/** * Marlin 3D Printer Firmware * Copyright (C) 2016 MarlinFirmware [https://github.com/MarlinFirmware/Marlin] * * Based on Sprinter and grbl. * Copyright (C) 2011 Camiel Gubbels / Erik van der Zalm * * This program is free software: you can redistribute it and/or modify * it under the terms of the GNU General Public License as published by * the Free Software Foundation, either version 3 of the License, or * (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * You should have received a copy of the GNU General Public License * along with this program. If not, see . * */ #include "MarlinConfig.h" #if ENABLED(AUTO_BED_LEVELING_UBL) #include "ubl.h" #include "Marlin.h" #include "hex_print_routines.h" #include "configuration_store.h" #include "ultralcd.h" #include "stepper.h" #include "gcode.h" #include #include "least_squares_fit.h" #define UBL_G29_P31 extern float destination[XYZE], current_position[XYZE]; void lcd_return_to_status(); bool lcd_clicked(); void lcd_implementation_clear(); void lcd_mesh_edit_setup(float initial); float lcd_mesh_edit(); void lcd_z_offset_edit_setup(float); float lcd_z_offset_edit(); extern float meshedit_done; extern long babysteps_done; extern float probe_pt(const float &x, const float &y, bool, int); extern bool set_probe_deployed(bool); #define SIZE_OF_LITTLE_RAISE 1 #define BIG_RAISE_NOT_NEEDED 0 extern void lcd_status_screen(); typedef void (*screenFunc_t)(); extern void lcd_goto_screen(screenFunc_t screen, const uint32_t encoder = 0); extern void lcd_setstatus(const char* message, const bool persist); extern void lcd_setstatuspgm(const char* message, const uint8_t level); int unified_bed_leveling::g29_verbose_level, unified_bed_leveling::g29_phase_value, unified_bed_leveling::g29_repetition_cnt, unified_bed_leveling::g29_storage_slot = 0, unified_bed_leveling::g29_map_type, unified_bed_leveling::g29_grid_size; bool unified_bed_leveling::g29_c_flag, unified_bed_leveling::g29_x_flag, unified_bed_leveling::g29_y_flag; float unified_bed_leveling::g29_x_pos, unified_bed_leveling::g29_y_pos, unified_bed_leveling::g29_card_thickness = 0.0, unified_bed_leveling::g29_constant = 0.0; /** * G29: Unified Bed Leveling by Roxy * * Parameters understood by this leveling system: * * A Activate Activate the Unified Bed Leveling system. * * B # Business Use the 'Business Card' mode of the Manual Probe subsystem. This is invoked as * G29 P2 B. The mode of G29 P2 allows you to use a business card or recipe card * as a shim that the nozzle will pinch as it is lowered. The idea is that you * can easily feel the nozzle getting to the same height by the amount of resistance * the business card exhibits to movement. You should try to achieve the same amount * of resistance on each probed point to facilitate accurate and repeatable measurements. * You should be very careful not to drive the nozzle into the business card with a * lot of force as it is very possible to cause damage to your printer if your are * careless. If you use the B option with G29 P2 B you can omit the numeric value * on first use to measure the business card's thickness. Subsequent usage of 'B' * will apply the previously-measured thickness as the default. * Note: A non-compressible Spark Gap feeler gauge is recommended over a Business Card. * * C Continue Continue, Constant, Current Location. This is not a primary command. C is used to * further refine the behaviour of several other commands. Issuing a G29 P1 C will * continue the generation of a partially constructed Mesh without invalidating what has * been done. Issuing a G29 P2 C will tell the Manual Probe subsystem to use the current * location in its search for the closest unmeasured Mesh Point. When used with a G29 Z C * it indicates to use the current location instead of defaulting to the center of the print bed. * * D Disable Disable the Unified Bed Leveling system. * * E Stow_probe Stow the probe after each sampled point. * * F # Fade Fade the amount of Mesh Based Compensation over a specified height. At the * specified height, no correction is applied and natural printer kenimatics take over. If no * number is specified for the command, 10mm is assumed to be reasonable. * * H # Height Specify the Height to raise the nozzle after each manual probe of the bed. The * default is 5mm. * * I # Invalidate Invalidate specified number of Mesh Points. The nozzle location is used unless * the X and Y parameter are used. If no number is specified, only the closest Mesh * point to the location is invalidated. The 'T' parameter is also available to produce * a map after the operation. This command is useful to invalidate a portion of the * Mesh so it can be adjusted using other tools in the Unified Bed Leveling System. When * attempting to invalidate an isolated bad point in the mesh, the 'T' option will indicate * where the nozzle is positioned in the Mesh with (#). You can move the nozzle around on * the bed and use this feature to select the center of the area (or cell) you want to * invalidate. * * J # Grid Perform a Grid Based Leveling of the current Mesh using a grid with n points on a side. * Not specifying a grid size will invoke the 3-Point leveling function. * * K # Kompare Kompare current Mesh with stored Mesh # replacing current Mesh with the result. This * command literally performs a diff between two Meshes. * * L Load Load Mesh from the previously activated location in the EEPROM. * * L # Load Load Mesh from the specified location in the EEPROM. Set this location as activated * for subsequent Load and Store operations. * * The P or Phase commands are used for the bulk of the work to setup a Mesh. In general, your Mesh will * start off being initialized with a G29 P0 or a G29 P1. Further refinement of the Mesh happens with * each additional Phase that processes it. * * P0 Phase 0 Zero Mesh Data and turn off the Mesh Compensation System. This reverts the * 3D Printer to the same state it was in before the Unified Bed Leveling Compensation * was turned on. Setting the entire Mesh to Zero is a special case that allows * a subsequent G or T leveling operation for backward compatibility. * * P1 Phase 1 Invalidate entire Mesh and continue with automatic generation of the Mesh data using * the Z-Probe. Usually the probe can't reach all areas that the nozzle can reach. On * Cartesian printers, points within the X_PROBE_OFFSET_FROM_EXTRUDER and Y_PROBE_OFFSET_FROM_EXTRUDER * area cannot be automatically probed. For Delta printers the area in which DELTA_PROBEABLE_RADIUS * and DELTA_PRINTABLE_RADIUS do not overlap will not be automatically probed. * * These points will be handled in Phase 2 and Phase 3. If the Phase 1 command is given the * C (Continue) parameter it does not invalidate the Mesh prior to automatically * probing needed locations. This allows you to invalidate portions of the Mesh but still * use the automatic probing capabilities of the Unified Bed Leveling System. An X and Y * parameter can be given to prioritize where the command should be trying to measure points. * If the X and Y parameters are not specified the current probe position is used. * P1 accepts a 'T' (Topology) parameter so you can observe mesh generation. * P1 also watches for the LCD Panel Encoder Switch to be held down, and will suspend * generation of the Mesh in that case. (Note: This check is only done between probe points, * so you must press and hold the switch until the Phase 1 command detects it.) * * P2 Phase 2 Probe areas of the Mesh that can't be automatically handled. Phase 2 respects an H * parameter to control the height between Mesh points. The default height for movement * between Mesh points is 5mm. A smaller number can be used to make this part of the * calibration less time consuming. You will be running the nozzle down until it just barely * touches the glass. You