@ -815,7 +815,7 @@ static bool drain_injected_commands_P() {
|
|
|
|
|
* Aborts the current queue, if any.
|
|
|
|
|
* Note: drain_injected_commands_P() must be called repeatedly to drain the commands afterwards
|
|
|
|
|
*/
|
|
|
|
|
void enqueue_and_echo_commands_P(const char* pgcode) {
|
|
|
|
|
void enqueue_and_echo_commands_P(const char * const pgcode) {
|
|
|
|
|
injected_commands_P = pgcode;
|
|
|
|
|
drain_injected_commands_P(); // first command executed asap (when possible)
|
|
|
|
|
}
|
|
|
|
@ -2300,6 +2300,33 @@ static void clean_up_after_endstop_or_probe_move() {
|
|
|
|
|
#endif // HAS_BED_PROBE
|
|
|
|
|
|
|
|
|
|
#if HAS_LEVELING
|
|
|
|
|
|
|
|
|
|
bool leveling_is_valid() {
|
|
|
|
|
return
|
|
|
|
|
#if ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
mbl.has_mesh()
|
|
|
|
|
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
|
|
|
|
!!bilinear_grid_spacing[X_AXIS]
|
|
|
|
|
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
|
|
|
|
true
|
|
|
|
|
#else // 3POINT, LINEAR
|
|
|
|
|
true
|
|
|
|
|
#endif
|
|
|
|
|
;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
bool leveling_is_active() {
|
|
|
|
|
return
|
|
|
|
|
#if ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
mbl.active()
|
|
|
|
|
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
|
|
|
|
ubl.state.active
|
|
|
|
|
#else
|
|
|
|
|
planner.abl_enabled
|
|
|
|
|
#endif
|
|
|
|
|
;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|
* Turn bed leveling on or off, fixing the current
|
|
|
|
|
* position as-needed.
|
|
|
|
@ -2307,41 +2334,39 @@ static void clean_up_after_endstop_or_probe_move() {
|
|
|
|
|
* Disable: Current position = physical position
|
|
|
|
|
* Enable: Current position = "unleveled" physical position
|
|
|
|
|
*/
|
|
|
|
|
void set_bed_leveling_enabled(bool enable/*=true*/) {
|
|
|
|
|
#if ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
void set_bed_leveling_enabled(const bool enable/*=true*/) {
|
|
|
|
|
|
|
|
|
|
if (enable != mbl.active()) {
|
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
|
|
|
|
const bool can_change = (!enable || leveling_is_valid());
|
|
|
|
|
#else
|
|
|
|
|
constexpr bool can_change = true;
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
if (can_change && enable != leveling_is_active()) {
|
|
|
|
|
|
|
|
|
|
#if ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
|
|
|
|
|
if (!enable)
|
|
|
|
|
planner.apply_leveling(current_position[X_AXIS], current_position[Y_AXIS], current_position[Z_AXIS]);
|
|
|
|
|
|
|
|
|
|
mbl.set_active(enable && mbl.has_mesh());
|
|
|
|
|
|
|
|
|
|
if (enable && mbl.has_mesh()) planner.unapply_leveling(current_position);
|
|
|
|
|
}
|
|
|
|
|
const bool enabling = enable && leveling_is_valid();
|
|
|
|
|
mbl.set_active(enabling);
|
|
|
|
|
if (enabling) planner.unapply_leveling(current_position);
|
|
|
|
|
|
|
|
|
|
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
|
|
|
|
|
|
|
|
|
#if PLANNER_LEVELING
|
|
|
|
|
if (ubl.state.active != enable) {
|
|
|
|
|
|
|
|
|
|
