|
|
|
|
unsigned char cccc;
|
|
|
|
uint16_t kkkk;
|
|
|
|
|
|
|
|
SERIAL_ECHO_START;
|
|
|
|
SERIAL_ECHOLNPGM("EEPROM Dump:");
|
|
|
|
for (uint16_t i = 0; i < E2END + 1; i += 16) {
|
|
|
|
if (!(i & 0x3)) idle();
|
|
|
|
print_hex_word(i);
|
|
|
|
SERIAL_ECHOPGM(": ");
|
|
|
|
for (uint16_t j = 0; j < 16; j++) {
|
|
|
|
kkkk = i + j;
|
|
|
|
eeprom_read_block(&cccc, (void *)kkkk, 1);
|
|
|
|
print_hex_byte(cccc);
|
|
|
|
SERIAL_ECHO(' ');
|
|
|
|
}
|
|
|
|
SERIAL_EOL;
|
|
|
|
}
|
|
|
|
SERIAL_EOL;
|
|
|
|
}
|
|
|
|
|
|
|
|
/**
|
|
|
|
* When we are fully debugged, this may go away. But there are some valid
|
|
|
|
* use cases for the users. So we can wait and see what to do with it.
|
|
|
|
*/
|
|
|
|
void g29_compare_current_mesh_to_stored_mesh() {
|
|
|
|
float tmp_z_values[UBL_MESH_NUM_X_POINTS][UBL_MESH_NUM_Y_POINTS];
|
|
|
|
|
|
|
|
if (!code_has_value()) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("?Mesh # required.\n");
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
storage_slot = code_value_int();
|
|
|
|
|
|
|
|
int16_t j = (UBL_LAST_EEPROM_INDEX - ubl.eeprom_start) / sizeof(tmp_z_values);
|
|
|
|
|
|
|
|
if (storage_slot < 0 || storage_slot > j || ubl.eeprom_start <= 0) {
|
|
|
|
SERIAL_PROTOCOLLNPGM("?EEPROM storage not available for use.\n");
|
|
|
|
return;
|
|
|
|
}
|
|
|
|
|
|
|
|
j = UBL_LAST_EEPROM_INDEX - (storage_slot + 1) * sizeof(tmp_z_values);
|
|
|
|
eeprom_read_block((void *)&tmp_z_values, (void *)j, sizeof(tmp_z_values));
|
|
|
|
|
|
|
|
SERIAL_ECHOPAIR("Subtracting Mesh ", storage_slot);
|
|
|
|
SERIAL_PROTOCOLLNPAIR(" loaded from EEPROM address 0x", hex_word(j)); // Soon, we can remove the extra clutter of printing
|
|
|
|
// the address in the EEPROM where the Mesh is stored.
|
|
|
|
|
|
|
|
for (uint8_t x = 0; x < UBL_MESH_NUM_X_POINTS; x++)
|
|
|
|
for (uint8_t y = 0; y < UBL_MESH_NUM_Y_POINTS; y++)
|
|
|
|
ubl.z_values[x][y] -= tmp_z_values[x][y];
|
|
|
|
}
|
|
|
|
|
|
|
|
mesh_index_pair find_closest_mesh_point_of_type(const MeshPointType type, const float &lx, const float &ly, const bool probe_as_reference, unsigned int bits[16], bool far_flag) {
|
|
|
|
float distance, closest = far_flag ? -99999.99 : 99999.99;
|
|
|
|
mesh_index_pair return_val;
|
|
|
|
|
|
|
|
return_val.x_index = return_val.y_index = -1;
|
|
|
|
|
|
|
|
const float current_x = current_position[X_AXIS],
|
|
|
|
current_y = current_position[Y_AXIS];
|
|
|
|
|
|
|
|
// Get our reference position. Either the nozzle or probe location.
