You can not select more than 25 topics
Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
1222 lines
56 KiB
1222 lines
56 KiB
/*
|
|
LUFA Library
|
|
Copyright (C) Dean Camera, 2010.
|
|
|
|
dean [at] fourwalledcubicle [dot] com
|
|
www.fourwalledcubicle.com
|
|
*/
|
|
|
|
/*
|
|
Copyright 2010 Dean Camera (dean [at] fourwalledcubicle [dot] com)
|
|
|
|
Permission to use, copy, modify, distribute, and sell this
|
|
software and its documentation for any purpose is hereby granted
|
|
without fee, provided that the above copyright notice appear in
|
|
all copies and that both that the copyright notice and this
|
|
permission notice and warranty disclaimer appear in supporting
|
|
documentation, and that the name of the author not be used in
|
|
advertising or publicity pertaining to distribution of the
|
|
software without specific, written prior permission.
|
|
|
|
The author disclaim all warranties with regard to this
|
|
software, including all implied warranties of merchantability
|
|
and fitness. In no event shall the author be liable for any
|
|
special, indirect or consequential damages or any damages
|
|
whatsoever resulting from loss of use, data or profits, whether
|
|
in an action of contract, negligence or other tortious action,
|
|
arising out of or in connection with the use or performance of
|
|
this software.
|
|
*/
|
|
|
|
/** \ingroup Group_USB
|
|
* @defgroup Group_EndpointManagement Endpoint Management
|
|
*
|
|
* Functions, macros and enums related to endpoint management when in USB Device mode. This
|
|
* module contains the endpoint management macros, as well as endpoint interrupt and data
|
|
* send/receive functions for various data types.
|
|
*
|
|
* @{
|
|
*/
|
|
|
|
/** @defgroup Group_EndpointRW Endpoint Data Reading and Writing
|
|
*
|
|
* Functions, macros, variables, enums and types related to data reading and writing from and to endpoints.
|
|
*/
|
|
|
|
/** \ingroup Group_EndpointRW
|
|
* @defgroup Group_EndpointPrimitiveRW Read/Write of Primitive Data Types
|
|
*
|
|
* Functions, macros, variables, enums and types related to data reading and writing of primitive data types
|
|
* from and to endpoints.
|
|
*/
|
|
|
|
/** \ingroup Group_EndpointRW
|
|
* @defgroup Group_EndpointStreamRW Read/Write of Multi-Byte Streams
|
|
*
|
|
* Functions, macros, variables, enums and types related to data reading and writing of data streams from
|
|
* and to endpoints.
|
|
*/
|
|
|
|
/** @defgroup Group_EndpointPacketManagement Endpoint Packet Management
|
|
*
|
|
* Functions, macros, variables, enums and types related to packet management of endpoints.
|
|
*/
|
|
|
|
#ifndef __ENDPOINT_H__
|
|
#define __ENDPOINT_H__
|
|
|
|
/* Includes: */
|
|
#include <avr/io.h>
|
|
#include <avr/pgmspace.h>
|
|
#include <avr/eeprom.h>
|
|
#include <stdbool.h>
|
|
|
|
#include "../../../Common/Common.h"
|
|
#include "../HighLevel/USBTask.h"
|
|
|
|
#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
|
|
#include "../HighLevel/StreamCallbacks.h"
|
|
#endif
|
|
|
|
/* Enable C linkage for C++ Compilers: */
|
|
#if defined(__cplusplus)
|
|
extern "C" {
|
|
#endif
|
|
|
|
/* Public Interface - May be used in end-application: */
|
|
/* Macros: */
|
|
/** Endpoint data direction mask for \ref Endpoint_ConfigureEndpoint(). This indicates that the endpoint
|
|
* should be initialized in the OUT direction - i.e. data flows from host to device.
|
|
*/
|
|
#define ENDPOINT_DIR_OUT (0 << EPDIR)
|
|
|
|
/** Endpoint data direction mask for \ref Endpoint_ConfigureEndpoint(). This indicates that the endpoint
|
|
* should be initialized in the IN direction - i.e. data flows from device to host.
|
|
*/
|
|
#define ENDPOINT_DIR_IN (1 << EPDIR)
|
|
|
|
/** Mask for the bank mode selection for the \ref Endpoint_ConfigureEndpoint() macro. This indicates
|
|
* that the endpoint should have one single bank, which requires less USB FIFO memory but results
|
|
* in slower transfers as only one USB device (the AVR or the host) can access the endpoint's
|
|
* bank at the one time.
|
|
*/
|
|
#define ENDPOINT_BANK_SINGLE (0 << EPBK0)
|
|
|
|
/** Mask for the bank mode selection for the \ref Endpoint_ConfigureEndpoint() macro. This indicates
|
|
* that the endpoint should have two banks, which requires more USB FIFO memory but results
|
|
* in faster transfers as one USB device (the AVR or the host) can access one bank while the other
|
|
* accesses the second bank.
|
|
*/
|
|
#define ENDPOINT_BANK_DOUBLE (1 << EPBK0)
|
|
|
|
/** Endpoint address for the default control endpoint, which always resides in address 0. This is
|
|
* defined for convenience to give more readable code when used with the endpoint macros.
|
|
*/
|
|
#define ENDPOINT_CONTROLEP 0
|
|
|
|
#if (!defined(FIXED_CONTROL_ENDPOINT_SIZE) || defined(__DOXYGEN__))
|
|
/** Default size of the default control endpoint's bank, until altered by the Endpoint0Size value
|
|
* in the device descriptor. Not available if the FIXED_CONTROL_ENDPOINT_SIZE token is defined.
|
|
*/
|
|
#define ENDPOINT_CONTROLEP_DEFAULT_SIZE 8
|
|
#endif
|
|
|
|
/** Endpoint number mask, for masking against endpoint addresses to retrieve the endpoint's
|
|
* numerical address in the device.
|
|
*/
|
|
#define ENDPOINT_EPNUM_MASK 0x07
|
|
|
|
/** Endpoint bank size mask, for masking against endpoint addresses to retrieve the endpoint's
|
|
* bank size in the device.
|
|
*/
|
|
#define ENDPOINT_EPSIZE_MASK 0x7FF
|
|
|
|
/** Maximum size in bytes of a given endpoint.