if (!enable) // leveling from on to off
|
|
|
|
|
planner.apply_leveling(current_position[X_AXIS], current_position[Y_AXIS], current_position[Z_AXIS]);
|
|
|
|
|
else
|
|
|
|
|
planner.unapply_leveling(current_position);
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
ubl.state.active = enable;
|
|
|
|
|
|
|
|
|
|
#else
|
|
|
|
|
|
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
|
|
|
|
const bool can_change = (!enable || (bilinear_grid_spacing[0] && bilinear_grid_spacing[1]));
|
|
|
|
|
#else
|
|
|
|
|
constexpr bool can_change = true;
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
if (can_change && enable != planner.abl_enabled) {
|
|
|
|
|
#else // ABL
|
|
|
|
|
|
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
|
|
|
|
// Force bilinear_z_offset to re-calculate next time
|
|
|
|
@ -2360,9 +2385,10 @@ static void clean_up_after_endstop_or_probe_move() {
|
|
|
|
|
);
|
|
|
|
|
else
|
|
|
|
|
planner.unapply_leveling(current_position);
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
#endif
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
#if ENABLED(ENABLE_LEVELING_FADE_HEIGHT)
|
|
|
|
|
|
|
|
|
@ -2370,13 +2396,7 @@ static void clean_up_after_endstop_or_probe_move() {
|
|
|
|
|
planner.z_fade_height = zfh;
|
|
|
|
|
planner.inverse_z_fade_height = RECIPROCAL(zfh);
|
|
|
|
|
|
|
|
|
|
if (
|
|
|
|
|
#if ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
mbl.active()
|
|
|
|
|
#else
|
|
|
|
|
planner.abl_enabled
|
|
|
|
|
#endif
|
|
|
|
|
) {
|
|
|
|
|
if (leveling_is_active())
|
|
|
|
|
set_current_from_steppers_for_axis(
|
|
|
|
|
#if ABL_PLANAR
|
|
|
|
|
ALL_AXES
|
|
|
|
@ -2385,7 +2405,6 @@ static void clean_up_after_endstop_or_probe_move() {
|
|
|
|
|
#endif
|
|
|
|
|
);
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
#endif // LEVELING_FADE_HEIGHT
|
|
|
|
|
|
|
|
|
@ -2395,7 +2414,7 @@ static void clean_up_after_endstop_or_probe_move() {
|
|
|
|
|
void reset_bed_level() {
|
|
|
|
|
set_bed_leveling_enabled(false);
|
|
|
|
|
#if ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
if (mbl.has_mesh()) {
|
|
|
|
|
if (leveling_is_valid()) {
|
|
|
|
|
mbl.reset();
|
|
|
|
|
mbl.set_has_mesh(false);
|
|
|
|
|
}
|
|
|
|
@ -3435,7 +3454,7 @@ inline void gcode_G4() {
|
|
|
|
|
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
|
|
|
|
SERIAL_ECHOPGM("UBL");
|
|
|
|
|
#endif
|
|
|
|
|
if (planner.abl_enabled) {
|
|
|
|
|
if (leveling_is_active()) {
|
|
|
|
|
SERIAL_ECHOLNPGM(" (enabled)");
|
|
|
|
|
#if ABL_PLANAR
|
|
|
|
|
float diff[XYZ] = {
|
|
|
|
@ -3466,7 +3485,7 @@ inline void gcode_G4() {
|
|
|
|
|
#elif ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
|
|
|
|
|
SERIAL_ECHOPGM("Mesh Bed Leveling");
|
|
|
|
|
if (mbl.active()) {
|
|
|
|
|
if (leveling_is_active()) {
|
|
|
|
|
float lz = current_position[Z_AXIS];
|
|
|
|
|
planner.apply_leveling(current_position[X_AXIS], current_position[Y_AXIS], lz);
|
|
|
|
|
SERIAL_ECHOLNPGM(" (enabled)");
|
|
|
|
@ -3622,7 +3641,7 @@ inline void gcode_G28(const bool always_home_all) {
|
|
|
|
|
