Adjust comments, spacing

master
Scott Lahteine 8 years ago
parent b9d19b0008
commit 2c2688d7ad

@ -1372,8 +1372,8 @@ static void set_axis_is_at_home(AxisEnum axis) {
// SERIAL_ECHOLNPAIR(" Y:", homeposition[Y_AXIS]);
/**
* Works out real Homeposition angles using inverse kinematics,
* and calculates homing offset using forward kinematics
* Get Home position SCARA arm angles using inverse kinematics,
* and calculate homing offset using forward kinematics
*/
inverse_kinematics(homeposition);
forward_kinematics_SCARA(delta[A_AXIS], delta[B_AXIS]);
@ -2030,7 +2030,10 @@ static void clean_up_after_endstop_or_probe_move() {
SERIAL_ECHOLNPGM(")");
}
#endif
feedrate_mm_s = XY_PROBE_FEEDRATE_MM_S;
// Move the probe to the given XY
do_blocking_move_to_xy(x - (X_PROBE_OFFSET_FROM_EXTRUDER), y - (Y_PROBE_OFFSET_FROM_EXTRUDER));
if (DEPLOY_PROBE()) return NAN;
@ -2167,7 +2170,7 @@ static void clean_up_after_endstop_or_probe_move() {
#endif // AUTO_BED_LEVELING_NONLINEAR
/**
* Home an individual axis
* Home an individual linear axis
*/
static void do_homing_move(AxisEnum axis, float where, float fr_mm_s = 0.0) {
@ -3328,8 +3331,8 @@ inline void gcode_G28() {
return;
}
bool dryrun = code_seen('D');
bool stow_probe_after_each = code_seen('E');
bool dryrun = code_seen('D'),
stow_probe_after_each = code_seen('E');
#if ENABLED(AUTO_BED_LEVELING_GRID)
@ -3418,7 +3421,6 @@ inline void gcode_G28() {
#endif // !DELTA
// Inform the planner about the new coordinates
// (This is probably not needed here)
SYNC_PLAN_POSITION_KINEMATIC();
}
@ -3790,11 +3792,11 @@ inline void gcode_G28() {
* G92: Set current position to given X Y Z E
*/
inline void gcode_G92() {
bool didE = code_seen('E');
bool didXYZ = false,
didE = code_seen('E');
if (!didE) stepper.synchronize();
bool didXYZ = false;
LOOP_XYZE(i) {
if (code_seen(axis_codes[i])) {
float p = current_position[i],
@ -4179,7 +4181,7 @@ inline void gcode_M42() {
if (verbose_level > 2)
SERIAL_PROTOCOLLNPGM("Positioning the probe...");
// we don't do bed level correction in M48 because we want the raw data when we probe
// Disable bed level correction in M48 because we want the raw data when we probe
#if ENABLED(AUTO_BED_LEVELING_FEATURE)
reset_bed_level();
#endif
@ -5776,9 +5778,8 @@ inline void gcode_M303() {
}
#if ENABLED(MORGAN_SCARA)
bool SCARA_move_to_cal(uint8_t delta_a, uint8_t delta_b) {
//SoftEndsEnabled = false; // Ignore soft endstops during calibration
//SERIAL_ECHOLNPGM(" Soft endstops disabled");
if (IsRunning()) {
//gcode_get_destination(); // For X Y Z E F
forward_kinematics_SCARA(delta_a, delta_b);
@ -5786,7 +5787,6 @@ inline void gcode_M303() {
destination[Y_AXIS] = cartes[Y_AXIS];
destination[Z_AXIS] = current_position[Z_AXIS];
prepare_move_to_destination();
//ok_to_send();
return true;
}
return false;
@ -7977,7 +7977,7 @@ void set_current_from_steppers_for_axis(const AxisEnum axis) {
mesh_line_to_destination(fr_mm_s, x_splits, y_splits);
}
#endif // MESH_BED_LEVELING
#endif // MESH_BED_LEVELING
#if IS_KINEMATIC

Loading…
Cancel
Save