|
|
*
|
|
* \param[in] n Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)
|
|
*/
|
|
#define ENDPOINT_MAX_SIZE(n) _ENDPOINT_GET_MAXSIZE(n)
|
|
|
|
/** Indicates if the given endpoint supports double banking.
|
|
*
|
|
* \param[in] n Endpoint number, a value between 0 and (ENDPOINT_TOTAL_ENDPOINTS - 1)
|
|
*/
|
|
#define ENDPOINT_DOUBLEBANK_SUPPORTED(n) _ENDPOINT_GET_DOUBLEBANK(n)
|
|
|
|
#if !defined(CONTROL_ONLY_DEVICE)
|
|
#if defined(USB_SERIES_4_AVR) || defined(USB_SERIES_6_AVR) || defined(USB_SERIES_7_AVR) || defined(__DOXYGEN__)
|
|
/** Total number of endpoints (including the default control endpoint at address 0) which may
|
|
* be used in the device. Different USB AVR models support different amounts of endpoints,
|
|
* this value reflects the maximum number of endpoints for the currently selected AVR model.
|
|
*/
|
|
#define ENDPOINT_TOTAL_ENDPOINTS 7
|
|
#else
|
|
#define ENDPOINT_TOTAL_ENDPOINTS 5
|
|
#endif
|
|
#else
|
|
#define ENDPOINT_TOTAL_ENDPOINTS 1
|
|
#endif
|
|
|
|
/* Pseudo-Function Macros: */
|
|
#if defined(__DOXYGEN__)
|
|
/** Indicates the number of bytes currently stored in the current endpoint's selected bank.
|
|
*
|
|
* \note The return width of this function may differ, depending on the maximum endpoint bank size
|
|
* of the selected AVR model.
|
|
*
|
|
* \ingroup Group_EndpointRW
|
|
*
|
|
* \return Total number of bytes in the currently selected Endpoint's FIFO buffer
|
|
*/
|
|
static inline uint16_t Endpoint_BytesInEndpoint(void);
|
|
|
|
/** Get the endpoint address of the currently selected endpoint. This is typically used to save
|
|
* the currently selected endpoint number so that it can be restored after another endpoint has
|
|
* been manipulated.
|
|
*
|
|
* \return Index of the currently selected endpoint
|
|
*/
|
|
static inline uint8_t Endpoint_GetCurrentEndpoint(void);
|
|
|
|
/** Selects the given endpoint number. If the address from the device descriptors is used, the
|
|
* value should be masked with the \ref ENDPOINT_EPNUM_MASK constant to extract only the endpoint
|
|
* number (and discarding the endpoint direction bit).
|
|
*
|
|
* Any endpoint operations which do not require the endpoint number to be indicated will operate on
|
|
* the currently selected endpoint.
|
|
*
|
|
* \param[in] EndpointNumber Endpoint number to select
|
|
*/
|
|
static inline void Endpoint_SelectEndpoint(uint8_t EndpointNumber);
|
|
|
|
/** Resets the endpoint bank FIFO. This clears all the endpoint banks and resets the USB controller's
|
|
* In and Out pointers to the bank's contents.
|
|
*
|
|
* \param[in] EndpointNumber Endpoint number whose FIFO buffers are to be reset
|
|
*/
|
|
static inline void Endpoint_ResetFIFO(uint8_t EndpointNumber);
|
|
|
|
/** Enables the currently selected endpoint so that data can be sent and received through it to
|
|
* and from a host.
|
|
*
|
|
* \note Endpoints must first be configured properly via \ref Endpoint_ConfigureEndpoint().
|
|
*/
|
|
static inline void Endpoint_EnableEndpoint(void);
|
|
|
|
/** Disables the currently selected endpoint so that data cannot be sent and received through it
|
|
* to and from a host.
|
|
*/
|
|
static inline void Endpoint_DisableEndpoint(void);
|
|
|
|
/** Determines if the currently selected endpoint is enabled, but not necessarily configured.
|
|
*
|
|
* \return Boolean True if the currently selected endpoint is enabled, false otherwise
|
|
*/
|
|
static inline bool Endpoint_IsEnabled(void);
|
|
|
|
/** Determines if the currently selected endpoint may be read from (if data is waiting in the endpoint
|
|
* bank and the endpoint is an OUT direction, or if the bank is not yet full if the endpoint is an IN
|
|
* direction). This function will return false if an error has occurred in the endpoint, if the endpoint
|
|
* is an OUT direction and no packet (or an empty packet) has been received, or if the endpoint is an IN
|
|
* direction and the endpoint bank is full.
|
|
*
|
|
* \ingroup Group_EndpointPacketManagement
|
|
*
|
|
* \return Boolean true if the currently selected endpoint may be read from or written to, depending on its direction
|
|
*/
|
|
static inline bool Endpoint_IsReadWriteAllowed(void);
|
|
|
|
/** Determines if the currently selected endpoint is configured.
|
|
*
|
|
* \return Boolean true if the currently selected endpoint has been configured, false otherwise
|
|
*/
|
|
static inline bool Endpoint_IsConfigured(void);
|
|
|
|
/** Returns a mask indicating which INTERRUPT type endpoints have interrupted - i.e. their
|
|
* interrupt duration has elapsed. Which endpoints have interrupted can be determined by
|
|
* masking the return value against (1 << {Endpoint Number}).
|
|
*
|
|
* \return Mask whose bits indicate which endpoints have interrupted
|
|
*/
|
|
static inline uint8_t Endpoint_GetEndpointInterrupts(void);
|
|
|
|
/** Determines if the specified endpoint number has interrupted (valid only for INTERRUPT type
|
|
* endpoints).
|
|
*
|
|
* \param[in] EndpointNumber Index of the endpoint whose interrupt flag should be tested
|
|
*
|
|
* \return Boolean true if the specified endpoint has interrupted, false otherwise
|
|
*/
|
|
static inline bool Endpoint_HasEndpointInterrupted(uint8_t EndpointNumber);
|
|
|
|
/** Determines if the selected IN endpoint is ready for a new packet.
|
|
*
|
|
* \ingroup Group_EndpointPacketManagement
|
|
*
|
|
* \return Boolean true if the current endpoint is ready for an IN packet, false otherwise.
|
|
*/
|
|
static inline bool Endpoint_IsINReady(void);
|
|
|
|
/** Determines if the selected OUT endpoint has received new packet.
