* SanityCheck . h
*
* Test configuration values for errors at compile - time .
*/
# ifndef SANITYCHECK_H
# define SANITYCHECK_H
/**
* Dual Stepper Drivers
*/
# if defined(Z_DUAL_STEPPER_DRIVERS) && defined(Y_DUAL_STEPPER_DRIVERS)
# error You cannot have dual stepper drivers for both Y and Z.
# endif
/**
* Progress Bar
*/
# ifdef LCD_PROGRESS_BAR
# ifndef SDSUPPORT
# error LCD_PROGRESS_BAR requires SDSUPPORT.
# endif
# ifdef DOGLCD
# error LCD_PROGRESS_BAR does not apply to graphical displays.
# endif
# ifdef FILAMENT_LCD_DISPLAY
# error LCD_PROGRESS_BAR and FILAMENT_LCD_DISPLAY are not fully compatible. Comment out this line to use both.
# endif
# endif
/**
* Babystepping
*/
# ifdef BABYSTEPPING
# ifdef COREXY
# error BABYSTEPPING not implemented for COREXY yet.
# endif
# ifdef SCARA
# error BABYSTEPPING is not implemented for SCARA yet.
# endif
# if defined(DELTA) && defined(BABYSTEP_XY)
# error BABYSTEPPING only implemented for Z axis on deltabots.
# endif
# endif
/**
* Filament Change with Extruder Runout Prevention
*/
# if defined(FILAMENTCHANGEENABLE) && defined(EXTRUDER_RUNOUT_PREVENT)
# error EXTRUDER_RUNOUT_PREVENT currently incompatible with FILAMENTCHANGE.
# endif
/**
* Options only for EXTRUDERS = = 1
*/
# if EXTRUDERS > 1
# if EXTRUDERS > 4
# error The maximum number of EXTRUDERS in Marlin is 4.
# endif
# ifdef TEMP_SENSOR_1_AS_REDUNDANT
# error EXTRUDERS must be 1 with TEMP_SENSOR_1_AS_REDUNDANT.
# endif
# ifdef HEATERS_PARALLEL
# error EXTRUDERS must be 1 with HEATERS_PARALLEL.
# endif
# ifdef Y_DUAL_STEPPER_DRIVERS
# error EXTRUDERS must be 1 with Y_DUAL_STEPPER_DRIVERS.
# endif
# ifdef Z_DUAL_STEPPER_DRIVERS
# error EXTRUDERS must be 1 with Z_DUAL_STEPPER_DRIVERS.
# endif
# endif // EXTRUDERS > 1
/**
* Limited number of servos
*/
# if NUM_SERVOS > 4
# error The maximum number of SERVOS in Marlin is 4.
# endif
/**
* Servo deactivation depends on servo endstops
*/
# if defined(DEACTIVATE_SERVOS_AFTER_MOVE) && !defined(SERVO_ENDSTOPS)
# error SERVO_ENDSTOPS is required for DEACTIVATE_SERVOS_AFTER_MOVE.
# endif
/**
* Required LCD language
*/
# if !defined(DOGLCD) && defined(ULTRA_LCD) && !defined(DISPLAY_CHARSET_HD44780_JAPAN) && !defined(DISPLAY_CHARSET_HD44780_WESTERN)&& !defined(DISPLAY_CHARSET_HD44780_CYRILLIC)
# error You must enable either DISPLAY_CHARSET_HD44780_JAPAN or DISPLAY_CHARSET_HD44780_WESTERN or DISPLAY_CHARSET_HD44780_CYRILLIC for your LCD controller.
# endif
/**
* Mesh Bed Leveling
*/
# ifdef MESH_BED_LEVELING
# ifdef DELTA
# error MESH_BED_LEVELING does not yet support DELTA printers.
# endif
# ifdef ENABLE_AUTO_BED_LEVELING
# error Select ENABLE_AUTO_BED_LEVELING or MESH_BED_LEVELING, not both.
# endif
# if MESH_NUM_X_POINTS > 7 || MESH_NUM_Y_POINTS > 7
# error MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS need to be less than 8.
# endif
# endif
/**
* Auto Bed Leveling
*/
# ifdef ENABLE_AUTO_BED_LEVELING
/**
* Require a Z Min pin
*/
# if Z_MIN_PIN == -1
# if Z_PROBE_PIN == -1 || (!defined(Z_PROBE_ENDSTOP) || defined(DISABLE_Z_PROBE_ENDSTOP)) // It's possible for someone to set a pin for the Z Probe, but not enable it.
# ifdef Z_PROBE_REPEATABILITY_TEST
# error You must have a Z_MIN or Z_PROBE endstop to enable Z_PROBE_REPEATABILITY_TEST.
# else
# error ENABLE_AUTO_BED_LEVELING requires a Z_MIN or Z_PROBE endstop. Z_MIN_PIN or Z_PROBE_PIN must point to a valid hardware pin.