// Disable the leveling matrix before homing
|
|
|
|
|
#if HAS_LEVELING
|
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
|
|
|
|
const bool ubl_state_at_entry = ubl.state.active;
|
|
|
|
|
const bool ubl_state_at_entry = leveling_is_active();
|
|
|
|
|
#endif
|
|
|
|
|
set_bed_leveling_enabled(false);
|
|
|
|
|
#endif
|
|
|
|
@ -3898,8 +3917,8 @@ void home_all_axes() { gcode_G28(true); }
|
|
|
|
|
|
|
|
|
|
switch (state) {
|
|
|
|
|
case MeshReport:
|
|
|
|
|
if (mbl.has_mesh()) {
|
|
|
|
|
SERIAL_PROTOCOLLNPAIR("State: ", mbl.active() ? MSG_ON : MSG_OFF);
|
|
|
|
|
if (leveling_is_valid()) {
|
|
|
|
|
SERIAL_PROTOCOLLNPAIR("State: ", leveling_is_active() ? MSG_ON : MSG_OFF);
|
|
|
|
|
mbl_mesh_report();
|
|
|
|
|
}
|
|
|
|
|
else
|
|
|
|
@ -4201,12 +4220,12 @@ void home_all_axes() { gcode_G28(true); }
|
|
|
|
|
abl_probe_index = -1;
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
abl_should_enable = planner.abl_enabled;
|
|
|
|
|
abl_should_enable = leveling_is_active();
|
|
|
|
|
|
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
|
|
|
|
|
|
|
|
|
if (parser.seen('W')) {
|
|
|
|
|
if (!bilinear_grid_spacing[X_AXIS]) {
|
|
|
|
|
if (!leveling_is_valid()) {
|
|
|
|
|
SERIAL_ERROR_START;
|
|
|
|
|
SERIAL_ERRORLNPGM("No bilinear grid");
|
|
|
|
|
return;
|
|
|
|
@ -4518,7 +4537,6 @@ void home_all_axes() { gcode_G28(true); }
|
|
|
|
|
// Leveling done! Fall through to G29 finishing code below
|
|
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLLNPGM("Grid probing done.");
|
|
|
|
|
g29_in_progress = false;
|
|
|
|
|
|
|
|
|
|
// Re-enable software endstops, if needed
|
|
|
|
|
#if HAS_SOFTWARE_ENDSTOPS
|
|
|
|
@ -4542,7 +4560,6 @@ void home_all_axes() { gcode_G28(true); }
|
|
|
|
|
else {
|
|
|
|
|
|
|
|
|
|
SERIAL_PROTOCOLLNPGM("3-point probing done.");
|
|
|
|
|
g29_in_progress = false;
|
|
|
|
|
|
|
|
|
|
// Re-enable software endstops, if needed
|
|
|
|
|
#if HAS_SOFTWARE_ENDSTOPS
|
|
|
|
@ -4693,9 +4710,12 @@ void home_all_axes() { gcode_G28(true); }
|
|
|
|
|
if (DEBUGGING(LEVELING)) DEBUG_POS("> probing complete", current_position);
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
#if ENABLED(PROBE_MANUALLY) && ENABLED(LCD_BED_LEVELING)
|
|
|
|
|
#if ENABLED(PROBE_MANUALLY)
|
|
|
|
|
g29_in_progress = false;
|
|
|
|
|
#if ENABLED(LCD_BED_LEVELING)
|
|
|
|
|
lcd_wait_for_move = false;
|
|
|
|
|
#endif
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
// Calculate leveling, print reports, correct the position
|
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
|
|
|
@ -6591,15 +6611,7 @@ inline void gcode_M42() {
|
|
|
|
|
// Disable bed level correction in M48 because we want the raw data when we probe
|
|
|
|
|
|
|
|
|
|
#if HAS_LEVELING
|
|
|
|
|
const bool was_enabled =
|
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
|
|
|
|
ubl.state.active
|
|
|
|
|
#elif ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
mbl.active()
|
|
|
|
|
#else
|
|
|
|
|
planner.abl_enabled
|
|
|
|
|
#endif
|
|
|
|
|
;
|
|
|
|
|
const bool was_enabled = leveling_is_active();