|
|
*
|
|
* \ingroup Group_EndpointPacketManagement
|
|
*
|
|
* \return Boolean true if current endpoint is has received an OUT packet, false otherwise.
|
|
*/
|
|
static inline bool Endpoint_IsOUTReceived(void);
|
|
|
|
/** Determines if the current CONTROL type endpoint has received a SETUP packet.
|
|
*
|
|
* \ingroup Group_EndpointPacketManagement
|
|
*
|
|
* \return Boolean true if the selected endpoint has received a SETUP packet, false otherwise.
|
|
*/
|
|
static inline bool Endpoint_IsSETUPReceived(void);
|
|
|
|
/** Clears a received SETUP packet on the currently selected CONTROL type endpoint, freeing up the
|
|
* endpoint for the next packet.
|
|
*
|
|
* \ingroup Group_EndpointPacketManagement
|
|
*
|
|
* \note This is not applicable for non CONTROL type endpoints.
|
|
*/
|
|
static inline void Endpoint_ClearSETUP(void);
|
|
|
|
/** Sends an IN packet to the host on the currently selected endpoint, freeing up the endpoint for the
|
|
* next packet and switching to the alternative endpoint bank if double banked.
|
|
*
|
|
* \ingroup Group_EndpointPacketManagement
|
|
*/
|
|
static inline void Endpoint_ClearIN(void);
|
|
|
|
/** Acknowledges an OUT packet to the host on the currently selected endpoint, freeing up the endpoint
|
|
* for the next packet and switching to the alternative endpoint bank if double banked.
|
|
*
|
|
* \ingroup Group_EndpointPacketManagement
|
|
*/
|
|
static inline void Endpoint_ClearOUT(void);
|
|
|
|
/** Stalls the current endpoint, indicating to the host that a logical problem occurred with the
|
|
* indicated endpoint and that the current transfer sequence should be aborted. This provides a
|
|
* way for devices to indicate invalid commands to the host so that the current transfer can be
|
|
* aborted and the host can begin its own recovery sequence.
|
|
*
|
|
* The currently selected endpoint remains stalled until either the \ref Endpoint_ClearStall() macro
|
|
* is called, or the host issues a CLEAR FEATURE request to the device for the currently selected
|
|
* endpoint.
|
|
*
|
|
* \ingroup Group_EndpointPacketManagement
|
|
*/
|
|
static inline void Endpoint_StallTransaction(void);
|
|
|
|
/** Clears the STALL condition on the currently selected endpoint.
|
|
*
|
|
* \ingroup Group_EndpointPacketManagement
|
|
*/
|
|
static inline void Endpoint_ClearStall(void);
|
|
|
|
/** Determines if the currently selected endpoint is stalled, false otherwise.
|
|
*
|
|
* \ingroup Group_EndpointPacketManagement
|
|
*
|
|
* \return Boolean true if the currently selected endpoint is stalled, false otherwise
|
|
*/
|
|
static inline bool Endpoint_IsStalled(void);
|
|
|
|
/** Resets the data toggle of the currently selected endpoint. */
|
|
static inline void Endpoint_ResetDataToggle(void);
|
|
|
|
/** Determines the currently selected endpoint's direction.
|
|
*
|
|
* \return The currently selected endpoint's direction, as a ENDPOINT_DIR_* mask.
|
|
*/
|
|
static inline uint8_t Endpoint_GetEndpointDirection(void);
|
|
|
|
/** Sets the direction of the currently selected endpoint.
|
|
*
|
|
* \param[in] DirectionMask New endpoint direction, as a ENDPOINT_DIR_* mask.
|
|
*/
|
|
static inline void Endpoint_SetEndpointDirection(uint8_t DirectionMask);
|
|
#else
|
|
#if defined(USB_SERIES_6_AVR) || defined(USB_SERIES_7_AVR)
|
|
#define Endpoint_BytesInEndpoint() UEBCX
|
|
#elif defined(USB_SERIES_4_AVR)
|
|
#define Endpoint_BytesInEndpoint() (((uint16_t)UEBCHX << 8) | UEBCLX)
|
|
#elif defined(USB_SERIES_2_AVR)
|
|
#define Endpoint_BytesInEndpoint() UEBCLX
|
|
#endif
|
|
|
|
#if !defined(CONTROL_ONLY_DEVICE)
|
|
#define Endpoint_GetCurrentEndpoint() (UENUM & ENDPOINT_EPNUM_MASK)
|
|
#else
|
|
#define Endpoint_GetCurrentEndpoint() ENDPOINT_CONTROLEP
|
|
#endif
|
|
|
|
#if !defined(CONTROL_ONLY_DEVICE)
|
|
#define Endpoint_SelectEndpoint(epnum) MACROS{ UENUM = (epnum); }MACROE
|
|
#else
|
|
#define Endpoint_SelectEndpoint(epnum) (void)(epnum)
|
|
#endif
|
|
|
|
#define Endpoint_ResetFIFO(epnum) MACROS{ UERST = (1 << (epnum)); UERST = 0; }MACROE
|
|
|
|
#define Endpoint_EnableEndpoint() MACROS{ UECONX |= (1 << EPEN); }MACROE