should have the nozzle clean with no plastic obstructing your view. * Use caution and move slowly. It is possible to damage your printer if you are careless. * Note that this command will use the configuration #define SIZE_OF_LITTLE_RAISE if the * nozzle is moving a distance of less than BIG_RAISE_NOT_NEEDED. * * The H parameter can be set negative if your Mesh dips in a large area. You can press * and hold the LCD Panel's encoder wheel to terminate the current Phase 2 command. You * can then re-issue the G29 P 2 command with an H parameter that is more suitable for the * area you are manually probing. Note that the command tries to start you in a corner * of the bed where movement will be predictable. You can force the location to be used in * the distance calculations by using the X and Y parameters. You may find it is helpful to * print out a Mesh Map (G29 T) to understand where the mesh is invalidated and where * the nozzle will need to move in order to complete the command. The C parameter is * available on the Phase 2 command also and indicates the search for points to measure should * be done based on the current location of the nozzle. * * A B parameter is also available for this command and described up above. It places the * manual probe subsystem into Business Card mode where the thickness of a business card is * measured and then used to accurately set the nozzle height in all manual probing for the * duration of the command. (S for Shim mode would be a better parameter name, but S is needed * for Save or Store of the Mesh to EEPROM) A Business card can be used, but you will have * better results if you use a flexible Shim that does not compress very much. That makes it * easier for you to get the nozzle to press with similar amounts of force against the shim so you * can get accurate measurements. As you are starting to touch the nozzle against the shim try * to get it to grasp the shim with the same force as when you measured the thickness of the * shim at the start of the command. * * Phase 2 allows the T (Map) parameter to be specified. This helps the user see the progression * of the Mesh being built. * * P3 Phase 3 Fill the unpopulated regions of the Mesh with a fixed value. There are two different paths the * user can go down. If the user specifies the value using the C parameter, the closest invalid * mesh points to the nozzle will be filled. The user can specify a repeat count using the R * parameter with the C version of the command. * * A second version of the fill command is available if no C constant is specified. Not * specifying a C constant will invoke the 'Smart Fill' algorithm. The G29 P3 command will search * from the edges of the mesh inward looking for invalid mesh points. It will look at the next * several mesh points to determine if the print bed is sloped up or down. If the bed is sloped * upward from the invalid mesh point, it will be replaced with the value of the nearest mesh point. * If the bed is sloped downward from the invalid mesh point, it will be replaced with a value that * puts all three points in a line. The second version of the G29 P3 command is a quick, easy and * usually safe way to populate the unprobed regions of your mesh so you can continue to the G26 * Mesh Validation Pattern phase. Please note that you are populating your mesh with unverified * numbers. You should use some scrutiny and caution. * * P4 Phase 4 Fine tune the Mesh. The Delta Mesh Compensation System assume the existence of * an LCD Panel. It is possible to fine tune the mesh without the use of an LCD Panel. * (More work and details on doing this later!) * The System will search for the closest Mesh Point to the nozzle. It will move the * nozzle to this location. The user can use the LCD Panel to carefully adjust the nozzle * so it is just barely touching the bed. When the user clicks the control, the System * will lock in that height for that point in the Mesh Compensation System. * * Phase 4 has several additional parameters that the user may find helpful. Phase 4 * can be started at a specific location by specifying an X and Y parameter. Phase 4 * can be requested to continue the adjustment of Mesh Points by using the R(epeat) * parameter. If the Repetition count is not specified, it is assumed the user wishes * to adjust the entire matrix. The nozzle is moved to the Mesh Point being edited. * The command can be terminated early (or after the area of interest has been edited) by * pressing and holding the encoder wheel until the system recognizes the exit request. * Phase 4's general form is G29 P4 [R # of points] [X position] [Y position] * * Phase 4 is intended to be used with the G26 Mesh Validation Command. Using the * information left on the printer's bed from the G26 command it is very straight forward * and easy to fine tune the Mesh. One concept that is important to remember and that * will make using the Phase 4 command easy to use is this: You are editing the Mesh Points. * If you have too little clearance and not much plastic was extruded in an area, you want to * LOWER the Mesh Point at the location. If you did not get good adheasion, you want to * RAISE the Mesh Point at that location. * * * P5 Phase 5 Find Mean Mesh Height and Standard Deviation. Typically, it is easier to use and * work with the Mesh if it is Mean Adjusted. You can specify a C parameter to * Correct the Mesh to a 0.00 Mean Height. Adding a C parameter will automatically * execute a G29 P6 C . * * P6 Phase 6 Shift Mesh height. The entire Mesh's height is adjusted by the height specified * with the C parameter. Being able to adjust the height of a Mesh is useful tool. It * can be used to compensate for poorly calibrated Z-Probes and other errors. Ideally, * you should have the Mesh adjusted for a Mean Height of 0.00 and the Z-Probe measuring * 0.000 at the Z Home location. * * Q Test Load specified Test Pattern to assist in checking correct operation of system. This * command is not anticipated to be of much value to the typical user. It is intended * for developers to help them verify correct operation of the Unified Bed Leveling System. * * R # Repeat Repeat this command the specified number of times. If no number is specified the * command will be repeated GRID_MAX_POINTS_X * GRID_MAX_POINTS_Y times. * * S Store Store the current Mesh in the Activated area of the EEPROM. It will also store the * current state of the Unified Bed Leveling system in the EEPROM. * * S # Store Store the current Mesh at the specified location in EEPROM. Activate this location * for subsequent Load and Store operations. Valid storage slot numbers begin at 0 and * extend to a limit related to the available EEPROM storage. * * S -1 Store Store the current Mesh as a print out that is suitable to be feed back into the system * at a later date. The GCode output can be saved and later replayed by the host software * to reconstruct the current mesh on another machine. * * T Topology Display the Mesh Map Topology. * 'T' can be used alone (e.g., G29 T) or in combination with most of the other commands. * This option works with all Phase commands (e.g., G29 P4 R 5 T X 50 Y100 C -.1 O) * This parameter can also specify a Map Type. T0 (the default) is user-readable. T1 can * is suitable to paste into a spreadsheet for a 3D graph of the mesh. * * U Unlevel Perform a probe of the outer perimeter to assist in physically leveling unlevel beds. * Only used for G29 P1 T U. This speeds up the probing of the edge of the bed. Useful * when the entire bed doesn't need to be probed because it will be adjusted. * * V # Verbosity Set the verbosity level (0-4) for extra details. (Default 0) * * W What? Display valuable Unified Bed Leveling System data. * * X # X Location for this command * * Y # Y Location for this command * * * Release Notes: * You MUST do M502, M500 to initialize the storage. Failure to do this will cause all * kinds of problems. Enabling EEPROM Storage is highly recommended. With EEPROM Storage * of the mesh, you are limited to 3-Point and Grid Leveling. (G29 P0 T and G29 P0 G * respectively.) * * When you do a G28 and then a G29 P1 to automatically build your first mesh, you are going to notice * the Unified Bed Leveling probes points further and further away from the starting location. (The * starting location defaults to the center of the bed.) The original Grid and Mesh leveling used * a Zig Zag pattern. The new pattern is better, especially for people with Delta printers. This * allows you to get the center area of the Mesh populated (and edited) quicker. This allows you to * perform a small print and check out your settings quicker. You do not need to populate the * entire mesh to use it. (You don't want to spend a lot of time generating a mesh only to realize * you don't have the resolution or zprobe_zoffset set correctly. The Mesh generation * gathers points closest to where the nozzle is located unless you specify an (X,Y) coordinate pair. * * The Unified Bed Leveling uses a lot of EEPROM storage to hold its data. And it takes some effort * to get this Mesh data correct for a user's printer. We do not want this data destroyed as * new versions of Marlin add or subtract to the items stored in EEPROM. So, for the benefit of * the users, we store the Mesh data at the end of the EEPROM and do not keep it contiguous with the * other data stored in the EEPROM. (For sure the developers are going to complain about this, but * this is going to be helpful to the users!) * * The foundation of this Bed Leveling System is built on Epatel's Mesh Bed Leveling code. A big * 'Thanks!' to him and the creators of 3-Point and Grid Based leveling. Combining their contributions * we now have the functionality and features of all three systems combined. */ void unified_bed_leveling::G29() { if (!settings.calc_num_meshes()) { SERIAL_PROTOCOLLNPGM("?You need to enable your EEPROM and initialize it"); SERIAL_PROTOCOLLNPGM("with M502, M500, M501 in that order.\n"); return; } // Check for commands that require the printer to be homed if (axis_unhomed_error()) { const int8_t p_val = parser.seen('P') && parser.has_value() ? parser.value_int() : -1; if (p_val == 1 || p_val == 2 || p_val == 4 || parser.seen('J')) home_all_axes(); } if (g29_parameter_parsing()) return; // abort if parsing the simple parameters causes a problem, // Invalidate Mesh Points. This command is a little bit asymmetrical because // it directly specifies the repetition count and does not use the 'R' parameter. if (parser.seen('I')) { uint8_t cnt = 0; g29_repetition_cnt = parser.has_value() ? parser.value_int() : 1; while (g29_repetition_cnt--) { if (cnt > 20) { cnt = 0; idle(); } const mesh_index_pair location = find_closest_mesh_point_of_type(REAL, g29_x_pos, g29_y_pos, USE_NOZZLE_AS_REFERENCE, NULL, false); if (location.x_index < 0) { SERIAL_PROTOCOLLNPGM("Entire Mesh invalidated.\n"); break; // No more invalid Mesh Points to populate } z_values[location.x_index][location.y_index] = NAN; cnt++; } SERIAL_PROTOCOLLNPGM("Locations invalidated.\n"); } if (parser.seen('Q')) { const int test_pattern = parser.has_value() ? parser.value_int() : -99; if (!WITHIN(test_pattern, -1, 2)) { SERIAL_PROTOCOLLNPGM("Invalid test_pattern value. (-1 to 2)\n"); return; } SERIAL_PROTOCOLLNPGM("Loading test_pattern values.\n"); switch (test_pattern) { case -1: g29_eeprom_dump(); break; case 0: for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) { // Create a bowl shape - similar to for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) { // a poorly calibrated Delta. const float p1 = 0.5 * (GRID_MAX_POINTS_X) - x, p2 = 0.5 * (GRID_MAX_POINTS_Y) - y; z_values[x][y] += 2.0 * HYPOT(p1, p2); } } break; case 1: for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) { // Create a diagonal line several Mesh cells thick that is raised z_values[x][x] += 9.999; z_values[x][x + (x < GRID_MAX_POINTS_Y - 1) ? 1 : -1] += 9.999; // We want the altered line several mesh points thick } break; case 2: // Allow the user to specify the height because 10mm is a little extreme in some cases. for (uint8_t x = (GRID_MAX_POINTS_X) / 3; x < 2 * (GRID_MAX_POINTS_X) / 3; x++) // Create a rectangular raised area in for (uint8_t y = (GRID_MAX_POINTS_Y) / 3; y < 2 * (GRID_MAX_POINTS_Y) / 3; y++) // the center of the bed z_values[x][y] += parser.seen('C') ? g29_constant : 9.99; break; } } if (parser.seen('J')) { if (g29_grid_size) { // if not 0 it is a normal n x n grid being probed save_ubl_active_state_and_disable(); tilt_mesh_based_on_probed_grid(parser.seen('T')); restore_ubl_active_state_and_leave(); } else { // grid_size == 0 : A 3-Point leveling has been requested float z3, z2, z1 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_1_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_1_Y), false, g29_verbose_level); if (!isnan(z1)) { z2 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_2_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_2_Y), false, g29_verbose_level); if (!isnan(z2)) z3 = probe_pt(LOGICAL_X_POSITION(UBL_PROBE_PT_3_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_3_Y), true, g29_verbose_level); } if (isnan(z1) || isnan(z2) || isnan(z3)) { // probe_pt will return NAN if unreachable SERIAL_ERROR_START; SERIAL_ERRORLNPGM("Attempt to probe off the bed."); goto LEAVE; } // Adjust z1, z2, z3 by the Mesh Height at these points. Just because they're non-zero // doesn't mean the Mesh is tilted! (Compensate each probe point by what the Mesh says // its height is.) save_ubl_active_state_and_disable(); z1 -= get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_1_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_1_Y)) /* + zprobe_zoffset */ ; z2 -= get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_2_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_2_Y)) /* + zprobe_zoffset */ ; z3 -= get_z_correction(LOGICAL_X_POSITION(UBL_PROBE_PT_3_X), LOGICAL_Y_POSITION(UBL_PROBE_PT_3_Y)) /* + zprobe_zoffset */ ; do_blocking_move_to_xy(0.5 * (UBL_MESH_MAX_X - (UBL_MESH_MIN_X)), 0.5 * (UBL_MESH_MAX_Y - (UBL_MESH_MIN_Y))); tilt_mesh_based_on_3pts(z1, z2, z3); restore_ubl_active_state_and_leave(); } } if (parser.seen('P')) { if (WITHIN(g29_phase_value, 0, 1) && state.storage_slot == -1) { state.storage_slot = 0; SERIAL_PROTOCOLLNPGM("Default storage slot 0 selected."); } switch (g29_phase_value) { case 0: // // Zero Mesh Data // reset(); SERIAL_PROTOCOLLNPGM("Mesh zeroed."); break; case 1: // // Invalidate Entire Mesh and Automatically Probe Mesh in areas that can be reached by the probe // if (!parser.seen('C')) { invalidate(); SERIAL_PROTOCOLLNPGM("Mesh invalidated. Probing mesh."); } if (g29_verbose_level > 1) { SERIAL_PROTOCOLPAIR("Probing Mesh Points Closest to (", g29_x_pos); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL(g29_y_pos); SERIAL_PROTOCOLLNPGM(").