|
|
|
|
const float px = lx - (probe_as_reference ? X_PROBE_OFFSET_FROM_EXTRUDER : 0),
|
|
|
|
py = ly - (probe_as_reference ? Y_PROBE_OFFSET_FROM_EXTRUDER : 0);
|
|
|
|
|
|
|
|
for (uint8_t i = 0; i < UBL_MESH_NUM_X_POINTS; i++) {
|
|
|
|
for (uint8_t j = 0; j < UBL_MESH_NUM_Y_POINTS; j++) {
|
|
|
|
|
|
|
|
if ( (type == INVALID && isnan(ubl.z_values[i][j])) // Check to see if this location holds the right thing
|
|
|
|
|| (type == REAL && !isnan(ubl.z_values[i][j]))
|
|
|
|
|| (type == SET_IN_BITMAP && is_bit_set(bits, i, j))
|
|
|
|
) {
|
|
|
|
|
|
|
|
// We only get here if we found a Mesh Point of the specified type
|
|
|
|
|
|
|
|
const float rawx = ubl.mesh_index_to_xpos[i], // Check if we can probe this mesh location
|
|
|
|
rawy = ubl.mesh_index_to_ypos[j];
|
|
|
|
|
|
|
|
// If using the probe as the reference there are some unreachable locations.
|
|
|
|
// Prune them from the list and ignore them till the next Phase (manual nozzle probing).
|
|
|
|
|
|
|
|
if (probe_as_reference &&
|
|
|
|
(rawx < (MIN_PROBE_X) || rawx > (MAX_PROBE_X) || rawy < (MIN_PROBE_Y) || rawy > (MAX_PROBE_Y))
|
|
|
|
) continue;
|
|
|
|
|
|
|
|
// Unreachable. Check if it's the closest location to the nozzle.
|
|
|
|
// Add in a weighting factor that considers the current location of the nozzle.
|
|
|
|
|
|
|
|
const float mx = LOGICAL_X_POSITION(rawx), // Check if we can probe this mesh location
|
|
|
|
my = LOGICAL_Y_POSITION(rawy);
|
|
|
|
|
|
|
|
distance = HYPOT(px - mx, py - my) + HYPOT(current_x - mx, current_y - my) * 0.1;
|
|
|
|
|
|
|
|
if (far_flag) { // If doing the far_flag action, we want to be as far as possible
|
|
|
|
for (uint8_t k = 0; k < UBL_MESH_NUM_X_POINTS; k++) { // from the starting point and from any other probed points. We
|
|
|
|
for (uint8_t l = 0; l < UBL_MESH_NUM_Y_POINTS; l++) { // want the next point spread out and filling in any blank spaces
|
|
|
|
if (!isnan(ubl.z_values[k][l])) { // in the mesh. So we add in some of the distance to every probed
|
|
|
|
distance += sq(i - k) * (MESH_X_DIST) * .05 // point we can find.
|
|
|
|
+ sq(j - l) * (MESH_Y_DIST) * .05;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
if (far_flag == (distance > closest) && distance != closest) { // if far_flag, look for farthest point
|
|
|
|
closest = distance; // We found a closer/farther location with
|
|
|
|
return_val.x_index = i; // the specified type of mesh value.
|
|
|
|
return_val.y_index = j;
|
|
|
|
return_val.distance = closest;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
} // for j
|
|
|
|
} // for i
|
|
|
|
|
|
|
|
return return_val;
|
|
|
|
}
|
|
|
|
|
|
|
|
void fine_tune_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map) {
|
|
|
|
mesh_index_pair location;
|
|
|
|
uint16_t not_done[16];
|
|
|
|
int32_t round_off;
|
|
|
|
|
|
|
|
save_ubl_active_state_and_disable();
|
|
|
|
memset(not_done, 0xFF, sizeof(not_done));
|
|
|
|
|
|
|
|
#if ENABLED(ULTRA_LCD)
|
|
|
|
lcd_setstatus("Fine Tuning Mesh.", true);
|
|
|
|
#endif
|
|
|
|
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
|
|
|
do_blocking_move_to_xy(lx, ly);
|
|
|
|
do {
|
|
|
|
if (do_ubl_mesh_map) ubl.display_map(map_type);
|
|
|
|
|
|
|
|
location = find_closest_mesh_point_of_type( SET_IN_BITMAP, lx, ly, 0, not_done, false); // The '0' says we want to use the nozzle's position
|
|
|
|
// It doesn't matter if the probe can not reach this
|
|
|
|
// location. This is a manual edit of the Mesh Point.
|
|
|
|
if (location.x_index < 0 && location.y_index < 0) continue; // abort if we can't find any more points.