|
|
|
|
#define Endpoint_DisableEndpoint() MACROS{ UECONX &= ~(1 << EPEN); }MACROE
|
|
|
|
#define Endpoint_IsEnabled() ((UECONX & (1 << EPEN)) ? true : false)
|
|
|
|
#if !defined(CONTROL_ONLY_DEVICE)
|
|
#define Endpoint_IsReadWriteAllowed() ((UEINTX & (1 << RWAL)) ? true : false)
|
|
#endif
|
|
|
|
#define Endpoint_IsConfigured() ((UESTA0X & (1 << CFGOK)) ? true : false)
|
|
|
|
#define Endpoint_GetEndpointInterrupts() UEINT
|
|
|
|
#define Endpoint_HasEndpointInterrupted(n) ((UEINT & (1 << (n))) ? true : false)
|
|
|
|
#define Endpoint_IsINReady() ((UEINTX & (1 << TXINI)) ? true : false)
|
|
|
|
#define Endpoint_IsOUTReceived() ((UEINTX & (1 << RXOUTI)) ? true : false)
|
|
|
|
#define Endpoint_IsSETUPReceived() ((UEINTX & (1 << RXSTPI)) ? true : false)
|
|
|
|
#define Endpoint_ClearSETUP() MACROS{ UEINTX &= ~(1 << RXSTPI); }MACROE
|
|
|
|
#if !defined(CONTROL_ONLY_DEVICE)
|
|
#define Endpoint_ClearIN() MACROS{ uint8_t Temp = UEINTX; UEINTX = (Temp & ~(1 << TXINI)); \
|
|
UEINTX = (Temp & ~(1 << FIFOCON)); }MACROE
|
|
#else
|
|
#define Endpoint_ClearIN() MACROS{ UEINTX &= ~(1 << TXINI); }MACROE
|
|
#endif
|
|
|
|
#if !defined(CONTROL_ONLY_DEVICE)
|
|
#define Endpoint_ClearOUT() MACROS{ uint8_t Temp = UEINTX; UEINTX = (Temp & ~(1 << RXOUTI)); \
|
|
UEINTX = (Temp & ~(1 << FIFOCON)); }MACROE
|
|
#else
|
|
#define Endpoint_ClearOUT() MACROS{ UEINTX &= ~(1 << RXOUTI); }MACROE
|
|
#endif
|
|
|
|
#define Endpoint_StallTransaction() MACROS{ UECONX |= (1 << STALLRQ); }MACROE
|
|
|
|
#define Endpoint_ClearStall() MACROS{ UECONX |= (1 << STALLRQC); }MACROE
|
|
|
|
#define Endpoint_IsStalled() ((UECONX & (1 << STALLRQ)) ? true : false)
|
|
|
|
#define Endpoint_ResetDataToggle() MACROS{ UECONX |= (1 << RSTDT); }MACROE
|
|
|
|
#define Endpoint_GetEndpointDirection() (UECFG0X & ENDPOINT_DIR_IN)
|
|
|
|
#define Endpoint_SetEndpointDirection(dir) MACROS{ UECFG0X = ((UECFG0X & ~ENDPOINT_DIR_IN) | (dir)); }MACROE
|
|
#endif
|
|
|
|
/* Enums: */
|
|
/** Enum for the possible error return codes of the \ref Endpoint_WaitUntilReady() function.
|
|
*
|
|
* \ingroup Group_EndpointRW
|
|
*/
|
|
enum Endpoint_WaitUntilReady_ErrorCodes_t
|
|
{
|
|
ENDPOINT_READYWAIT_NoError = 0, /**< Endpoint is ready for next packet, no error. */
|
|
ENDPOINT_READYWAIT_EndpointStalled = 1, /**< The endpoint was stalled during the stream
|
|
* transfer by the host or device.
|
|
*/
|
|
ENDPOINT_READYWAIT_DeviceDisconnected = 2, /**< Device was disconnected from the host while
|
|
* waiting for the endpoint to become ready.
|
|
*/
|
|
ENDPOINT_READYWAIT_Timeout = 3, /**< The host failed to accept or send the next packet
|
|
* within the software timeout period set by the
|
|
* \ref USB_STREAM_TIMEOUT_MS macro.
|
|
*/
|
|
};
|
|
|
|
/** Enum for the possible error return codes of the Endpoint_*_Stream_* functions.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*/
|
|
enum Endpoint_Stream_RW_ErrorCodes_t
|
|
{
|
|
ENDPOINT_RWSTREAM_NoError = 0, /**< Command completed successfully, no error. */
|
|
ENDPOINT_RWSTREAM_EndpointStalled = 1, /**< The endpoint was stalled during the stream
|
|
* transfer by the host or device.
|
|
*/
|
|
ENDPOINT_RWSTREAM_DeviceDisconnected = 2, /**< Device was disconnected from the host during
|
|
* the transfer.
|
|
*/
|
|
ENDPOINT_RWSTREAM_Timeout = 3, /**< The host failed to accept or send the next packet
|
|
* within the software timeout period set by the
|
|
* \ref USB_STREAM_TIMEOUT_MS macro.
|
|
*/
|
|
ENDPOINT_RWSTREAM_CallbackAborted = 4, /**< Indicates that the stream's callback function
|
|
* aborted the transfer early.
|
|
*/
|
|
};
|
|
|
|
/** Enum for the possible error return codes of the Endpoint_*_Control_Stream_* functions..
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*/
|
|
enum Endpoint_ControlStream_RW_ErrorCodes_t
|
|
{
|
|
ENDPOINT_RWCSTREAM_NoError = 0, /**< Command completed successfully, no error. */
|
|
ENDPOINT_RWCSTREAM_HostAborted = 1, /**< The aborted the transfer prematurely. */
|
|
ENDPOINT_RWCSTREAM_DeviceDisconnected = 2, /**< Device was disconnected from the host during
|
|
* the transfer.