\n"); } probe_entire_mesh(g29_x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, g29_y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER, parser.seen('T'), parser.seen('E'), parser.seen('U')); break; case 2: { // // Manually Probe Mesh in areas that can't be reached by the probe // SERIAL_PROTOCOLLNPGM("Manually probing unreachable mesh locations."); do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES); if (!g29_x_flag && !g29_y_flag) { /** * Use a good default location for the path. * The flipped > and < operators in these comparisons is intentional. * It should cause the probed points to follow a nice path on Cartesian printers. * It may make sense to have Delta printers default to the center of the bed. * Until that is decided, this can be forced with the X and Y parameters. */ #if IS_KINEMATIC g29_x_pos = X_HOME_POS; g29_y_pos = Y_HOME_POS; #else // cartesian g29_x_pos = X_PROBE_OFFSET_FROM_EXTRUDER > 0 ? X_MAX_POS : X_MIN_POS; g29_y_pos = Y_PROBE_OFFSET_FROM_EXTRUDER < 0 ? Y_MAX_POS : Y_MIN_POS; #endif } if (parser.seen('C')) { g29_x_pos = current_position[X_AXIS]; g29_y_pos = current_position[Y_AXIS]; } float height = Z_CLEARANCE_BETWEEN_PROBES; if (parser.seen('B')) { g29_card_thickness = parser.has_value() ? parser.value_float() : measure_business_card_thickness(height); if (fabs(g29_card_thickness) > 1.5) { SERIAL_PROTOCOLLNPGM("?Error in Business Card measurement."); return; } } if (parser.seen('H') && parser.has_value()) height = parser.value_float(); if (!position_is_reachable_xy(g29_x_pos, g29_y_pos)) { SERIAL_PROTOCOLLNPGM("XY outside printable radius."); return; } manually_probe_remaining_mesh(g29_x_pos, g29_y_pos, height, g29_card_thickness, parser.seen('T')); SERIAL_PROTOCOLLNPGM("G29 P2 finished."); } break; case 3: { /** * Populate invalid mesh areas. Proceed with caution. * Two choices are available: * - Specify a constant with the 'C' parameter. * - Allow 'G29 P3' to choose a 'reasonable' constant. */ if (g29_c_flag) { if (g29_repetition_cnt >= GRID_MAX_POINTS) { for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) { for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) { z_values[x][y] = g29_constant; } } } else { while (g29_repetition_cnt--) { // this only populates reachable mesh points near const mesh_index_pair location = find_closest_mesh_point_of_type(INVALID, g29_x_pos, g29_y_pos, USE_NOZZLE_AS_REFERENCE, NULL, false); if (location.x_index < 0) break; // No more reachable invalid Mesh Points to populate z_values[location.x_index][location.y_index] = g29_constant; } } } else { const float cvf = parser.value_float(); switch((int)truncf(cvf * 10.0) - 30) { // 3.1 -> 1 #if ENABLED(UBL_G29_P31) case 1: { // P3.1 use least squares fit to fill missing mesh values // P3.10 zero weighting for distance, all grid points equal, best fit tilted plane // P3.11 10X weighting for nearest grid points versus farthest grid points // P3.12 100X distance weighting // P3.13 1000X distance weighting, approaches simple average of nearest points const float weight_power = (cvf - 3.10) * 100.0, // 3.12345 -> 2.345 weight_factor = weight_power ? pow(10.0, weight_power) : 0; smart_fill_wlsf(weight_factor); } break; #endif case 0: // P3 or P3.0 default: // and anything P3.x that's not P3.1 smart_fill_mesh(); // Do a 'Smart' fill using nearby known values break; } } break; } case 4: // // Fine Tune (i.e., Edit) the Mesh // fine_tune_mesh(g29_x_pos, g29_y_pos, parser.seen('T')); break; case 5: find_mean_mesh_height(); break; case 6: shift_mesh_height(); break; } } // // Much of the 'What?' command can be eliminated. But until we are fully debugged, it is // good to have the extra information. Soon... we prune this to just a few items // if (parser.seen('W')) g29_what_command(); // // When we are fully debugged, this may go away. But there are some valid // use cases for the users. So we can wait and see what to do with it. // if (parser.seen('K')) // Kompare Current Mesh Data to Specified Stored Mesh g29_compare_current_mesh_to_stored_mesh(); // // Load a Mesh from the EEPROM // if (parser.seen('L')) { // Load Current Mesh Data g29_storage_slot = parser.has_value() ? parser.value_int() : state.storage_slot; int16_t a = settings.calc_num_meshes(); if (!a) { SERIAL_PROTOCOLLNPGM("?EEPROM storage not available."); return; } if (!WITHIN(g29_storage_slot, 0, a - 1)) { SERIAL_PROTOCOLLNPGM("?Invalid storage slot."); SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1); return; } settings.load_mesh(g29_storage_slot); state.storage_slot = g29_storage_slot; SERIAL_PROTOCOLLNPGM("Done."); } // // Store a Mesh in the EEPROM // if (parser.seen('S')) { // Store (or Save) Current Mesh Data g29_storage_slot = parser.has_value() ? parser.value_int() : state.storage_slot; if (g29_storage_slot == -1) { // Special case, we are going to 'Export' the mesh to the SERIAL_ECHOLNPGM("G29 I 999"); // host in a form it can be reconstructed on a different machine for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) if (!isnan(z_values[x][y])) { SERIAL_ECHOPAIR("M421 I ", x); SERIAL_ECHOPAIR(" J ", y); SERIAL_ECHOPGM(" Z "); SERIAL_ECHO_F(z_values[x][y], 6); SERIAL_ECHOPAIR(" ; X ", LOGICAL_X_POSITION(mesh_index_to_xpos(x))); SERIAL_ECHOPAIR(", Y ", LOGICAL_Y_POSITION(mesh_index_to_ypos(y))); SERIAL_EOL; } return; } int16_t a = settings.calc_num_meshes(); if (!a) { SERIAL_PROTOCOLLNPGM("?EEPROM storage not available."); goto LEAVE; } if (!WITHIN(g29_storage_slot, 0, a - 1)) { SERIAL_PROTOCOLLNPGM("?Invalid storage slot."); SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1); goto LEAVE; } settings.store_mesh(g29_storage_slot); state.storage_slot = g29_storage_slot; SERIAL_PROTOCOLLNPGM("Done."); } if (parser.seen('T')) display_map(parser.has_value() ? parser.value_int() : 0); /** * This code may not be needed... Prepare for its removal... * */ #if 0 if (parser.seen('Z')) { if (parser.has_value()) state.z_offset = parser.value_float(); // do the simple case. Just lock in the specified value else { save_ubl_active_state_and_disable(); //float measured_z = probe_pt(g29_x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, g29_y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER, ProbeDeployAndStow, g29_verbose_level); has_control_of_lcd_panel = true; // Grab the LCD Hardware float measured_z = 1.5; do_blocking_move_to_z(measured_z); // Get close to the bed, but leave some space so we don't damage anything // The user is not going to be locking in a new Z-Offset very often so // it won't be that painful to spin the Encoder Wheel for 1.5mm lcd_implementation_clear(); lcd_z_offset_edit_setup(measured_z); KEEPALIVE_STATE(PAUSED_FOR_USER); do { measured_z = lcd_z_offset_edit(); idle(); do_blocking_move_to_z(measured_z); } while (!ubl_lcd_clicked()); has_control_of_lcd_panel = true; // There is a race condition for the encoder click. // It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune) // or here. So, until we are done looking for a long encoder press, // we need to take control of the panel KEEPALIVE_STATE(IN_HANDLER); lcd_return_to_status(); const millis_t nxt = millis() + 1500UL; while (ubl_lcd_clicked()) { // debounce and watch for abort idle(); if (ELAPSED(millis(), nxt)) { SERIAL_PROTOCOLLNPGM("\nZ-Offset Adjustment Stopped."); do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE); LCD_MESSAGEPGM("Z-Offset Stopped"); // TODO: Make translatable string restore_ubl_active_state_and_leave(); goto LEAVE; } } has_control_of_lcd_panel = false; safe_delay(20); // We don't want any switch noise. state.z_offset = measured_z; lcd_implementation_clear(); restore_ubl_active_state_and_leave(); } } #endif LEAVE: lcd_reset_alert_level(); LCD_MESSAGEPGM(""); lcd_quick_feedback(); has_control_of_lcd_panel = false; } void unified_bed_leveling::find_mean_mesh_height() { float sum = 0.0; int n = 0; for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) if (!isnan(z_values[x][y])) { sum += z_values[x][y]; n++; } const float mean = sum / n; // // Sum the squares of difference from mean // float sum_of_diff_squared = 0.0; for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) if (!isnan(z_values[x][y])) sum_of_diff_squared += sq(z_values[x][y] - mean); SERIAL_ECHOLNPAIR("# of samples: ", n); SERIAL_ECHOPGM("Mean Mesh Height: "); SERIAL_ECHO_F(mean, 6); SERIAL_EOL; const float sigma = sqrt(sum_of_diff_squared / (n + 1)); SERIAL_ECHOPGM("Standard Deviation: "); SERIAL_ECHO_F(sigma, 6); SERIAL_EOL; if (g29_c_flag) for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) if (!isnan(z_values[x][y])) z_values[x][y] -= mean + g29_constant; } void unified_bed_leveling::shift_mesh_height() { for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) if (!isnan(z_values[x][y])) z_values[x][y] += g29_constant; } /** * Probe all invalidated locations of the mesh that can be reached by the probe. * This attempts to fill in locations closest to the nozzle's start location first. */ void unified_bed_leveling::probe_entire_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map, const bool stow_probe, bool close_or_far) { mesh_index_pair location; has_control_of_lcd_panel = true; save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe DEPLOY_PROBE(); uint16_t max_iterations = GRID_MAX_POINTS; do { if (ubl_lcd_clicked()) { SERIAL_PROTOCOLLNPGM("\nMesh only partially populated.