# endif
# endif
# endif
/**
* Require a Z Probe Pin if Z_PROBE_ENDSTOP is enabled .
*/
# if defined(Z_PROBE_ENDSTOP)
# ifndef Z_PROBE_PIN
# error You must have a Z_PROBE_PIN defined in your pins_XXXX.h file if you enable Z_PROBE_ENDSTOP.
# endif
# if Z_PROBE_PIN == -1
# error You must set Z_PROBE_PIN to a valid pin if you enable Z_PROBE_ENDSTOP.
# endif
// Forcing Servo definitions can break some hall effect sensor setups. Leaving these here for further comment.
// #ifndef NUM_SERVOS
// #error You must have NUM_SERVOS defined and there must be at least 1 configured to use Z_PROBE_ENDSTOP.
// #endif
// #if defined(NUM_SERVOS) && NUM_SERVOS < 1
// #error You must have at least 1 servo defined for NUM_SERVOS to use Z_PROBE_ENDSTOP.
// #endif
// #ifndef SERVO_ENDSTOPS
// #error You must have SERVO_ENDSTOPS defined and have the Z index set to at least 0 or above to use Z_PROBE_ENDSTOP.
// #endif
// #ifndef SERVO_ENDSTOP_ANGLES
// #error You must have SERVO_ENDSTOP_ANGLES defined for Z Extend and Retract to use Z_PROBE_ENDSTOP.