|
|
|
|
|
|
|
|
bit_clear(not_done, location.x_index, location.y_index); // Mark this location as 'adjusted' so we will find a
|
|
|
|
// different location the next time through the loop
|
|
|
|
|
|
|
|
const float rawx = ubl.mesh_index_to_xpos[location.x_index],
|
|
|
|
rawy = ubl.mesh_index_to_ypos[location.y_index];
|
|
|
|
|
|
|
|
// TODO: Change to use `position_is_reachable` (for SCARA-compatibility)
|
|
|
|
if (rawx < (X_MIN_POS) || rawx > (X_MAX_POS) || rawy < (Y_MIN_POS) || rawy > (Y_MAX_POS)) { // In theory, we don't need this check.
|
|
|
|
SERIAL_ERROR_START;
|
|
|
|
SERIAL_ERRORLNPGM("Attempt to edit off the bed."); // This really can't happen, but do the check for now
|
|
|
|
ubl.has_control_of_lcd_panel = false;
|
|
|
|
goto FINE_TUNE_EXIT;
|
|
|
|
}
|
|
|
|
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE); // Move the nozzle to where we are going to edit
|
|
|
|
do_blocking_move_to_xy(LOGICAL_X_POSITION(rawx), LOGICAL_Y_POSITION(rawy));
|
|
|
|
|
|
|
|
float new_z = ubl.z_values[location.x_index][location.y_index];
|
|
|
|
|
|
|
|
round_off = (int32_t)(new_z * 1000.0); // we chop off the last digits just to be clean. We are rounding to the
|
|
|
|
new_z = float(round_off) / 1000.0;
|
|
|
|
|
|
|
|
KEEPALIVE_STATE(PAUSED_FOR_USER);
|
|
|
|
ubl.has_control_of_lcd_panel = true;
|
|
|
|
|
|
|
|
lcd_implementation_clear();
|
|
|
|
lcd_mesh_edit_setup(new_z);
|
|
|
|
|
|
|
|
do {
|
|
|
|
new_z = lcd_mesh_edit();
|
|
|
|
idle();
|
|
|
|
} while (!ubl_lcd_clicked());
|
|
|
|
|
|
|
|
lcd_return_to_status();
|
|
|
|
|
|
|
|
ubl.has_control_of_lcd_panel = true; // There is a race condition for the Encoder Wheel getting clicked.
|
|
|
|
// It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune)
|
|
|
|
// or here.
|
|
|
|
|
|
|
|
const millis_t nxt = millis() + 1500UL;
|
|
|
|
while (ubl_lcd_clicked()) { // debounce and watch for abort
|
|
|
|
idle();
|
|
|
|
if (ELAPSED(millis(), nxt)) {
|
|
|
|
lcd_return_to_status();
|
|
|
|
//SERIAL_PROTOCOLLNPGM("\nFine Tuning of Mesh Stopped.");
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
|
|
|
lcd_setstatus("Mesh Editing Stopped", true);
|
|
|
|
|
|
|
|
while (ubl_lcd_clicked()) idle();
|
|
|
|
|
|
|
|
goto FINE_TUNE_EXIT;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
safe_delay(20); // We don't want any switch noise.
|
|
|
|
|
|
|
|
ubl.z_values[location.x_index][location.y_index] = new_z;
|
|
|
|
|
|
|
|
lcd_implementation_clear();
|
|
|
|
|
|
|
|
} while (location.x_index >= 0 && location.y_index >= 0 && --repetition_cnt);
|
|
|
|
|
|
|
|
FINE_TUNE_EXIT:
|
|
|
|
|
|
|
|
ubl.has_control_of_lcd_panel = false;
|
|
|
|
KEEPALIVE_STATE(IN_HANDLER);
|
|
|
|
|
|
|
|
if (do_ubl_mesh_map) ubl.display_map(map_type);
|
|
|
|
restore_ubl_active_state_and_leave();
|
|
|
|
do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE);
|
|
|
|
|
|
|
|
do_blocking_move_to_xy(lx, ly);
|
|
|
|
|
|
|
|
#if ENABLED(ULTRA_LCD)
|
|
|
|
lcd_setstatus("Done Editing Mesh", true);
|
|
|
|
#endif
|
|
|
|
SERIAL_ECHOLNPGM("Done Editing Mesh.");
|
|
|
|
}
|
|
|
|
|
|
|
|
#endif // AUTO_BED_LEVELING_UBL
|