|
|
*/
|
|
};
|
|
|
|
/* Inline Functions: */
|
|
/** Reads one byte from the currently selected endpoint's bank, for OUT direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*
|
|
* \return Next byte in the currently selected endpoint's FIFO buffer
|
|
*/
|
|
static inline uint8_t Endpoint_Read_Byte(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
|
|
static inline uint8_t Endpoint_Read_Byte(void)
|
|
{
|
|
return UEDATX;
|
|
}
|
|
|
|
/** Writes one byte from the currently selected endpoint's bank, for IN direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*
|
|
* \param[in] Byte Next byte to write into the the currently selected endpoint's FIFO buffer
|
|
*/
|
|
static inline void Endpoint_Write_Byte(const uint8_t Byte) ATTR_ALWAYS_INLINE;
|
|
static inline void Endpoint_Write_Byte(const uint8_t Byte)
|
|
{
|
|
UEDATX = Byte;
|
|
}
|
|
|
|
/** Discards one byte from the currently selected endpoint's bank, for OUT direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*/
|
|
static inline void Endpoint_Discard_Byte(void) ATTR_ALWAYS_INLINE;
|
|
static inline void Endpoint_Discard_Byte(void)
|
|
{
|
|
uint8_t Dummy;
|
|
|
|
Dummy = UEDATX;
|
|
}
|
|
|
|
/** Reads two bytes from the currently selected endpoint's bank in little endian format, for OUT
|
|
* direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*
|
|
* \return Next word in the currently selected endpoint's FIFO buffer
|
|
*/
|
|
static inline uint16_t Endpoint_Read_Word_LE(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
|
|
static inline uint16_t Endpoint_Read_Word_LE(void)
|
|
{
|
|
union
|
|
{
|
|
uint16_t Word;
|
|
uint8_t Bytes[2];
|
|
} Data;
|
|
|
|
Data.Bytes[0] = UEDATX;
|
|
Data.Bytes[1] = UEDATX;
|
|
|
|
return Data.Word;
|
|
}
|
|
|
|
/** Reads two bytes from the currently selected endpoint's bank in big endian format, for OUT
|
|
* direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*
|
|
* \return Next word in the currently selected endpoint's FIFO buffer
|
|
*/
|
|
static inline uint16_t Endpoint_Read_Word_BE(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
|
|
static inline uint16_t Endpoint_Read_Word_BE(void)
|
|
{
|
|
union
|
|
{
|
|
uint16_t Word;
|
|
uint8_t Bytes[2];
|
|
} Data;
|
|
|
|
Data.Bytes[1] = UEDATX;
|
|
Data.Bytes[0] = UEDATX;
|
|
|
|
return Data.Word;
|
|
}
|
|
|
|
/** Writes two bytes to the currently selected endpoint's bank in little endian format, for IN
|
|
* direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*
|
|
* \param[in] Word Next word to write to the currently selected endpoint's FIFO buffer
|
|
*/
|
|
static inline void Endpoint_Write_Word_LE(const uint16_t Word) ATTR_ALWAYS_INLINE;
|
|
static inline void Endpoint_Write_Word_LE(const uint16_t Word)
|
|
{
|
|
UEDATX = (Word & 0xFF);
|
|
UEDATX = (Word >> 8);
|
|
}
|
|
|
|
/** Writes two bytes to the currently selected endpoint's bank in big endian format, for IN
|
|
* direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*
|
|
* \param[in] Word Next word to write to the currently selected endpoint's FIFO buffer
|
|
*/
|
|
static inline void Endpoint_Write_Word_BE(const uint16_t Word) ATTR_ALWAYS_INLINE;
|
|
static inline void Endpoint_Write_Word_BE(const uint16_t Word)
|
|
{
|
|
UEDATX = (Word >> 8);
|
|
UEDATX = (Word & 0xFF);
|
|
}
|
|
|
|
/** Discards two bytes from the currently selected endpoint's bank, for OUT direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*/
|
|
static inline void Endpoint_Discard_Word(void) ATTR_ALWAYS_INLINE;
|
|
static inline void Endpoint_Discard_Word(void)
|
|
{
|
|
uint8_t Dummy;
|
|
|
|
Dummy = UEDATX;
|
|
Dummy = UEDATX;
|
|
}
|
|
|
|
/** Reads four bytes from the currently selected endpoint's bank in little endian format, for OUT
|
|
* direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*
|
|
* \return Next double word in the currently selected endpoint's FIFO buffer
|
|
*/
|
|
static inline uint32_t Endpoint_Read_DWord_LE(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
|
|
static inline uint32_t Endpoint_Read_DWord_LE(void)
|
|
{
|
|
union
|
|
{
|
|
uint32_t DWord;
|
|
uint8_t Bytes[4];
|
|
} Data;
|
|
|
|
Data.Bytes[0] = UEDATX;
|
|
Data.Bytes[1] = UEDATX;
|
|
Data.Bytes[2] = UEDATX;
|
|
Data.Bytes[3] = UEDATX;
|
|
|
|
return Data.DWord;
|
|
}
|
|
|
|
/** Reads four bytes from the currently selected endpoint's bank in big endian format, for OUT
|
|
* direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*
|
|
* \return Next double word in the currently selected endpoint's FIFO buffer
|
|
*/
|
|
static inline uint32_t Endpoint_Read_DWord_BE(void) ATTR_WARN_UNUSED_RESULT ATTR_ALWAYS_INLINE;
|
|
static inline uint32_t Endpoint_Read_DWord_BE(void)
|
|
{
|
|
union
|
|
{
|
|
uint32_t DWord;
|
|
uint8_t Bytes[4];
|
|
} Data;
|
|
|
|
Data.Bytes[3] = UEDATX;
|
|
Data.Bytes[2] = UEDATX;
|
|
Data.Bytes[1] = UEDATX;
|
|
Data.Bytes[0] = UEDATX;
|
|
|
|
return Data.DWord;
|
|
}
|
|
|
|
/** Writes four bytes to the currently selected endpoint's bank in little endian format, for IN
|
|
* direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*
|
|
* \param[in] DWord Next double word to write to the currently selected endpoint's FIFO buffer
|
|
*/
|
|
static inline void Endpoint_Write_DWord_LE(const uint32_t DWord) ATTR_ALWAYS_INLINE;
|
|
static inline void Endpoint_Write_DWord_LE(const uint32_t DWord)
|
|
{
|
|
UEDATX = (DWord & 0xFF);
|
|
UEDATX = (DWord >> 8);
|
|
UEDATX = (DWord >> 16);
|
|
UEDATX = (DWord >> 24);
|
|
}
|
|
|
|
/** Writes four bytes to the currently selected endpoint's bank in big endian format, for IN
|
|
* direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*
|
|
* \param[in] DWord Next double word to write to the currently selected endpoint's FIFO buffer
|
|
*/
|
|
static inline void Endpoint_Write_DWord_BE(const uint32_t DWord) ATTR_ALWAYS_INLINE;
|
|
static inline void Endpoint_Write_DWord_BE(const uint32_t DWord)
|
|
{
|
|
UEDATX = (DWord >> 24);
|
|
UEDATX = (DWord >> 16);
|
|
UEDATX = (DWord >> 8);
|
|
UEDATX = (DWord & 0xFF);
|
|
}
|
|
|
|
/** Discards four bytes from the currently selected endpoint's bank, for OUT direction endpoints.
|
|
*
|
|
* \ingroup Group_EndpointPrimitiveRW
|
|
*/
|
|
static inline void Endpoint_Discard_DWord(void) ATTR_ALWAYS_INLINE;
|
|
static inline void Endpoint_Discard_DWord(void)
|
|
{
|
|
uint8_t Dummy;
|
|
|
|
Dummy = UEDATX;
|
|
Dummy = UEDATX;
|
|
Dummy = UEDATX;
|
|
Dummy = UEDATX;
|
|
}
|
|
|
|
/* External Variables: */
|
|
/** Global indicating the maximum packet size of the default control endpoint located at address
|
|
* 0 in the device. This value is set to the value indicated in the device descriptor in the user
|
|
* project once the USB interface is initialized into device mode.
