  1. Disk Health Monitoring
  2. ----------------------
  3. ifdef::wiki[]
  4. :pve-toplevel:
  5. endif::wiki[]
  6. Although a robust and redundant storage is recommended,
  7. it can be very helpful to monitor the health of your local disks.
  8. Starting with {pve} 4.3, the package smartmontools footnote:[smartmontools homepage https://www.smartmontools.org]
  9. is installed and required. This is a set of tools to monitor and control
  10. the S.M.A.R.T. system for local hard disks.
  11. You can get the status of a disk by issuing the following command:
  12. ----
  13. # smartctl -a /dev/sdX
  14. ----
  15. where /dev/sdX is the path to one of your local disks.
  16. If the output says:
  17. ----
  18. SMART support is: Disabled
  19. ----
  20. you can enable it with the command:
  21. ----
  22. # smartctl -s on /dev/sdX
  23. ----
  24. For more information on how to use smartctl, please see `man smartctl`.
  25. By default, smartmontools daemon smartd is active and enabled, and scans
  26. the disks under /dev/sdX and /dev/hdX every 30 minutes for errors and warnings, and sends an
  27. e-mail to root if it detects a problem.
  28. For more information about how to configure smartd, please see `man smartd` and
  29. `man smartd.conf`.