\n"); lcd_quick_feedback(); STOW_PROBE(); while (ubl_lcd_clicked()) idle(); has_control_of_lcd_panel = false; restore_ubl_active_state_and_leave(); safe_delay(50); // Debounce the Encoder wheel return; } location = find_closest_mesh_point_of_type(INVALID, lx, ly, USE_PROBE_AS_REFERENCE, NULL, close_or_far); if (location.x_index >= 0) { // mesh point found and is reachable by probe const float rawx = mesh_index_to_xpos(location.x_index), rawy = mesh_index_to_ypos(location.y_index); const float measured_z = probe_pt(LOGICAL_X_POSITION(rawx), LOGICAL_Y_POSITION(rawy), stow_probe, g29_verbose_level); // TODO: Needs error handling z_values[location.x_index][location.y_index] = measured_z; } if (do_ubl_mesh_map) display_map(g29_map_type); } while (location.x_index >= 0 && --max_iterations); STOW_PROBE(); restore_ubl_active_state_and_leave(); do_blocking_move_to_xy( constrain(lx - (X_PROBE_OFFSET_FROM_EXTRUDER), UBL_MESH_MIN_X, UBL_MESH_MAX_X), constrain(ly - (Y_PROBE_OFFSET_FROM_EXTRUDER), UBL_MESH_MIN_Y, UBL_MESH_MAX_Y) ); } void unified_bed_leveling::tilt_mesh_based_on_3pts(const float &z1, const float &z2, const float &z3) { matrix_3x3 rotation; vector_3 v1 = vector_3( (UBL_PROBE_PT_1_X - UBL_PROBE_PT_2_X), (UBL_PROBE_PT_1_Y - UBL_PROBE_PT_2_Y), (z1 - z2) ), v2 = vector_3( (UBL_PROBE_PT_3_X - UBL_PROBE_PT_2_X), (UBL_PROBE_PT_3_Y - UBL_PROBE_PT_2_Y), (z3 - z2) ), normal = vector_3::cross(v1, v2); normal = normal.get_normal(); /** * This vector is normal to the tilted plane. * However, we don't know its direction. We need it to point up. So if * Z is negative, we need to invert the sign of all components of the vector */ if (normal.z < 0.0) { normal.x = -normal.x; normal.y = -normal.y; normal.z = -normal.z; } rotation = matrix_3x3::create_look_at(vector_3(normal.x, normal.y, 1)); if (g29_verbose_level > 2) { SERIAL_ECHOPGM("bed plane normal = ["); SERIAL_PROTOCOL_F(normal.x, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(normal.y, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(normal.z, 7); SERIAL_ECHOLNPGM("]"); rotation.debug(PSTR("rotation matrix:")); } // // All of 3 of these points should give us the same d constant // float t = normal.x * (UBL_PROBE_PT_1_X) + normal.y * (UBL_PROBE_PT_1_Y), d = t + normal.z * z1; if (g29_verbose_level>2) { SERIAL_ECHOPGM("D constant: "); SERIAL_PROTOCOL_F(d, 7); SERIAL_ECHOLNPGM(" "); } #if ENABLED(DEBUG_LEVELING_FEATURE) if (DEBUGGING(LEVELING)) { SERIAL_ECHOPGM("d from 1st point: "); SERIAL_ECHO_F(d, 6); SERIAL_EOL; t = normal.x * (UBL_PROBE_PT_2_X) + normal.y * (UBL_PROBE_PT_2_Y); d = t + normal.z * z2; SERIAL_ECHOPGM("d from 2nd point: "); SERIAL_ECHO_F(d, 6); SERIAL_EOL; t = normal.x * (UBL_PROBE_PT_3_X) + normal.y * (UBL_PROBE_PT_3_Y); d = t + normal.z * z3; SERIAL_ECHOPGM("d from 3rd point: "); SERIAL_ECHO_F(d, 6); SERIAL_EOL; } #endif for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) { for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) { float x_tmp = mesh_index_to_xpos(i), y_tmp = mesh_index_to_ypos(j), z_tmp = z_values[i][j]; #if ENABLED(DEBUG_LEVELING_FEATURE) if (DEBUGGING(LEVELING)) { SERIAL_ECHOPGM("before rotation = ["); SERIAL_PROTOCOL_F(x_tmp, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(y_tmp, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(z_tmp, 7); SERIAL_ECHOPGM("] ---> "); safe_delay(20); } #endif apply_rotation_xyz(rotation, x_tmp, y_tmp, z_tmp); #if ENABLED(DEBUG_LEVELING_FEATURE) if (DEBUGGING(LEVELING)) { SERIAL_ECHOPGM("after rotation = ["); SERIAL_PROTOCOL_F(x_tmp, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(y_tmp, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(z_tmp, 7); SERIAL_ECHOLNPGM("]"); safe_delay(55); } #endif z_values[i][j] += z_tmp - d; } } } float unified_bed_leveling::measure_point_with_encoder() { while (ubl_lcd_clicked()) delay(50); // wait for user to release encoder wheel delay(50); // debounce KEEPALIVE_STATE(PAUSED_FOR_USER); while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here! idle(); if (encoder_diff) { do_blocking_move_to_z(current_position[Z_AXIS] + 0.01 * float(encoder_diff)); encoder_diff = 0; } } KEEPALIVE_STATE(IN_HANDLER); return current_position[Z_AXIS]; } static void echo_and_take_a_measurement() { SERIAL_PROTOCOLLNPGM(" and take a measurement."); } float unified_bed_leveling::measure_business_card_thickness(float &in_height) { has_control_of_lcd_panel = true; save_ubl_active_state_and_disable(); // Disable bed level correction for probing do_blocking_move_to_z(in_height); do_blocking_move_to_xy(0.5 * (UBL_MESH_MAX_X - (UBL_MESH_MIN_X)), 0.5 * (UBL_MESH_MAX_Y - (UBL_MESH_MIN_Y))); //, min(planner.max_feedrate_mm_s[X_AXIS], planner.max_feedrate_mm_s[Y_AXIS]) / 2.0); stepper.synchronize(); SERIAL_PROTOCOLPGM("Place shim under nozzle"); LCD_MESSAGEPGM("Place shim & measure"); // TODO: Make translatable string lcd_goto_screen(lcd_status_screen); echo_and_take_a_measurement(); const float z1 = measure_point_with_encoder(); do_blocking_move_to_z(current_position[Z_AXIS] + SIZE_OF_LITTLE_RAISE); stepper.synchronize(); SERIAL_PROTOCOLPGM("Remove shim"); LCD_MESSAGEPGM("Remove & measure bed"); // TODO: Make translatable string echo_and_take_a_measurement(); const float z2 = measure_point_with_encoder(); do_blocking_move_to_z(current_position[Z_AXIS] + Z_CLEARANCE_BETWEEN_PROBES); const float thickness = abs(z1 - z2); if (g29_verbose_level > 1) { SERIAL_PROTOCOLPGM("Business Card is "); SERIAL_PROTOCOL_F(thickness, 4); SERIAL_PROTOCOLLNPGM("mm thick."); } in_height = current_position[Z_AXIS]; // do manual probing at lower height has_control_of_lcd_panel = false; restore_ubl_active_state_and_leave(); return thickness; } void unified_bed_leveling::manually_probe_remaining_mesh(const float &lx, const float &ly, const float &z_clearance, const float &thick, const bool do_ubl_mesh_map) { has_control_of_lcd_panel = true; save_ubl_active_state_and_disable(); // we don't do bed level correction because we want the raw data when we probe do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES); do_blocking_move_to_xy(lx, ly); lcd_goto_screen(lcd_status_screen); mesh_index_pair location; do { location = find_closest_mesh_point_of_type(INVALID, lx, ly, USE_NOZZLE_AS_REFERENCE, NULL, false); // It doesn't matter if the probe can't reach the NAN location. This is a manual probe. if (location.x_index < 0 && location.y_index < 0) continue; const float rawx = mesh_index_to_xpos(location.x_index), rawy = mesh_index_to_ypos(location.y_index), xProbe = LOGICAL_X_POSITION(rawx), yProbe = LOGICAL_Y_POSITION(rawy); if (!position_is_reachable_raw_xy(rawx, rawy)) break; // SHOULD NOT OCCUR (find_closest_mesh_point only returns reachable points) do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES); LCD_MESSAGEPGM("Moving to next"); // TODO: Make translatable string do_blocking_move_to_xy(xProbe, yProbe); do_blocking_move_to_z(z_clearance); KEEPALIVE_STATE(PAUSED_FOR_USER); has_control_of_lcd_panel = true; if (do_ubl_mesh_map) display_map(g29_map_type); // show user where we're probing serialprintPGM(parser.seen('B') ? PSTR("Place shim & measure") : PSTR("Measure")); // TODO: Make translatable strings while (ubl_lcd_clicked()) delay(50); // wait for user to release encoder wheel delay(50); // debounce while (!ubl_lcd_clicked()) { // we need the loop to move the nozzle based on the encoder wheel here! idle(); if (encoder_diff) { do_blocking_move_to_z(current_position[Z_AXIS] + float(encoder_diff) / 100.0); encoder_diff = 0; } } // this sequence to detect an ubl_lcd_clicked() debounce it and leave if it is // a Press and Hold is repeated in a lot of places (including G26_Mesh_Validation.cpp). This // should be redone and compressed. const millis_t nxt = millis() + 1500L; while (ubl_lcd_clicked()) { // debounce and watch for abort idle(); if (ELAPSED(millis(), nxt)) { SERIAL_PROTOCOLLNPGM("\nMesh only partially populated."); do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE); lcd_quick_feedback(); while (ubl_lcd_clicked()) idle(); has_control_of_lcd_panel = false; KEEPALIVE_STATE(IN_HANDLER); restore_ubl_active_state_and_leave(); return; } } z_values[location.x_index][location.y_index] = current_position[Z_AXIS] - thick; if (g29_verbose_level > 2) { SERIAL_PROTOCOLPGM("Mesh Point Measured at: "); SERIAL_PROTOCOL_F(z_values[location.x_index][location.y_index], 6); SERIAL_EOL; } } while (location.x_index >= 0 && location.y_index >= 0); if (do_ubl_mesh_map) display_map(g29_map_type); restore_ubl_active_state_and_leave(); KEEPALIVE_STATE(IN_HANDLER); do_blocking_move_to_z(Z_CLEARANCE_DEPLOY_PROBE); do_blocking_move_to_xy(lx, ly); } bool unified_bed_leveling::g29_parameter_parsing() { bool err_flag = false; LCD_MESSAGEPGM("Doing G29 UBL!"); // TODO: Make translatable string lcd_quick_feedback(); g29_constant = 0.0; g29_repetition_cnt = 0; g29_x_flag = parser.seen('X') && parser.has_value(); g29_x_pos = g29_x_flag ? parser.value_float() : current_position[X_AXIS]; g29_y_flag = parser.seen('Y') && parser.has_value(); g29_y_pos = g29_y_flag ? parser.value_float() : current_position[Y_AXIS]; if (parser.seen('R')) { g29_repetition_cnt = parser.has_value() ? parser.value_int() : GRID_MAX_POINTS; NOMORE(g29_repetition_cnt, GRID_MAX_POINTS); if (g29_repetition_cnt < 1) { SERIAL_PROTOCOLLNPGM("?(R)epetition count invalid (1+).\n"); return UBL_ERR; } } g29_verbose_level = parser.seen('V') ? parser.value_int() : 0; if (!WITHIN(g29_verbose_level, 0, 4)) { SERIAL_PROTOCOLLNPGM("?(V)erbose level is implausible (0-4).\n"); err_flag = true; } if (parser.seen('P')) { g29_phase_value = parser.value_int(); if (!WITHIN(g29_phase_value, 0, 6)) { SERIAL_PROTOCOLLNPGM("?(P)hase value invalid (0-6).\n"); err_flag = true; } } if (parser.seen('J')) { g29_grid_size = parser.has_value() ? parser.value_int() : 0; if (g29_grid_size && !WITHIN(g29_grid_size, 2, 9)) { SERIAL_PROTOCOLLNPGM("?Invalid grid size (J) specified (2-9).\n"); err_flag = true; } } if (g29_x_flag != g29_y_flag) { SERIAL_PROTOCOLLNPGM("Both X & Y locations must be specified.\n"); err_flag = true; } if (!WITHIN(RAW_X_POSITION(g29_x_pos), X_MIN_POS, X_MAX_POS)) { SERIAL_PROTOCOLLNPGM("Invalid X location specified.\n"); err_flag = true; } if (!WITHIN(RAW_Y_POSITION(g29_y_pos), Y_MIN_POS, Y_MAX_POS)) { SERIAL_PROTOCOLLNPGM("Invalid Y location specified.\n"); err_flag = true; } if (err_flag) return UBL_ERR; /** * Activate or deactivate UBL * Note: UBL's G29 restores the state set here when done. * Leveling is being enabled here with old data, possibly * none. Error handling should disable for safety... */ if (parser.seen('A')) { if (parser.seen('D')) { SERIAL_PROTOCOLLNPGM("?Can't activate and deactivate at the same time.\n"); return UBL_ERR; } state.active = true; report_state(); } else if (parser.seen('D')) { state.active = false; report_state(); } // Set global 'C' flag and its value if ((g29_c_flag = parser.seen('C'))) g29_constant = parser.value_float(); #if ENABLED(ENABLE_LEVELING_FADE_HEIGHT) if (parser.seen('F') && parser.has_value()) { const float fh = parser.value_float(); if (!WITHIN(fh, 0.0, 100.0)) { SERIAL_PROTOCOLLNPGM("?(F)ade height for Bed Level Correction not plausible.\n"); return UBL_ERR; } set_z_fade_height(fh); } #endif g29_map_type = parser.seen('T') && parser.has_value() ? parser.value_int() : 0; if (!WITHIN(g29_map_type, 0, 1)) { SERIAL_PROTOCOLLNPGM("Invalid map type.\n"); return UBL_ERR; } return UBL_OK; } static int ubl_state_at_invocation = 0, ubl_state_recursion_chk = 0; void unified_bed_leveling::save_ubl_active_state_and_disable() { ubl_state_recursion_chk++; if (ubl_state_recursion_chk != 1) { SERIAL_ECHOLNPGM("save_ubl_active_state_and_disabled() called multiple times in a row."); LCD_MESSAGEPGM("save_UBL_active() error"); // TODO: Make translatable string lcd_quick_feedback(); return; } ubl_state_at_invocation = state.active; state.active = 0; } void unified_bed_leveling::restore_ubl_active_state_and_leave() { if (--ubl_state_recursion_chk) { SERIAL_ECHOLNPGM("restore_ubl_active_state_and_leave() called too many times."); LCD_MESSAGEPGM("restore_UBL_active() error"); // TODO: Make translatable string lcd_quick_feedback(); return; } state.active = ubl_state_at_invocation; } /** * Much of the 'What?' command can be eliminated. But until we are fully debugged, it is * good to have the extra information. Soon... we prune this to just a few items */ void unified_bed_leveling::g29_what_command() { report_state(); if (state.storage_slot == -1) SERIAL_PROTOCOLPGM("No Mesh Loaded."); else { SERIAL_PROTOCOLPAIR("Mesh ", state.storage_slot); SERIAL_PROTOCOLPGM(" Loaded."); } SERIAL_EOL; safe_delay(50); SERIAL_PROTOCOLLNPAIR("UBL object count: ", (int)ubl_cnt); #if ENABLED(ENABLE_LEVELING_FADE_HEIGHT) SERIAL_PROTOCOL("planner.z_fade_height : "); SERIAL_PROTOCOL_F(planner.z_fade_height, 4); SERIAL_EOL; #endif #if HAS_BED_PROBE SERIAL_PROTOCOLPGM("zprobe_zoffset: "); SERIAL_PROTOCOL_F(zprobe_zoffset, 7); SERIAL_EOL; #endif SERIAL_ECHOLNPAIR("UBL_MESH_MIN_X " STRINGIFY(UBL_MESH_MIN_X) "=", UBL_MESH_MIN_X); SERIAL_ECHOLNPAIR("UBL_MESH_MIN_Y " STRINGIFY(UBL_MESH_MIN_Y) "=", UBL_MESH_MIN_Y); safe_delay(25); SERIAL_ECHOLNPAIR("UBL_MESH_MAX_X " STRINGIFY(UBL_MESH_MAX_X) "=", UBL_MESH_MAX_X); SERIAL_ECHOLNPAIR("UBL_MESH_MAX_Y " STRINGIFY(UBL_MESH_MAX_Y) "=", UBL_MESH_MAX_Y); safe_delay(25); SERIAL_ECHOLNPAIR("GRID_MAX_POINTS_X ", GRID_MAX_POINTS_X); SERIAL_ECHOLNPAIR("GRID_MAX_POINTS_Y ", GRID_MAX_POINTS_Y); safe_delay(25); SERIAL_ECHOLNPAIR("MESH_X_DIST ", MESH_X_DIST); SERIAL_ECHOLNPAIR("MESH_Y_DIST ", MESH_Y_DIST); safe_delay(25); SERIAL_PROTOCOLPGM("X-Axis Mesh Points at: "); for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) { SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(mesh_index_to_xpos(i)), 3); SERIAL_PROTOCOLPGM(" "); safe_delay(25); } SERIAL_EOL; SERIAL_PROTOCOLPGM("Y-Axis Mesh Points at: "); for (uint8_t i = 0; i < GRID_MAX_POINTS_Y; i++) { SERIAL_PROTOCOL_F(LOGICAL_Y_POSITION(mesh_index_to_ypos(i)), 3); SERIAL_PROTOCOLPGM(" "); safe_delay(25); } SERIAL_EOL; #if HAS_KILL SERIAL_PROTOCOLPAIR("Kill pin on :", KILL_PIN); SERIAL_PROTOCOLLNPAIR(" state:", READ(KILL_PIN)); #endif SERIAL_EOL; safe_delay(50); SERIAL_PROTOCOLLNPAIR("ubl_state_at_invocation :", ubl_state_at_invocation); SERIAL_EOL; SERIAL_PROTOCOLLNPAIR("ubl_state_recursion_chk :", ubl_state_recursion_chk); SERIAL_EOL; safe_delay(50); SERIAL_PROTOCOLPAIR("Meshes go from ", hex_address((void*)settings.get_start_of_meshes())); SERIAL_PROTOCOLLNPAIR(" to ", hex_address((void*)settings.get_end_of_meshes())); safe_delay(50); SERIAL_PROTOCOLLNPAIR("sizeof(ubl) : ", (int)sizeof(ubl)); SERIAL_EOL; SERIAL_PROTOCOLLNPAIR("z_value[][] size: ", (int)sizeof(z_values)); SERIAL_EOL; safe_delay(25); SERIAL_PROTOCOLLNPAIR("EEPROM free for UBL: ", hex_address((void*)(settings.get_end_of_meshes() - settings.get_start_of_meshes()))); safe_delay(50); SERIAL_PROTOCOLPAIR("EEPROM can hold ", settings.calc_num_meshes()); SERIAL_PROTOCOLLNPGM(" meshes.