// #endif
# endif
/**
* Check if Probe_Offset * Grid Points is greater than Probing Range
*/
# ifdef AUTO_BED_LEVELING_GRID
# ifndef DELTA_PROBABLE_RADIUS
// Be sure points are in the right order
# if LEFT_PROBE_BED_POSITION > RIGHT_PROBE_BED_POSITION
# error LEFT_PROBE_BED_POSITION must be less than RIGHT_PROBE_BED_POSITION.
# elif FRONT_PROBE_BED_POSITION > BACK_PROBE_BED_POSITION
# error BACK_PROBE_BED_POSITION must be less than FRONT_PROBE_BED_POSITION.
# endif
// Make sure probing points are reachable
# if LEFT_PROBE_BED_POSITION < MIN_PROBE_X
# error "The given LEFT_PROBE_BED_POSITION can't be reached by the probe."
# elif RIGHT_PROBE_BED_POSITION > MAX_PROBE_X
# error "The given RIGHT_PROBE_BED_POSITION can't be reached by the probe."
# elif FRONT_PROBE_BED_POSITION < MIN_PROBE_Y
# error "The given FRONT_PROBE_BED_POSITION can't be reached by the probe."
# elif BACK_PROBE_BED_POSITION > MAX_PROBE_Y
# error "The given BACK_PROBE_BED_POSITION can't be reached by the probe."
# endif
# endif
# else // !AUTO_BED_LEVELING_GRID
// Check the triangulation points
# if ABL_PROBE_PT_1_X < MIN_PROBE_X || ABL_PROBE_PT_1_X > MAX_PROBE_X
# error "The given ABL_PROBE_PT_1_X can't be reached by the probe."
# elif ABL_PROBE_PT_2_X < MIN_PROBE_X || ABL_PROBE_PT_2_X > MAX_PROBE_X
# error "The given ABL_PROBE_PT_2_X can't be reached by the probe."
# elif ABL_PROBE_PT_3_X < MIN_PROBE_X || ABL_PROBE_PT_3_X > MAX_PROBE_X
# error "The given ABL_PROBE_PT_3_X can't be reached by the probe."
# elif ABL_PROBE_PT_1_Y < MIN_PROBE_Y || ABL_PROBE_PT_1_Y > MAX_PROBE_Y
# error "The given ABL_PROBE_PT_1_Y can't be reached by the probe."
# elif ABL_PROBE_PT_2_Y < MIN_PROBE_Y || ABL_PROBE_PT_2_Y > MAX_PROBE_Y
# error "The given ABL_PROBE_PT_2_Y can't be reached by the probe."
# elif ABL_PROBE_PT_3_Y < MIN_PROBE_Y || ABL_PROBE_PT_3_Y > MAX_PROBE_Y
# error "The given ABL_PROBE_PT_3_Y can't be reached by the probe."
# endif
# endif // !AUTO_BED_LEVELING_GRID
# endif // ENABLE_AUTO_BED_LEVELING
/**
* ULTIPANEL encoder
*/
# if defined(ULTIPANEL) && !defined(NEWPANEL) && !defined(SR_LCD_2W_NL) && !defined(SHIFT_CLK)
# error ULTIPANEL requires some kind of encoder.
# endif
/**
* Delta has limited bed leveling options
*/
# ifdef DELTA
# ifdef ENABLE_AUTO_BED_LEVELING
# ifndef AUTO_BED_LEVELING_GRID
# error Only AUTO_BED_LEVELING_GRID is supported with DELTA.
# endif
# ifdef Z_PROBE_SLED
# error You cannot use Z_PROBE_SLED with DELTA.
# endif
# ifdef Z_PROBE_REPEATABILITY_TEST
# error Z_PROBE_REPEATABILITY_TEST is not supported with DELTA yet.
# endif
# endif
# endif
/**
* Allen Key Z Probe requires Auto Bed Leveling grid and Delta
*/
# if defined(Z_PROBE_ALLEN_KEY) && !(defined(AUTO_BED_LEVELING_GRID) && defined(DELTA))
# error Invalid use of Z_PROBE_ALLEN_KEY.
# endif
/**
* Dual X Carriage requirements
*/
# ifdef DUAL_X_CARRIAGE
# if EXTRUDERS == 1 || defined(COREXY) \
| | ! HAS_X2_ENABLE | | ! HAS_X2_STEP | | ! HAS_X2_DIR \
| | ! defined ( X2_HOME_POS ) | | ! defined ( X2_MIN_POS ) | | ! defined ( X2_MAX_POS ) \
| | ! HAS_X_MAX
# error Missing or invalid definitions for DUAL_X_CARRIAGE mode.
# endif
# if X_HOME_DIR != -1 || X2_HOME_DIR != 1
# error Please use canonical x-carriage assignment.
# endif
# endif // DUAL_X_CARRIAGE
/**
* Make sure auto fan pins don ' t conflict with the fan pin
*/
# if HAS_AUTO_FAN && HAS_FAN
# if EXTRUDER_0_AUTO_FAN_PIN == FAN_PIN
# error You cannot set EXTRUDER_0_AUTO_FAN_PIN equal to FAN_PIN.
# elif EXTRUDER_1_AUTO_FAN_PIN == FAN_PIN
# error You cannot set EXTRUDER_1_AUTO_FAN_PIN equal to FAN_PIN.
# elif EXTRUDER_2_AUTO_FAN_PIN == FAN_PIN
# error You cannot set EXTRUDER_2_AUTO_FAN_PIN equal to FAN_PIN.
# elif EXTRUDER_3_AUTO_FAN_PIN == FAN_PIN
# error You cannot set EXTRUDER_3_AUTO_FAN_PIN equal to FAN_PIN.
# endif
# endif
# if HAS_FAN && CONTROLLERFAN_PIN == FAN_PIN
# error You cannot set CONTROLLERFAN_PIN equal to FAN_PIN.
# endif
/**
* Test required HEATER defines
*/
# if EXTRUDERS > 3
# if !HAS_HEATER_3
# error HEATER_3_PIN not defined for this board.
# endif
# elif EXTRUDERS > 2
# if !HAS_HEATER_2
# error HEATER_2_PIN not defined for this board.
# endif
# elif EXTRUDERS > 1 || defined(HEATERS_PARALLEL)
# if !HAS_HEATER_1
# error HEATER_1_PIN not defined for this board.
# endif
# endif
# if !HAS_HEATER_0
# error HEATER_0_PIN not defined for this board.
# endif
/**
* Warnings for old configurations
*/
# ifdef X_HOME_RETRACT_MM
# error [XYZ]_HOME_RETRACT_MM settings have been renamed [XYZ]_HOME_BUMP_MM.
# endif
# if WATCH_TEMP_PERIOD > 500
# error WATCH_TEMP_PERIOD now uses seconds instead of milliseconds.
# endif
# if !defined(THERMAL_PROTECTION_HOTENDS) && (defined(WATCH_TEMP_PERIOD) || defined(THERMAL_PROTECTION_PERIOD))
# error Thermal Runaway Protection for hotends must now be enabled with THERMAL_PROTECTION_HOTENDS.
# endif
# if !defined(THERMAL_PROTECTION_BED) && defined(THERMAL_PROTECTION_BED_PERIOD)
# error Thermal Runaway Protection for the bed must now be enabled with THERMAL_PROTECTION_BED.
# endif
# ifdef PROBE_SERVO_DEACTIVATION_DELAY
# error PROBE_SERVO_DEACTIVATION_DELAY has been replaced with DEACTIVATE_SERVOS_AFTER_MOVE and SERVO_DEACTIVATION_DELAY.
# endif
# if defined(COREXZ) && defined(Z_LATE_ENABLE)
# error "Z_LATE_ENABLE can't be used with COREXZ."
# endif
# endif //SANITYCHECK_H