|
|
*
|
|
* If space is an issue, it is possible to fix this to a static value by defining the control
|
|
* endpoint size in the FIXED_CONTROL_ENDPOINT_SIZE token passed to the compiler in the makefile
|
|
* via the -D switch. When a fixed control endpoint size is used, the size is no longer dynamically
|
|
* read from the descriptors at runtime and instead fixed to the given value. When used, it is
|
|
* important that the descriptor control endpoint size value matches the size given as the
|
|
* FIXED_CONTROL_ENDPOINT_SIZE token - it is recommended that the FIXED_CONTROL_ENDPOINT_SIZE token
|
|
* be used in the descriptors to ensure this.
|
|
*
|
|
* \note This variable should be treated as read-only in the user application, and never manually
|
|
* changed in value.
|
|
*/
|
|
#if (!defined(FIXED_CONTROL_ENDPOINT_SIZE) || defined(__DOXYGEN__))
|
|
extern uint8_t USB_ControlEndpointSize;
|
|
#else
|
|
#define USB_ControlEndpointSize FIXED_CONTROL_ENDPOINT_SIZE
|
|
#endif
|
|
|
|
/* Function Prototypes: */
|
|
#if !defined(NO_STREAM_CALLBACKS) || defined(__DOXYGEN__)
|
|
#define __CALLBACK_PARAM , StreamCallbackPtr_t Callback
|
|
#else
|
|
#define __CALLBACK_PARAM
|
|
#endif
|
|
|
|
/** Configures the specified endpoint number with the given endpoint type, direction, bank size
|
|
* and banking mode. Endpoints should be allocated in ascending order by their address in the
|
|
* device (i.e. endpoint 1 should be configured before endpoint 2 and so on) to prevent fragmentation
|
|
* of the USB FIFO memory.
|
|
*
|
|
* The endpoint type may be one of the EP_TYPE_* macros listed in LowLevel.h and the direction
|
|
* may be either \ref ENDPOINT_DIR_OUT or \ref ENDPOINT_DIR_IN.
|
|
*
|
|
* The bank size must indicate the maximum packet size that the endpoint can handle. Different
|
|
* endpoint numbers can handle different maximum packet sizes - refer to the chosen USB AVR's
|
|
* datasheet to determine the maximum bank size for each endpoint.
|
|
*
|
|
* The banking mode may be either \ref ENDPOINT_BANK_SINGLE or \ref ENDPOINT_BANK_DOUBLE.
|
|
*
|
|
* \note The default control endpoint does not have to be manually configured, as it is automatically
|
|
* configured by the library internally.
|
|
*
|
|
* \note This routine will select the specified endpoint, and the endpoint will remain selected
|
|
* once the routine completes regardless of if the endpoint configuration succeeds.
|
|
*
|
|
* \return Boolean true if the configuration succeeded, false otherwise
|
|
*/
|
|
bool Endpoint_ConfigureEndpoint(const uint8_t Number, const uint8_t Type, const uint8_t Direction,
|
|
const uint16_t Size, const uint8_t Banks);
|
|
|
|
/** Spin-loops until the currently selected non-control endpoint is ready for the next packet of data
|
|
* to be read or written to it.
|
|
*
|
|
* \note This routine should not be called on CONTROL type endpoints.
|
|
*
|
|
* \ingroup Group_EndpointRW
|
|
*
|
|
* \return A value from the \ref Endpoint_WaitUntilReady_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_WaitUntilReady(void);
|
|
|
|
/** Completes the status stage of a control transfer on a CONTROL type endpoint automatically,
|
|
* with respect to the data direction. This is a convenience function which can be used to
|
|
* simplify user control request handling.
|
|
*/
|
|
void Endpoint_ClearStatusStage(void);
|
|
|
|
/** Reads and discards the given number of bytes from the endpoint from the given buffer,
|
|
* discarding fully read packets from the host as needed. The last packet is not automatically
|
|
* discarded once the remaining bytes has been read; the user is responsible for manually
|
|
* discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
|
|
* each USB packet, the given stream callback function is executed repeatedly until the next
|
|
* packet is ready, allowing for early aborts of stream transfers.
|
|
*
|
|
* The callback routine should be created according to the information in \ref Group_StreamCallbacks.
|
|
* If the token NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are
|
|
* disabled and this function has the Callback parameter omitted.
|
|
*
|
|
* \note This routine should not be used on CONTROL type endpoints.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Length Number of bytes to send via the currently selected endpoint.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Discard_Stream(uint16_t Length __CALLBACK_PARAM);
|
|
|
|
/** Writes the given number of bytes to the endpoint from the given buffer in little endian,
|
|
* sending full packets to the host as needed. The last packet filled is not automatically sent;
|
|
* the user is responsible for manually sending the last written packet to the host via the
|
|
* \ref Endpoint_ClearIN() macro. Between each USB packet, the given stream callback function
|
|
* is executed repeatedly until the endpoint is ready to accept the next packet, allowing for early
|
|
* aborts of stream transfers.
|
|
*
|
|
* The callback routine should be created according to the information in \ref Group_StreamCallbacks.
|
|
* If the token NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are
|
|
* disabled and this function has the Callback parameter omitted.
|
|
*
|
|
* \note This routine should not be used on CONTROL type endpoints.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_Stream_LE(const void* Buffer, uint16_t Length __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** EEPROM buffer source version of \ref Endpoint_Write_Stream_LE().
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_EStream_LE(const void* Buffer, uint16_t Length __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** FLASH buffer source version of \ref Endpoint_Write_Stream_LE().
|
|
*
|
|
* \note The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_PStream_LE(const void* Buffer, uint16_t Length __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** Writes the given number of bytes to the endpoint from the given buffer in big endian,
|
|
* sending full packets to the host as needed. The last packet filled is not automatically sent;
|
|
* the user is responsible for manually sending the last written packet to the host via the
|
|
* \ref Endpoint_ClearIN() macro. Between each USB packet, the given stream callback function
|
|
* is executed repeatedly until the endpoint is ready to accept the next packet, allowing for early
|
|
* aborts of stream transfers.
|
|
*
|
|
* The callback routine should be created according to the information in \ref Group_StreamCallbacks.
|
|
* If the token NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are
|
|
* disabled and this function has the Callback parameter omitted.
|
|
*
|
|
* \note This routine should not be used on CONTROL type endpoints.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_Stream_BE(const void* Buffer, uint16_t Length __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** EEPROM buffer source version of \ref Endpoint_Write_Stream_BE().