\n"); safe_delay(25); if (!sanity_check()) { echo_name(); SERIAL_PROTOCOLLNPGM(" sanity checks passed."); } } /** * When we are fully debugged, the EEPROM dump command will get deleted also. But * right now, it is good to have the extra information. Soon... we prune this. */ void unified_bed_leveling::g29_eeprom_dump() { unsigned char cccc; uint16_t kkkk; SERIAL_ECHO_START; SERIAL_ECHOLNPGM("EEPROM Dump:"); for (uint16_t i = 0; i < E2END + 1; i += 16) { if (!(i & 0x3)) idle(); print_hex_word(i); SERIAL_ECHOPGM(": "); for (uint16_t j = 0; j < 16; j++) { kkkk = i + j; eeprom_read_block(&cccc, (void *)kkkk, 1); print_hex_byte(cccc); SERIAL_ECHO(' '); } SERIAL_EOL; } SERIAL_EOL; } /** * When we are fully debugged, this may go away. But there are some valid * use cases for the users. So we can wait and see what to do with it. */ void unified_bed_leveling::g29_compare_current_mesh_to_stored_mesh() { int16_t a = settings.calc_num_meshes(); if (!a) { SERIAL_PROTOCOLLNPGM("?EEPROM storage not available."); return; } if (!parser.has_value()) { SERIAL_PROTOCOLLNPGM("?Storage slot # required."); SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1); return; } g29_storage_slot = parser.value_int(); if (!WITHIN(g29_storage_slot, 0, a - 1)) { SERIAL_PROTOCOLLNPGM("?Invalid storage slot."); SERIAL_PROTOCOLLNPAIR("?Use 0 to ", a - 1); return; } float tmp_z_values[GRID_MAX_POINTS_X][GRID_MAX_POINTS_Y]; settings.load_mesh(g29_storage_slot, &tmp_z_values); SERIAL_PROTOCOLPAIR("Subtracting mesh in slot ", g29_storage_slot); SERIAL_PROTOCOLLNPGM(" from current mesh."); for (uint8_t x = 0; x < GRID_MAX_POINTS_X; x++) for (uint8_t y = 0; y < GRID_MAX_POINTS_Y; y++) z_values[x][y] -= tmp_z_values[x][y]; } mesh_index_pair unified_bed_leveling::find_closest_mesh_point_of_type(const MeshPointType type, const float &lx, const float &ly, const bool probe_as_reference, unsigned int bits[16], const bool far_flag) { mesh_index_pair out_mesh; out_mesh.x_index = out_mesh.y_index = -1; // Get our reference position. Either the nozzle or probe location. const float px = RAW_X_POSITION(lx) - (probe_as_reference == USE_PROBE_AS_REFERENCE ? X_PROBE_OFFSET_FROM_EXTRUDER : 0), py = RAW_Y_POSITION(ly) - (probe_as_reference == USE_PROBE_AS_REFERENCE ? Y_PROBE_OFFSET_FROM_EXTRUDER : 0); float best_so_far = far_flag ? -99999.99 : 99999.99; for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) { for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) { if ( (type == INVALID && isnan(z_values[i][j])) // Check to see if this location holds the right thing || (type == REAL && !isnan(z_values[i][j])) || (type == SET_IN_BITMAP && is_bit_set(bits, i, j)) ) { // We only get here if we found a Mesh Point of the specified type float raw_x = RAW_CURRENT_POSITION(X), raw_y = RAW_CURRENT_POSITION(Y); const float mx = mesh_index_to_xpos(i), my = mesh_index_to_ypos(j); // If using the probe as the reference there are some unreachable locations. // Also for round beds, there are grid points outside the bed the nozzle can't reach. // Prune them from the list and ignore them till the next Phase (manual nozzle probing). if (probe_as_reference ? !position_is_reachable_by_probe_raw_xy(mx, my) : !position_is_reachable_raw_xy(mx, my)) continue; // Reachable. Check if it's the best_so_far location to the nozzle. // Add in a weighting factor that considers the current location of the nozzle. float distance = HYPOT(px - mx, py - my); /** * If doing the far_flag action, we want to be as far as possible * from the starting point and from any other probed points. We * want the next point spread out and filling in any blank spaces * in the mesh. So we add in some of the distance to every probed * point we can find. */ if (far_flag) { for (uint8_t k = 0; k < GRID_MAX_POINTS_X; k++) { for (uint8_t l = 0; l < GRID_MAX_POINTS_Y; l++) { if (i != k && j != l && !isnan(z_values[k][l])) { //distance += pow((float) abs(i - k) * (MESH_X_DIST), 2) + pow((float) abs(j - l) * (MESH_Y_DIST), 2); // working here distance += HYPOT(MESH_X_DIST, MESH_Y_DIST) / log(HYPOT((i - k) * (MESH_X_DIST) + .001, (j - l) * (MESH_Y_DIST)) + .001); } } } } else // factor in the distance from the current location for the normal case // so the nozzle isn't running all over the bed. distance += HYPOT(raw_x - mx, raw_y - my) * 0.1; // if far_flag, look for farthest point if (far_flag == (distance > best_so_far) && distance != best_so_far) { best_so_far = distance; // We found a closer/farther location with out_mesh.x_index = i; // the specified type of mesh value. out_mesh.y_index = j; out_mesh.distance = best_so_far; } } } // for j } // for i return out_mesh; } void unified_bed_leveling::fine_tune_mesh(const float &lx, const float &ly, const bool do_ubl_mesh_map) { if (!parser.seen('R')) // fine_tune_mesh() is special. If no repetition count flag is specified g29_repetition_cnt = 1; // do exactly one mesh location. Otherwise use what the parser decided. mesh_index_pair location; uint16_t not_done[16]; if (!position_is_reachable_xy(lx, ly)) { SERIAL_PROTOCOLLNPGM("(X,Y) outside printable radius."); return; } save_ubl_active_state_and_disable(); memset(not_done, 0xFF, sizeof(not_done)); LCD_MESSAGEPGM("Fine Tuning Mesh"); // TODO: Make translatable string do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES); do_blocking_move_to_xy(lx, ly); do { location = find_closest_mesh_point_of_type(SET_IN_BITMAP, lx, ly, USE_NOZZLE_AS_REFERENCE, not_done, false); if (location.x_index < 0) break; // stop when we can't find any more reachable points. bit_clear(not_done, location.x_index, location.y_index); // Mark this location as 'adjusted' so we will find a // different location the next time through the loop const float rawx = mesh_index_to_xpos(location.x_index), rawy = mesh_index_to_ypos(location.y_index); if (!position_is_reachable_raw_xy(rawx, rawy)) // SHOULD NOT OCCUR because find_closest_mesh_point_of_type will only return reachable break; float new_z = z_values[location.x_index][location.y_index]; if (isnan(new_z)) // if the mesh point is invalid, set it to 0.0 so it can be edited new_z = 0.0; do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES); // Move the nozzle to where we are going to edit do_blocking_move_to_xy(LOGICAL_X_POSITION(rawx), LOGICAL_Y_POSITION(rawy)); new_z = floor(new_z * 1000.0) * 0.001; // Chop off digits after the 1000ths place KEEPALIVE_STATE(PAUSED_FOR_USER); has_control_of_lcd_panel = true; if (do_ubl_mesh_map) display_map(g29_map_type); // show the user which point is being adjusted lcd_implementation_clear(); lcd_mesh_edit_setup(new_z); do { new_z = lcd_mesh_edit(); #ifdef UBL_MESH_EDIT_MOVES_Z do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES + new_z); // Move the nozzle as the point is edited #endif idle(); } while (!ubl_lcd_clicked()); lcd_return_to_status(); // The technique used here generates a race condition for the encoder click. // It could get detected in lcd_mesh_edit (actually _lcd_mesh_fine_tune) or here. // Let's work on specifying a proper API for the LCD ASAP, OK? has_control_of_lcd_panel = true; // this sequence to detect an ubl_lcd_clicked() debounce it and leave if it is // a Press and Hold is repeated in a lot of places (including G26_Mesh_Validation.cpp). This // should be redone and compressed. const millis_t nxt = millis() + 1500UL; while (ubl_lcd_clicked()) { // debounce and watch for abort idle(); if (ELAPSED(millis(), nxt)) { lcd_return_to_status(); //SERIAL_PROTOCOLLNPGM("\nFine Tuning of Mesh Stopped."); do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES); LCD_MESSAGEPGM("Mesh Editing Stopped"); // TODO: Make translatable string while (ubl_lcd_clicked()) idle(); goto FINE_TUNE_EXIT; } } safe_delay(20); // We don't want any switch noise. z_values[location.x_index][location.y_index] = new_z; lcd_implementation_clear(); } while (location.x_index >= 0 && --g29_repetition_cnt > 