|
|
|
@ -171,8 +171,8 @@
|
|
|
|
|
|
|
|
|
|
/** Retrieves the maximum bank size in bytes of a given endpoint.
|
|
|
|
|
*
|
|
|
|
|
* \note This macro will only work correctly on endpoint indexes that are compile-time constants
|
|
|
|
|
* defined by the preprocessor.
|
|
|
|
|
* \attention This macro will only work correctly on endpoint indexes that are compile-time constants
|
|
|
|
|
* defined by the preprocessor.
|
|
|
|
|
*
|
|
|
|
|
* \param[in] EPIndex Endpoint number, a value between 0 and (\ref ENDPOINT_TOTAL_ENDPOINTS - 1)
|
|
|
|
|
*/
|
|
|
|
@ -180,8 +180,8 @@
|
|
|
|
|
|
|
|
|
|
/** Retrieves the total number of banks supported by the given endpoint.
|
|
|
|
|
*
|
|
|
|
|
* \note This macro will only work correctly on endpoint indexes that are compile-time constants
|
|
|
|
|
* defined by the preprocessor.
|
|
|
|
|
* \attention This macro will only work correctly on endpoint indexes that are compile-time constants
|
|
|
|
|
* defined by the preprocessor.
|
|
|
|
|
*
|
|
|
|
|
* \param[in] EPIndex Endpoint number, a value between 0 and (\ref ENDPOINT_TOTAL_ENDPOINTS - 1)
|
|
|
|
|
*/
|
|
|
|
@ -245,12 +245,11 @@
|
|
|
|
|
* More banks uses more USB DPRAM, but offers better performance. Isochronous type
|
|
|
|
|
* endpoints <b>must</b> have at least two banks.
|
|
|
|
|
*
|
|
|
|
|
* \note When the \c ORDERED_EP_CONFIG compile time option is used, Endpoints <b>must</b> be configured in
|
|
|
|
|
* ascending order, or bank corruption will occur.
|
|
|
|
|
* \n\n
|
|
|
|
|
* \attention When the \c ORDERED_EP_CONFIG compile time option is used, Endpoints <b>must</b> be configured in
|
|
|
|
|
* ascending order, or bank corruption will occur.
|
|
|
|
|
*
|
|
|
|
|
* \note Different endpoints may have different maximum packet sizes based on the endpoint's index - refer to
|
|
|
|
|
* the chosen microcontroller model's datasheet to determine the maximum bank size for each endpoint.
|
|
|
|
|
* \note Different endpoints may have different maximum packet sizes based on the endpoint's index - please
|
|
|
|
|
* refer to the chosen microcontroller model's datasheet to determine the maximum bank size for each endpoint.
|
|
|
|
|
* \n\n
|
|
|
|
|
*
|
|
|
|
|
* \note The default control endpoint should not be manually configured by the user application, as
|
|
|
|
@ -278,9 +277,6 @@
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
/** Indicates the number of bytes currently stored in the current endpoint's selected bank.
|
|
|
|
|
*
|
|
|
|
|
* \note The return width of this function may differ, depending on the maximum endpoint bank size
|
|
|
|
|
* of the selected AVR model.
|
|
|
|
|
*
|
|
|
|
|
* \ingroup Group_EndpointRW_AVR8
|
|
|
|
|
*
|
|
|
|
@ -835,8 +831,8 @@
|
|
|
|
|
* \c FIXED_CONTROL_ENDPOINT_SIZE token - it is recommended that the \c FIXED_CONTROL_ENDPOINT_SIZE token
|
|
|
|
|
* be used in the device descriptors to ensure this.
|
|
|
|
|
*
|
|
|
|
|
* \note This variable should be treated as read-only in the user application, and never manually
|
|
|
|
|
* changed in value.
|
|
|
|
|
* \attention This variable should be treated as read-only in the user application, and never manually
|
|
|
|
|
* changed in value.
|
|
|
|
|
*/
|
|
|
|
|
#if (!defined(FIXED_CONTROL_ENDPOINT_SIZE) || defined(__DOXYGEN__))
|
|
|
|
|
extern uint8_t USB_Device_ControlEndpointSize;
|
|
|
|
@ -848,6 +844,8 @@
|
|
|
|
|
/** Completes the status stage of a control transfer on a CONTROL type endpoint automatically,
|
|
|
|
|
* with respect to the data direction. This is a convenience function which can be used to
|
|
|
|
|
* simplify user control request handling.
|
|
|
|
|
*
|
|
|
|
|
* \note This routine should not be called on non CONTROL type endpoints.
|
|
|
|
|
*/
|
|
|
|
|
void Endpoint_ClearStatusStage(void);
|
|
|
|
|
|
|
|
|
|