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_EStream_BE(const void* Buffer, uint16_t Length __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** FLASH buffer source version of \ref Endpoint_Write_Stream_BE().
|
|
*
|
|
* \note The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_PStream_BE(const void* Buffer, uint16_t Length __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** Reads the given number of bytes from the endpoint from the given buffer in little endian,
|
|
* discarding fully read packets from the host as needed. The last packet is not automatically
|
|
* discarded once the remaining bytes has been read; the user is responsible for manually
|
|
* discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
|
|
* each USB packet, the given stream callback function is executed repeatedly until the endpoint
|
|
* is ready to accept the next packet, allowing for early aborts of stream transfers.
|
|
*
|
|
* The callback routine should be created according to the information in \ref Group_StreamCallbacks.
|
|
* If the token NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are
|
|
* disabled and this function has the Callback parameter omitted.
|
|
*
|
|
* \note This routine should not be used on CONTROL type endpoints.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[out] Buffer Pointer to the destination data buffer to write to.
|
|
* \param[in] Length Number of bytes to send via the currently selected endpoint.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Read_Stream_LE(void* Buffer, uint16_t Length __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** EEPROM buffer source version of \ref Endpoint_Read_Stream_LE().
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[out] Buffer Pointer to the destination data buffer to write to, located in EEPROM memory space.
|
|
* \param[in] Length Number of bytes to send via the currently selected endpoint.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Read_EStream_LE(void* Buffer, uint16_t Length __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** Reads the given number of bytes from the endpoint from the given buffer in big endian,
|
|
* discarding fully read packets from the host as needed. The last packet is not automatically
|
|
* discarded once the remaining bytes has been read; the user is responsible for manually
|
|
* discarding the last packet from the host via the \ref Endpoint_ClearOUT() macro. Between
|
|
* each USB packet, the given stream callback function is executed repeatedly until the endpoint
|
|
* is ready to accept the next packet, allowing for early aborts of stream transfers.
|
|
*
|
|
* The callback routine should be created according to the information in \ref Group_StreamCallbacks.
|
|
* If the token NO_STREAM_CALLBACKS is passed via the -D option to the compiler, stream callbacks are
|
|
* disabled and this function has the Callback parameter omitted.
|
|
*
|
|
* \note This routine should not be used on CONTROL type endpoints.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[out] Buffer Pointer to the destination data buffer to write to.
|
|
* \param[in] Length Number of bytes to send via the currently selected endpoint.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Read_Stream_BE(void* Buffer, uint16_t Length __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** EEPROM buffer source version of \ref Endpoint_Read_Stream_BE().
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[out] Buffer Pointer to the destination data buffer to write to, located in EEPROM memory space.
|
|
* \param[in] Length Number of bytes to send via the currently selected endpoint.
|
|
* \param[in] Callback Name of a callback routine to call between successive USB packet transfers, NULL if no callback
|
|
*
|
|
* \return A value from the \ref Endpoint_Stream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Read_EStream_BE(void* Buffer, uint16_t Length __CALLBACK_PARAM) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in little endian,
|
|
* sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared
|
|
* in both failure and success states; the user is responsible for manually clearing the setup OUT to
|
|
* finalize the transfer via the \ref Endpoint_ClearOUT() macro.
|
|
*
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
*
|
|
* \note This routine should only be used on CONTROL type endpoints.
|
|
*
|
|
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
|
|
* together; i.e. the entire stream data must be read or written at the one time.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
*
|
|
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_Control_Stream_LE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** EEPROM buffer source version of Endpoint_Write_Control_Stream_LE.
|
|
*
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
*
|
|
* \note This routine should only be used on CONTROL type endpoints.
|
|
*
|
|
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
|
|
* together; i.e. the entire stream data must be read or written at the one time.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
*
|
|
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_Control_EStream_LE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** FLASH buffer source version of \ref Endpoint_Write_Control_Stream_LE().
|
|
*
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
*
|
|
* \note The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.
|
|
*
|
|
* \note This routine should only be used on CONTROL type endpoints.
|
|
*
|
|
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
|
|
* together; i.e. the entire stream data must be read or written at the one time.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
*
|
|
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_Control_PStream_LE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in big endian,
|
|
* sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared
|
|
* in both failure and success states; the user is responsible for manually clearing the setup OUT to
|
|
* finalize the transfer via the \ref Endpoint_ClearOUT() macro.
|
|
*
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
*
|
|
* \note This routine should only be used on CONTROL type endpoints.
|
|
*
|
|
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
|
|
* together; i.e. the entire stream data must be read or written at the one time.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
*
|
|
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_Control_Stream_BE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** EEPROM buffer source version of \ref Endpoint_Write_Control_Stream_BE().
|
|
*
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
*
|
|
* \note This routine should only be used on CONTROL type endpoints.
|
|
*
|
|
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
|
|
* together; i.e. the entire stream data must be read or written at the one time.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
*
|
|
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_Control_EStream_BE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** FLASH buffer source version of \ref Endpoint_Write_Control_Stream_BE().
|
|
*
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
*
|
|
* \note The FLASH data must be located in the first 64KB of FLASH for this function to work correctly.
|
|
*
|
|
* \note This routine should only be used on CONTROL type endpoints.
|
|
*
|
|
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
|
|
* together; i.e. the entire stream data must be read or written at the one time.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[in] Buffer Pointer to the source data buffer to read from.
|
|
* \param[in] Length Number of bytes to read for the currently selected endpoint into the buffer.
|
|
*
|
|
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Write_Control_PStream_BE(const void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** Reads the given number of bytes from the CONTROL endpoint from the given buffer in little endian,
|
|
* discarding fully read packets from the host as needed. The device IN acknowledgement is not
|
|
* automatically sent after success or failure states; the user is responsible for manually sending the
|
|
* setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.
|
|
*
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
*
|
|
* \note This routine should only be used on CONTROL type endpoints.
|
|
*
|
|
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
|
|
* together; i.e. the entire stream data must be read or written at the one time.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[out] Buffer Pointer to the destination data buffer to write to.