0); FINE_TUNE_EXIT: has_control_of_lcd_panel = false; KEEPALIVE_STATE(IN_HANDLER); if (do_ubl_mesh_map) display_map(g29_map_type); restore_ubl_active_state_and_leave(); do_blocking_move_to_z(Z_CLEARANCE_BETWEEN_PROBES); do_blocking_move_to_xy(lx, ly); LCD_MESSAGEPGM("Done Editing Mesh"); // TODO: Make translatable string SERIAL_ECHOLNPGM("Done Editing Mesh"); } /** * 'Smart Fill': Scan from the outward edges of the mesh towards the center. * If an invalid location is found, use the next two points (if valid) to * calculate a 'reasonable' value for the unprobed mesh point. */ bool unified_bed_leveling::smart_fill_one(const uint8_t x, const uint8_t y, const int8_t xdir, const int8_t ydir) { const int8_t x1 = x + xdir, x2 = x1 + xdir, y1 = y + ydir, y2 = y1 + ydir; // A NAN next to a pair of real values? if (isnan(z_values[x][y]) && !isnan(z_values[x1][y1]) && !isnan(z_values[x2][y2])) { if (z_values[x1][y1] < z_values[x2][y2]) // Angled downward? z_values[x][y] = z_values[x1][y1]; // Use nearest (maybe a little too high.) else z_values[x][y] = 2.0 * z_values[x1][y1] - z_values[x2][y2]; // Angled upward... return true; } return false; } typedef struct { uint8_t sx, ex, sy, ey; bool yfirst; } smart_fill_info; void unified_bed_leveling::smart_fill_mesh() { const smart_fill_info info[] = { { 0, GRID_MAX_POINTS_X, 0, GRID_MAX_POINTS_Y - 2, false }, // Bottom of the mesh looking up { 0, GRID_MAX_POINTS_X, GRID_MAX_POINTS_Y - 1, 0, false }, // Top of the mesh looking down { 0, GRID_MAX_POINTS_X - 2, 0, GRID_MAX_POINTS_Y, true }, // Left side of the mesh looking right { GRID_MAX_POINTS_X - 1, 0, 0, GRID_MAX_POINTS_Y, true } // Right side of the mesh looking left }; for (uint8_t i = 0; i < COUNT(info); ++i) { const smart_fill_info &f = info[i]; if (f.yfirst) { const int8_t dir = f.ex > f.sx ? 1 : -1; for (uint8_t y = f.sy; y != f.ey; ++y) for (uint8_t x = f.sx; x != f.ex; x += dir) if (smart_fill_one(x, y, dir, 0)) break; } else { const int8_t dir = f.ey > f.sy ? 1 : -1; for (uint8_t x = f.sx; x != f.ex; ++x) for (uint8_t y = f.sy; y != f.ey; y += dir) if (smart_fill_one(x, y, 0, dir)) break; } } } void unified_bed_leveling::tilt_mesh_based_on_probed_grid(const bool do_ubl_mesh_map) { constexpr int16_t x_min = max(MIN_PROBE_X, UBL_MESH_MIN_X), x_max = min(MAX_PROBE_X, UBL_MESH_MAX_X), y_min = max(MIN_PROBE_Y, UBL_MESH_MIN_Y), y_max = min(MAX_PROBE_Y, UBL_MESH_MAX_Y); const float dx = float(x_max - x_min) / (g29_grid_size - 1.0), dy = float(y_max - y_min) / (g29_grid_size - 1.0); struct linear_fit_data lsf_results; incremental_LSF_reset(&lsf_results); bool zig_zag = false; for (uint8_t ix = 0; ix < g29_grid_size; ix++) { const float x = float(x_min) + ix * dx; for (int8_t iy = 0; iy < g29_grid_size; iy++) { const float y = float(y_min) + dy * (zig_zag ? g29_grid_size - 1 - iy : iy); float measured_z = probe_pt(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y), parser.seen('E'), g29_verbose_level); // TODO: Needs error handling #if ENABLED(DEBUG_LEVELING_FEATURE) if (DEBUGGING(LEVELING)) { SERIAL_CHAR('('); SERIAL_PROTOCOL_F(x, 7); SERIAL_CHAR(','); SERIAL_PROTOCOL_F(y, 7); SERIAL_ECHOPGM(") logical: "); SERIAL_CHAR('('); SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(x), 7); SERIAL_CHAR(','); SERIAL_PROTOCOL_F(LOGICAL_X_POSITION(y), 7); SERIAL_ECHOPGM(") measured: "); SERIAL_PROTOCOL_F(measured_z, 7); SERIAL_ECHOPGM(" correction: "); SERIAL_PROTOCOL_F(get_z_correction(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y)), 7); } #endif measured_z -= get_z_correction(LOGICAL_X_POSITION(x), LOGICAL_Y_POSITION(y)) /* + zprobe_zoffset */ ; #if ENABLED(DEBUG_LEVELING_FEATURE) if (DEBUGGING(LEVELING)) { SERIAL_ECHOPGM(" final >>>---> "); SERIAL_PROTOCOL_F(measured_z, 7); SERIAL_EOL; } #endif incremental_LSF(&lsf_results, x, y, measured_z); } zig_zag ^= true; } if (finish_incremental_LSF(&lsf_results)) { SERIAL_ECHOPGM("Could not complete LSF!"); return; } if (g29_verbose_level > 3) { SERIAL_ECHOPGM("LSF Results A="); SERIAL_PROTOCOL_F(lsf_results.A, 7); SERIAL_ECHOPGM(" B="); SERIAL_PROTOCOL_F(lsf_results.B, 7); SERIAL_ECHOPGM(" D="); SERIAL_PROTOCOL_F(lsf_results.D, 7); SERIAL_EOL; } vector_3 normal = vector_3(lsf_results.A, lsf_results.B, 1.0000).get_normal(); if (g29_verbose_level > 2) { SERIAL_ECHOPGM("bed plane normal = ["); SERIAL_PROTOCOL_F(normal.x, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(normal.y, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(normal.z, 7); SERIAL_ECHOLNPGM("]"); } matrix_3x3 rotation = matrix_3x3::create_look_at(vector_3(lsf_results.A, lsf_results.B, 1)); for (uint8_t i = 0; i < GRID_MAX_POINTS_X; i++) { for (uint8_t j = 0; j < GRID_MAX_POINTS_Y; j++) { float x_tmp = mesh_index_to_xpos(i), y_tmp = mesh_index_to_ypos(j), z_tmp = z_values[i][j]; #if ENABLED(DEBUG_LEVELING_FEATURE) if (DEBUGGING(LEVELING)) { SERIAL_ECHOPGM("before rotation = ["); SERIAL_PROTOCOL_F(x_tmp, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(y_tmp, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(z_tmp, 7); SERIAL_ECHOPGM("] ---> "); safe_delay(20); } #endif apply_rotation_xyz(rotation, x_tmp, y_tmp, z_tmp); #if ENABLED(DEBUG_LEVELING_FEATURE) if (DEBUGGING(LEVELING)) { SERIAL_ECHOPGM("after rotation = ["); SERIAL_PROTOCOL_F(x_tmp, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(y_tmp, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(z_tmp, 7); SERIAL_ECHOLNPGM("]"); safe_delay(55); } #endif z_values[i][j] += z_tmp - lsf_results.D; } } #if ENABLED(DEBUG_LEVELING_FEATURE) if (DEBUGGING(LEVELING)) { rotation.debug(PSTR("rotation matrix:")); SERIAL_ECHOPGM("LSF Results A="); SERIAL_PROTOCOL_F(lsf_results.A, 7); SERIAL_ECHOPGM(" B="); SERIAL_PROTOCOL_F(lsf_results.B, 7); SERIAL_ECHOPGM(" D="); SERIAL_PROTOCOL_F(lsf_results.D, 7); SERIAL_EOL; safe_delay(55); SERIAL_ECHOPGM("bed plane normal = ["); SERIAL_PROTOCOL_F(normal.x, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(normal.y, 7); SERIAL_PROTOCOLCHAR(','); SERIAL_PROTOCOL_F(normal.z, 7); SERIAL_ECHOPGM("]\n"); SERIAL_EOL; } #endif } #if ENABLED(UBL_G29_P31) void unified_bed_leveling::smart_fill_wlsf(const float &weight_factor) { // For each undefined mesh point, compute a distance-weighted least squares fit // from all the originally populated mesh points, weighted toward the point // being extrapolated so that nearby points will have greater influence on // the point being extrapolated. Then extrapolate the mesh point from WLSF. static_assert(GRID_MAX_POINTS_Y <= 16, "GRID_MAX_POINTS_Y too big"); uint16_t bitmap[GRID_MAX_POINTS_X] = { 0 }; struct linear_fit_data lsf_results; SERIAL_ECHOPGM("Extrapolating mesh..."); const float weight_scaled = weight_factor * max(MESH_X_DIST, MESH_Y_DIST); for (uint8_t jx = 0; jx < GRID_MAX_POINTS_X; jx++) for (uint8_t jy = 0; jy < GRID_MAX_POINTS_Y; jy++) if (!isnan(z_values[jx][jy])) SBI(bitmap[jx], jy); for (uint8_t ix = 0; ix < GRID_MAX_POINTS_X; ix++) { const float px = mesh_index_to_xpos(ix); for (uint8_t iy = 0; iy < GRID_MAX_POINTS_Y; iy++) { const float py = mesh_index_to_ypos(iy); if (isnan(z_values[ix][iy])) { // undefined mesh point at (px,py), compute weighted LSF from original valid mesh points. incremental_LSF_reset(&lsf_results); for (uint8_t jx = 0; jx < GRID_MAX_POINTS_X; jx++) { const float rx = mesh_index_to_xpos(jx); for (uint8_t jy = 0; jy < GRID_MAX_POINTS_Y; jy++) { if (TEST(bitmap[jx], jy)) { const float ry = mesh_index_to_ypos(jy), rz = z_values[jx][jy], w = 1.0 + weight_scaled / HYPOT((rx - px), (ry - py)); incremental_WLSF(&lsf_results, rx, ry, rz, w); } } } if (finish_incremental_LSF(&lsf_results)) { SERIAL_ECHOLNPGM("Insufficient data"); return; } const float ez = -lsf_results.D - lsf_results.A * px - lsf_results.B * py; z_values[ix][iy] = ez; idle(); // housekeeping } } } SERIAL_ECHOLNPGM("done"); } #endif // UBL_G29_P31 #endif // AUTO_BED_LEVELING_UBL