You can not select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
qmk_firmware/Projects/Webserver/Webserver.txt

87 lines
3.2 KiB

/** \file
*
* This file contains special DoxyGen information for the generation of the main page and other special
* documentation pages. It is not a project source file.
*/
/** \mainpage uIP Powered Webserver Project
*
* \section SSec_Compat Project Compatibility:
*
* The following list indicates what microcontrollers are compatible with this project.
*
* - Series 7 USB AVRs
*
* \section SSec_Info USB Information:
*
* The following table gives a rundown of the USB utilization of this project.
*
* <table>
* <tr>
* <td><b>USB Mode:</b></td>
* <td>Host</td>
* </tr>
* <tr>
* <td><b>USB Class:</b></td>
* <td>Communications Device Class (CDC)</td>
* </tr>
* <tr>
* <td><b>USB Subclass:</b></td>
* <td>Remote NDIS (Microsoft Proprietary CDC Class Networking Standard)</td>
* </tr>
* <tr>
* <td><b>Relevant Standards:</b></td>
* <td>Microsoft RNDIS Specification</td>
* </tr>
* <tr>
* <td><b>Usable Speeds:</b></td>
* <td>Full Speed Mode</td>
* </tr>
* </table>
*
* \section SSec_Description Project Description:
*
* Simple HTTP webserver project. This project combines the LUFA library with the uIP TCP/IP full network stack, to create a
* RNDIS host capable of serving out HTTP webpages to up to 10 hosts simultaneously. This project demonstrates how the two
* libraries can be combined into a robust network enabled application, with the addition of a RNDIS network device.
*
* To use this project, plug the USB AVR into a RNDIS class device, such as a USB (desktop) modem. If compatible, the project
* will enumerate the device, set the appropriate parameters needed for connectivity and begin listening for new HTTP connections
* on port 80. The device IP, netmask and default gateway IP must be set to values appropriate for the RNDIS device being used
* for this project to work.
*
* When properly configured, the webserver can be accessed from any HTTP webrowser by typing in the device's IP address.
*
* \section SSec_Options Project Options
*
* The following defines can be found in this project, which can control the project behaviour when defined, or changed in value.
*
* <table>
* <tr>
* <td><b>Define Name:</b></td>
* <td><b>Location:</b></td>
* <td><b>Description:</b></td>
* </tr>
* <tr>
* <td>ENABLE_DHCP</td>
* <td>Makefile CDEFS</td>
* <td>When defined, enables the DHCP client for dynamic IP allocation of the network settings from a DHCP server.</td>
* </tr>
* <tr>
* <td>DEVICE_IP_ADDRESS</td>
* <td>Webserver.h</td>
* <td>IP address that the webserver should use when connected to a RNDIS device (when ENABLE_DHCP is not defined).</td>
* </tr>
* <tr>
* <td>DEVICE_NETMASK</td>
* <td>Webserver.h</td>
* <td>Netmask that the webserver should use when connected to a RNDIS device (when ENABLE_DHCP is not defined).</td>
* </tr>
* <tr>
* <td>DEVICE_GATEWAY</td>
* <td>Webserver.h</td>
* <td>Default routing gateway that the webserver should use when connected to a RNDIS device (when ENABLE_DHCP
* is not defined).</td>
* </tr>
* </table>
*/