WPBack
3b3e8a02b5
Initial implementation of PID Autotune Menu Items
...
Adds the parameter U to M303. If U1 is included , it will use the
PID-values from the auto-tune.
9 years ago
Scott Lahteine
06332f20be
Merge pull request #3113 from jbrazio/bugfix/3061-stop-print-time-counter
...
Stop print timer with M105/M109
9 years ago
Scott Lahteine
4bbea5124d
Support for multiple PWM fans
9 years ago
Scott Lahteine
2ef49a9d53
Wrap DEFAULT_Ki, DEFAULT_Kd, PID_dT
...
Addition to #3140
9 years ago
Scott Lahteine
1c384930f3
Merge pull request #3140 from thinkyhead/rc_fix_macro_expansion
...
Wrap macros to prevent bad expansions
9 years ago
Scott Lahteine
30c3a21d1f
Merge pull request #3112 from thinkyhead/rc_support_MAX31855
9 years ago
Scott Lahteine
f9ded2a7c4
Wrap macros to prevent bad expansions
9 years ago
jbrazio
a645860431
All print timer related activity now uses print_job_start(), print_job_timer() or print_job_stop()
9 years ago
Scott Lahteine
81aab828e2
Fix a "Heating failed" error
...
Addressing #3085 . If the target_temperature is set directly it never invokes or disables the timer set in `start_watching_heater`, so after _stopping a print_ or turning off _all heaters_ you could get a “Heating failed” error.
9 years ago
Scott Lahteine
27f244ba2c
Support MAX31855 as Temperature Sensor -3
9 years ago
jbrazio
986b508ff7
Print timer now stops when it sees the last extruder temperature being shutdown
9 years ago
Scott Lahteine
ff13070b59
Use _BV macros, patch up others
9 years ago
Scott Lahteine
209f5f21e0
Use macros where possible
...
Apply `constrain`, `NOMORE`, `NOLESS` and `CRITICAL_SECTION` macros
wherever possible.
9 years ago
Scott Lahteine
3a3d358df9
Fix Printrboard with LCD (redo)
...
Based on #2860 - rebased for RCBugFix
9 years ago
Blue-Marlin
0631541166
Fix disable_all_heaters() for MAX6675
9 years ago
AnHardt
57da1b8497
Host parseble output for M109, M190 and M303
...
Make the output of M105 more similar to Repetier.
Make the text-print pert of M105 an extra function to make it reusable. `print_heaterstates()`
Use `print_heaterstates()` in M019, M190 and M303
9 years ago
Richard Wackerbarth
956418c674
Kc is also a multi-PID parameter
9 years ago
Scott Lahteine
dbd4c17096
Init Kp, Ki, Kd to 0
9 years ago
Scott Lahteine
b4af4441c5
Clean up watchdog impl.
9 years ago
Scott Lahteine
9bdab4f3a8
Clean up "else" and other spacing
9 years ago
Richard Wackerbarth
25d636c9e0
Compiler issues (PR#2696)
9 years ago
AnHardt
47401ec97b
MSG_EXTRUDER_SWITCHED_OFF was renamed to MSG_REDUNDANCY
...
in language.h, but was not renamed here. If TEMP_SENSOR_1 is enabled as redundant then
an error is thrown that MSG_EXTRUDER_SWITCHED_OFF is not defined.
Originaly by @12dstring
9 years ago
Scott Lahteine
0c7f7ebcfb
Styling adjustments (PR#2668 & PR#2670)
...
Keep "astyled" reformatting
9 years ago
Scott Lahteine
bc50db9cf6
Implement PID_ADD_EXTRUSION_RATE
9 years ago
Scott Lahteine
51e89a269c
Overridable Options - Part 9 (PR#2561)
...
Apply `ENABLED` / `DISABLED` macros to temperature-related files.
9 years ago
AnHardt
d17f7ebc8a
Multiply WATCH_TEMP_PERIOD by 1000UL (PR#2535)
...
instead of 1000. Else we get errors with times over 32 seconds.