|
|
* \param[in] Length Number of bytes to send via the currently selected endpoint.
|
|
*
|
|
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Read_Control_Stream_LE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** EEPROM buffer source version of \ref Endpoint_Read_Control_Stream_LE().
|
|
*
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
*
|
|
* \note This routine should only be used on CONTROL type endpoints.
|
|
*
|
|
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
|
|
* together; i.e. the entire stream data must be read or written at the one time.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[out] Buffer Pointer to the destination data buffer to write to.
|
|
* \param[in] Length Number of bytes to send via the currently selected endpoint.
|
|
*
|
|
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Read_Control_EStream_LE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** Reads the given number of bytes from the CONTROL endpoint from the given buffer in big endian,
|
|
* discarding fully read packets from the host as needed. The device IN acknowledgement is not
|
|
* automatically sent after success or failure states; the user is responsible for manually sending the
|
|
* setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.
|
|
*
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
*
|
|
* \note This routine should only be used on CONTROL type endpoints.
|
|
*
|
|
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
|
|
* together; i.e. the entire stream data must be read or written at the one time.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[out] Buffer Pointer to the destination data buffer to write to.
|
|
* \param[in] Length Number of bytes to send via the currently selected endpoint.
|
|
*
|
|
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Read_Control_Stream_BE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/** EEPROM buffer source version of \ref Endpoint_Read_Control_Stream_BE().
|
|
*
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
*
|
|
* \note This routine should only be used on CONTROL type endpoints.
|
|
*
|
|
* \warning Unlike the standard stream read/write commands, the control stream commands cannot be chained
|
|
* together; i.e. the entire stream data must be read or written at the one time.
|
|
*
|
|
* \ingroup Group_EndpointStreamRW
|
|
*
|
|
* \param[out] Buffer Pointer to the destination data buffer to write to.
|
|
* \param[in] Length Number of bytes to send via the currently selected endpoint.
|
|
*
|
|
* \return A value from the \ref Endpoint_ControlStream_RW_ErrorCodes_t enum.
|
|
*/
|
|
uint8_t Endpoint_Read_Control_EStream_BE(void* Buffer, uint16_t Length) ATTR_NON_NULL_PTR_ARG(1);
|
|
|
|
/* Private Interface - For use in library only: */
|
|
#if !defined(__DOXYGEN__)
|
|
/* Macros: */
|
|
#define Endpoint_AllocateMemory() MACROS{ UECFG1X |= (1 << ALLOC); }MACROE
|
|
#define Endpoint_DeallocateMemory() MACROS{ UECFG1X &= ~(1 << ALLOC); }MACROE
|
|
|
|
#define _ENDPOINT_GET_MAXSIZE(n) _ENDPOINT_GET_MAXSIZE2(ENDPOINT_DETAILS_EP ## n)
|
|
#define _ENDPOINT_GET_MAXSIZE2(details) _ENDPOINT_GET_MAXSIZE3(details)
|
|
#define _ENDPOINT_GET_MAXSIZE3(maxsize, db) maxsize
|
|
|
|
#define _ENDPOINT_GET_DOUBLEBANK(n) _ENDPOINT_GET_DOUBLEBANK2(ENDPOINT_DETAILS_EP ## n)
|
|
#define _ENDPOINT_GET_DOUBLEBANK2(details) _ENDPOINT_GET_DOUBLEBANK3(details)
|
|
#define _ENDPOINT_GET_DOUBLEBANK3(maxsize, db) db
|
|
|
|
#if defined(USB_SERIES_4_AVR) || defined(USB_SERIES_6_AVR) || defined(USB_SERIES_7_AVR)
|
|
#define ENDPOINT_DETAILS_EP0 64, true
|
|
#define ENDPOINT_DETAILS_EP1 256, true
|
|
#define ENDPOINT_DETAILS_EP2 64, true
|
|
#define ENDPOINT_DETAILS_EP3 64, true
|
|
#define ENDPOINT_DETAILS_EP4 64, true
|
|
#define ENDPOINT_DETAILS_EP5 64, true
|
|
#define ENDPOINT_DETAILS_EP6 64, true
|
|
#else
|
|
#define ENDPOINT_DETAILS_EP0 64, true
|
|
#define ENDPOINT_DETAILS_EP1 64, false
|
|
#define ENDPOINT_DETAILS_EP2 64, false
|
|
#define ENDPOINT_DETAILS_EP3 64, true
|
|
#define ENDPOINT_DETAILS_EP4 64, true
|
|
#endif
|
|
|
|
#define Endpoint_ConfigureEndpoint(Number, Type, Direction, Size, Banks) \
|
|
Endpoint_ConfigureEndpoint_Prv((Number), \
|
|
(((Type) << EPTYPE0) | (Direction)), \
|
|
((1 << ALLOC) | (Banks) | \
|
|
(__builtin_constant_p(Size) ? \
|
|
Endpoint_BytesToEPSizeMask(Size) : \
|
|
Endpoint_BytesToEPSizeMaskDynamic(Size))))
|
|
|
|
/* Function Prototypes: */
|
|
void Endpoint_ClearEndpoints(void);
|
|
uint8_t Endpoint_BytesToEPSizeMaskDynamic(const uint16_t Size);
|
|
bool Endpoint_ConfigureEndpoint_Prv(const uint8_t Number, const uint8_t UECFG0XData, const uint8_t UECFG1XData);
|
|
|
|
/* Inline Functions: */
|
|
static inline uint8_t Endpoint_BytesToEPSizeMask(const uint16_t Bytes) ATTR_WARN_UNUSED_RESULT ATTR_CONST ATTR_ALWAYS_INLINE;
|
|
static inline uint8_t Endpoint_BytesToEPSizeMask(const uint16_t Bytes)
|
|
{
|
|
uint8_t MaskVal = 0;
|
|
uint16_t CheckBytes = 8;
|
|
|
|
while (CheckBytes < Bytes)
|
|
{
|
|
MaskVal++;
|
|
CheckBytes <<= 1;
|
|
}
|
|
|
|
return (MaskVal << EPSIZE0);
|
|
}
|
|
|
|
#endif
|
|
|
|
/* Disable C linkage for C++ Compilers: */
|
|
#if defined(__cplusplus)
|
|
}
|
|
#endif
|
|
|
|
#endif
|
|
|
|
/** @} */
|