Scott Lahteine
6fa8fd15e2
Add negative temperatures for Thermistor 1
...
Changes from #5485 by @AndKe
8 years ago
Scott Lahteine
182c8d7f8f
Dyze High Temp Thermistor Support
8 years ago
Scott Lahteine
e03414b2dd
Simpler/extensible thermistor test in thermistortables.h
8 years ago
esenapaj
385945ca31
Cosmetic changes and small fix for thermistortables.h
...
・Adjust spacing
・Standardize comments position
・Remove ',' at the tail of array
9 years ago
esenapaj
888443ca1e
Enclose all #error strings with apostrophes
9 years ago
Scott Lahteine
0da744b7b0
Further cleanup of comments, partial Doxygen-style
...
Following up on #3231
9 years ago
jbrazio
5e5d250832
Added gplv3 header to all Marlin files
9 years ago
esenapaj
f260e00a72
fix spelling
...
Thermister -> Thermistor
9 years ago
jbrazio
b82d91eca6
Added configuration example for the BQ Hephestos 2 3D printer.
...
Added support for BQ ZUM Mega 3D board and stock Hephestos 2 thermistor.
9 years ago
Richard Wackerbarth
4f314afaf0
Allow Thermistor #12 to be used on hotends also
...
//100k 0603 SMD Vishay NTCS0603E3104FXT (4.7k pullup) (calibrated for Makibox hot bed)
Caveat Emptor —-
I’m not sure that this really makes sense,
but why keep someone from using it?
9 years ago
Scott Lahteine
0c7f7ebcfb
Styling adjustments (PR#2668 & PR#2670)
...
Keep "astyled" reformatting
9 years ago
Fourmi
e6aed7bb4e
Update thermistortables for Hisens Thermistor (PR#2588)
9 years ago
Scott Lahteine
278aa15301
Add COUNT macro and apply
9 years ago
AnHardt
c6d2ebe452
Extend the idea of dummy temperature sensors.
...
Added a second sensor and made them configurable.
10 years ago
alexborro
a57869ba49
Dummy Thermistor Table for testing purposes
...
Am I the only one who always need to change the thermistortable.h to add
a dummy table??
Ok, it is done. Just set the thermistor to 999 and it will always read
25C. Great for Testing or Development purposes.
10 years ago
MagoKimbra
986e723eeb
Add 4th extruder
10 years ago
Fourmi
af3e4d7510
Update line 627 ,wrong number on thermistortables
...
Wrong number on line 627 > i change number "12" by the correct number "13"
Soory
10 years ago
Fourmi
a664763e6f
Update thermistortables.h
...
Add another thermistor table (13),it's a cartridge thermistor up to +300°C,use with Hotend "Simple ONE" & "All In ONE"
Thx
10 years ago
Fourmi
c35736a140
Update thermistortables.h
...
Add another thermistor table,use with hotend "Simple ONE" & "All in ONE"
10 years ago
cocktailyogi
512f2a3136
restore Branch from Backup
...
sorry for that
11 years ago
Greg Tan
6e6e4e2143
Added thermistor table for the 500C thermistor shipped with the Pico hot end.
11 years ago
Cameron Lai
da6b536182
Add 5DPrint D8 Driver Board info and temperature table for Makibox hot bed
11 years ago
Nutz95
ed6f4a71c5
fix wrong temptable index
11 years ago
Nutz95
3161740df9
This table is made for thermistor 3950 (can be found on ebay for cheap)
...
it's caracteristics are :
R25℃ ;100KΩ±1%
B Value(R25/50℃):3990K 1%
Dissipation Factor(mW/℃):1.1~1.6 In still Air
Thermal Time Constant(S):10~17 In Still Air
Operating temperature range: (-50~+260°C)
Dimension: 1.8mm Dia X4.1mm
Lead Length :30mm
This table was found on the following blogs:
http://cae2100.wordpress.com/2014/03/08/beta3950-thermistor-table-for-marlin/
and
http://microfabricator.com/articles/view/id/531ad7e59aad9d3131000000/beta-3950-thermistor-table-for-marlin
11 years ago
David Forrest
b0093a1513
thermistortables.h: Add comments that table 60 uses beta=3950.
11 years ago
Josef Pavlik
831fc2a952
Pt100 and Pt1000 temperature sensors handling
11 years ago
daid
df194f75e1
Added PT100 support for Ultiboard2
11 years ago
Nicolas Rossi
4623e78ce0
Added Honeywell thermistor 135-104LAF-J01
11 years ago
ErikZalm
9f2862ce48
Merge pull request #414 from whosawhatsis/Marlin_v1
...
regenerated thermistor table 7
12 years ago
Ryan Turner
7c47e7162d
Adding Maker's Tool Works heated bed thermistor
12 years ago
whosawhatsis
6a61a3c0b4
missing comma in last commit
12 years ago
whosawhatsis
f0aee4101a
regenerated thermistor table 7
...
Generated with createTemperatureLookup.py. The old table crapped out at
270C, which was a problem for polycarbonate.
12 years ago
Denis B
49b2ddc8c1
Cleaned up non-standard characters
12 years ago
Daniele Sdei
3cf59f6f9a
add RepRapPro Huxley thermistor tables
12 years ago
daid303
7577717b59
Fixed #336
12 years ago
daid303
52158dffcc
Big temperature code update. No longer converts back and forwards between temperature and raw sample value. Reducing complexity, removing code. Also named some variables better. While keeping the safety intact and functionality the same.
12 years ago
MaikStohn
2b7b1e52b1
allow marlin internal 0°C represenation
12 years ago
Erik vd Zalm
0e89022cc3
Correct temptable_55 name.
12 years ago
Bernhard Kubicek
6b14f95b3e
Merge pull request #170 from linagee/Marlin_v1
...
Marlin v1
13 years ago
Bernhard Kubicek
b7fc14bc65
repaired thermistortable_6 by graphcial fitting of the off-slope values. see issue 179. Erik, I know you asked for no changes, but this file probably is not related and hopefully allright.
13 years ago
linagee
2e8c5049c5
Update Marlin/thermistortables.h
13 years ago
linagee
2d0d8e5272
Small correction.
13 years ago
linagee
9e9db65c3f
Update Marlin/thermistortables.h
13 years ago
linagee
bd966ef389
Update Marlin/thermistortables.h
13 years ago
linagee
775da3f103
Added top ratings and extended to ADC=1 for table 3 and 5.
13 years ago
linagee
96a4baa0be
Update Marlin/thermistortables.h
13 years ago
linagee
2aa9f7b131
Update Marlin/thermistortables.h
13 years ago
linagee
dd9144994e
Tested May 19 - It works! Verified with separate thermocouple TM-902C also.
13 years ago
linagee
4c37d0d9f1
Extended range above 250C. (Operating range states up to 300C)
13 years ago
linagee
241f5a4c0e
Update Marlin/thermistortables.h
13 years ago