9 years ago
Scott Lahteine
e4c01f1c7e
Simplify init with ARRAY_BY_EXTRUDERS1 macro (PR#2507)
9 years ago
Scott Lahteine
77e80ef367
Require extruders for thermal code
9 years ago
Scott Lahteine
3bde4f4855
Require temp sensor for bed thermal protection
9 years ago
ayberkozgur
7268d46508
Always calculate extruder temperature PID d term (PR#2432)
9 years ago
Scott Lahteine
a274769f4f
Clean up spacing and comments
...
Also clean up some trailing spaces in a few other sources
10 years ago
Scott Lahteine
1d94d098bf
Formatting tweaks as part of fixing issue 1497
10 years ago
Scott Lahteine
e602c28ad9
Set auto fan pins to OUTPUT during init
...
Fixes the problem of these pins being left in INPUT state, as described
in #1497
10 years ago
MagoKimbra
eb81982fcd
Fix error next command in autotune (PR#2274)
...
Now send only temperature for T or B, but not send OK.
Host interprets the line to show the right temperature, but not in
response to M105 then stop and send commands until it ends the autotune.
10 years ago
AnHardt
b1404a0743
fix thermal protection state machine target temp. V2
...
If the target temperature is changed then it would always stay in the reset state.
Thanks to @tonokip.
Replaces #2119
10 years ago
Jonathan Bastien-Filiatrault
e86f2342c0
Separate the maximum integral power for the bed from PID_INTEGRAL_DRIVE_MAX / PID_MAX.
...
My PID_INTEGRAL_DRIVE_MAX was at 96, which was insufficient for my bed
to reach its intended temperature. The head requires a low maximum power since
I run on 24 volts and it has a somewhat low thermal mass.
10 years ago
AnHardt
da246f5cb1
Activate BED_MINTEMP error.
...
And call _temp_error() directly for ERR_MAXTEMP_BED to avoid the only one time use of bed_max_temp_error().
Includes #2156 .
10 years ago
AnHardt
959da98d8e
Call kill() only once when triggered by a temperature error
...
to avoid stack overflow when called from interrupt.
Some clean up for calls of disable_all_heaters().
'disable_all_heaters()' is called in kill() and again when 'killed' is already set inside _temp_error().
10 years ago
Scott Lahteine
063881b5bd
Fix a couple of doubled semicolons
10 years ago
Scott Lahteine
00716d0ca0
Small start_watching_heater adjustment
10 years ago
AnHardt
4422365a53
Merge branch 'Development' of https://github.com/MarlinFirmware/Marlin into _temp_error
10 years ago
AnHardt
4113762062
Merge pull request #2130 from AnHardt/kill2
...
Add a string parameter to kill()
10 years ago
AnHardt
120d4c7a8c
Merge remote-tracking branch 'origin/kill2' into _temp_error
10 years ago
AnHardt
cb6e82dc60
Change from kill() to kill(const char *)
...
in temperature.cpp
10 years ago
AnHardt
9d13942278
Use new kill() with parameter.
10 years ago
AnHardt
2990c6c45f
Use new kill_() for _temp_error()
...
instead of stop(). We really want to require a reset and no chance to set a new temperature.
10 years ago
AnHardt
70163dafb9
Use _temp_error() for all errors thrown by different mechanisms
...
Now ending in an endless loop.
Tidy up the output format.
We now get:
ERRORTEXT ", system stopped! Heater_ID: " HEATERID
Where ERRORTEXT can be:
"Heating failed"
"Thermal Runaway"
"MAXTEMP triggered"
"MINTEMP triggered"
and soon
"Thermal Jump"
HEATERID can be
0, 1, 2 ,3 , "bed"
This messages are always followed by the common:
"Printer stopped due to errors. Fix the error and use M999 to restart. (Temperature is reset. Set it after restarting)"
10 years ago
AnHardt
97ca1b3f4d
Name magic value 20 to MAX_OVERSHOOT_PID_AUTOTUNE
...
to make it better findable.
10 years ago
Scott Lahteine
f65833931d
Formatting tweaks
10 years ago
Scott Lahteine
d693e0f378
Use WATCH_TEMP_INCREASE + TEMP_HYSTERESIS + 1 as difference limit
10 years ago