Shane Francis
4c8330c15c
Trim Adjustments for Delta Configurations
9 years ago
Scott Lahteine
962120d1d2
Fix spacing in some conditional blocks
9 years ago
Richard Wackerbarth
20b4772155
Create DEBUG_LEVELING_FEATURE
9 years ago
Scott Lahteine
194f98ff95
Debug messages for homing and leveling
9 years ago
Richard Wackerbarth
6292d9e815
Rename ENABLE_AUTO_BED_LEVELING
...
With the introduction of the #if ENABLED(…)
reads better than
9 years ago
Richard Marko
91fd66ffba
add Lulzbot TAZ4 example configuration (PR#104)
9 years ago
Wurstnase
7a275773ee
remove colon in utf_mapper.h (PR#106)
9 years ago
Chris Bruner
6b4b6fa315
update for newest version of U8glib_Arduino
9 years ago
Christian Lefrançois
9897a9147c
Update ABL comments (PR#95)
...
* Updates the auto bed leveling comments ONLY.
* Renames "Z probe" word usage in //comments and #errors properly.
9 years ago
Christian Lefrançois
a7822e3ff7
Some renaming of Z_PROBE to Z_MIN_PROBE (PR#91)
...
* Fix a couple of renames omission and macro expansion errors.
9 years ago
Richard Wackerbarth
ad90e851b3
Use a small unsigned integer type
9 years ago
Richard Wackerbarth
29b456ae07
Suppress some compiler warnings
9 years ago
Scott Lahteine
23d742bf06
Don't free the stack array plane_equation_coefficients (PR#83)
9 years ago
Scott Lahteine
e3b1e08777
Patch G30 to use raise_z_for_servo (PR#73)
9 years ago
Scott Lahteine
a1eb90d5c0
Save another 30 bytes in gcode_SET_Z_PROBE_OFFSET
9 years ago
Scott Lahteine
91122277f4
Reduce gcode_SET_Z_PROBE_OFFSET by 88 bytes
9 years ago
AnHardt
5707a2c3d5
indexindexIntoAB is only vald for !DELTA
9 years ago
AnHardt
d8860f9ad9
Alway end at the same point
...
Always end at [RIGHT_PROBE_BED_POSITION, BACK_PROBE_BED_POSITION]
Regardles the evennes of auto_bed_leveling_grid_points.
9 years ago
AnHardt
4ca8f4a9a7
Always zigzag
...
Use the shortest way between probing-points.
9 years ago
AnHardt
3d23424121
Add array indexIntoAB[xx][yy]
...
and use it.
9 years ago
AnHardt
e2d69f66b2
Make Z_PROBE a Z_MIN_PROBE (PR#65)
...
Currently we use the probe exclusively as a device to find the build platform(bed).
For the currently supported setups this means, we use it as a additional min-endstop.
A triggered when not deployed probe disturbs the homing process for max-endstops.
Rename ENDSTOPPULLUP_ZPROBE to ENDSTOPPULLUP_ZMIN_PROBE
Rename Z_PROBE_ENDSTOP_INVERTING to Z_MIN_PROBE_ENDSTOP_INVERTING
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Rename DISABLE_Z_PROBE_ENDSTOP to DISABLE_Z_MIN_PROBE_ENDSTOP
Rename Z_PROBE_REPEATABILITY_TEST to Z_MIN_PROBE_REPEATABILITY_TEST
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Adjust comments accordingly
Remove Z_MAX check for the probe in update_endstops().
Using an delta related idea of @clefranc from #61 ,
extended to the general change for all setups.
Tested with Prusa i3, max-z-endstop and permanently triggered z-probe.
Worked for @clefranc's delta.
9 years ago
AnHardt
6a6e863a47
Resolve #2581 by adding a missed ';' (PR#67)
9 years ago
RicardoGA
e09ff79635
Update pins_RAMPS_13.h (PR#64)
...
Now all ramps configuration can enable Filament sensor not only EEB
9 years ago
Fourmi
e6aed7bb4e
Update thermistortables for Hisens Thermistor (PR#2588)
9 years ago
Richard Wackerbarth
9d8cc24abf
Continue from the line following the M999 (PR#60)
...
If the printer is going to accept the M999,
then it should continue from that line number.
9 years ago
wurstnase
f3ab1dba54
Z babystepping for coreXY (PR#47)
...
only X and Y were not implemented
9 years ago
Richard Wackerbarth
35afea1c0e
Restore test
...
PR#2572 Changed this because of faulty Boolean Logic
NOT(A OR (NOT B) OR (NOT C)) !=
(NOT A) AND ((NOT B) OR C))
Besides, the compiler should be smart enough to
optimize this without help from the programmer
9 years ago
Scott Lahteine
6af75f4b5d
Squish down deprecated tests in sanity check
9 years ago
Scott Lahteine
edeb58288e
Use PIN_EXISTS in sanity check
9 years ago
Scott Lahteine
c30b7693e0
Clean up RUMBA pins conditions
9 years ago
Scott Lahteine
46453905d6
Apply remaining ENABLED/DISABLED conditionals
9 years ago
Richard Wackerbarth
b227d8c128
Supply a VERSION in a short form for displays
...
The long descriptor will still be available in M115
9 years ago
Richard Wackerbarth
cd7828a928
This will be the 1.1.0 Release rather than 1.0.3
9 years ago
Richard Wackerbarth
4e2f5618c1
Pick up Default_version when needed
9 years ago
Richard Wackerbarth
329acc852e
Canonize Option flag USE_AUTOMATIC_VERSION
9 years ago
Richard Wackerbarth
5a11d32a85
Move deprecation test to SanityCheck.h
9 years ago
Richard Wackerbarth
7bb7a52940
Bring config up-to-date
9 years ago
AnHardt
244ea2014a
Boot-screen for text-displays improvements
...
Centred the logo for 16x4 and 20 x4.
Moved version to the bottom line
Code shrink to 704 bytes.
9 years ago
AnHardt
80f2a20842
Enable bootscreen in all Configurations
9 years ago
AnHardt
2684d061ed
Scroll too long strings on bootscreen
9 years ago
AnHardt
4f46df5dab
Make bootscreen configurable for the graphic displays
...
Saves about 473 byte of progmem and 28 bytes of RAM.
9 years ago
AnHardt
09571b7753
Boot-screen for the character displays
...
Uses about 488 byte of progmem and 32 byte of RAM.
For that configurable.
9 years ago
Richard Wackerbarth
866efc14fe
Add Danish translations
9 years ago
Scott Lahteine
267f3479d7
Adjust spacing in pins_RAMPS_13.h
9 years ago
Scott Lahteine
56702e7bb9
Define servo pins just like other pins
9 years ago
Richard Wackerbarth
4b9d5cd352
Use lowercase names for serial instances
9 years ago
Scott Lahteine
1e2deff4fd
Rename BTENABLED to BLUETOOTH
...
- For some reason it’s easy to forget what BT stands for, but it
doesn’t need an abbreviation.
9 years ago
Scott Lahteine
68055a5959
Include RIGIDBOT_PANEL in Conditionals
9 years ago
George Djabarov
f8ed3a835d
Added comment with the RigidBot Big bed size
9 years ago
George Djabarov
7deae6b6be
Updated RigidBot example configuration
...
- The default serial baud rate of 115200
- The regular RigitBot bed size 254mm/248mm/254mm
- Single stock extruder
- Stock termistors for extruder and hotbed
- Stock Min X/Y/Z stops. Max stops not connected
- Stock 32 teth tooleys (stock axis steps)
- No auto bed leveling
- No screen
9 years ago