|
|
|
|
|
set_bed_leveling_enabled(false);
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
@ -8727,14 +8739,14 @@ void quickstop_stepper() {
|
|
|
|
|
#if ABL_PLANAR
|
|
|
|
|
planner.bed_level_matrix.debug(PSTR("Bed Level Correction Matrix:"));
|
|
|
|
|
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
|
|
|
|
if (bilinear_grid_spacing[X_AXIS]) {
|
|
|
|
|
if (leveling_is_valid()) {
|
|
|
|
|
print_bilinear_leveling_grid();
|
|
|
|
|
#if ENABLED(ABL_BILINEAR_SUBDIVISION)
|
|
|
|
|
bed_level_virt_print();
|
|
|
|
|
#endif
|
|
|
|
|
}
|
|
|
|
|
#elif ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
if (mbl.has_mesh()) {
|
|
|
|
|
if (leveling_is_valid()) {
|
|
|
|
|
SERIAL_ECHOLNPGM("Mesh Bed Level data:");
|
|
|
|
|
mbl_mesh_report();
|
|
|
|
|
}
|
|
|
|
@ -8760,15 +8772,7 @@ void quickstop_stepper() {
|
|
|
|
|
if (parser.seen('Z')) set_z_fade_height(parser.value_linear_units());
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
const bool new_status =
|
|
|
|
|
#if ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
mbl.active()
|
|
|
|
|
#elif ENABLED(AUTO_BED_LEVELING_UBL)
|
|
|
|
|
ubl.state.active
|
|
|
|
|
#else
|
|
|
|
|
planner.abl_enabled
|
|
|
|
|
#endif
|
|
|
|
|
;
|
|
|
|
|
const bool new_status = leveling_is_active();
|
|
|
|
|
|
|
|
|
|
if (to_enable && !new_status) {
|
|
|
|
|
SERIAL_ERROR_START;
|
|
|
|
@ -8987,7 +8991,7 @@ inline void gcode_M503() {
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
#if ENABLED(BABYSTEP_ZPROBE_OFFSET)
|
|
|
|
|
if (!no_babystep && planner.abl_enabled)
|
|
|
|
|
if (!no_babystep && leveling_is_active())
|
|
|
|
|
thermalManager.babystep_axis(Z_AXIS, -lround(diff * planner.axis_steps_per_mm[Z_AXIS]));
|
|
|
|
|
#else
|
|
|
|
|
UNUSED(no_babystep);
|
|
|
|
@ -9801,7 +9805,7 @@ void tool_change(const uint8_t tmp_extruder, const float fr_mm_s/*=0.0*/, bool n
|
|
|
|
|
|
|
|
|
|
#if ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
|
|
|
|
|
if (mbl.active()) {
|
|
|
|
|
if (leveling_is_active()) {
|
|
|
|
|
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
|
|
|
|
if (DEBUGGING(LEVELING)) SERIAL_ECHOPAIR("Z before MBL: ", current_position[Z_AXIS]);
|
|
|
|
|
#endif
|
|
|
|
@ -11408,7 +11412,7 @@ void set_current_from_steppers_for_axis(const AxisEnum axis) {
|
|
|
|
|
inline bool prepare_move_to_destination_cartesian() {
|
|
|
|
|
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
|
|
|
|
const float fr_scaled = MMS_SCALED(feedrate_mm_s);
|
|
|
|
|
if (ubl.state.active) {
|
|
|
|
|
if (ubl.state.active) { // direct use of ubl.state.active for speed
|
|
|
|
|
ubl.line_to_destination_cartesian(fr_scaled, active_extruder);
|
|
|
|
|
return true;
|
|
|
|
|
}
|
|
|
|
@ -11421,13 +11425,13 @@ void set_current_from_steppers_for_axis(const AxisEnum axis) {
|
|
|
|
|
else {
|
|
|
|
|
const float fr_scaled = MMS_SCALED(feedrate_mm_s);
|
|
|
|
|
#if ENABLED(MESH_BED_LEVELING)
|
|
|
|
|
if (mbl.active()) {
|
|
|
|
|
if (mbl.active()) { // direct used of mbl.active() for speed
|
|
|
|
|
mesh_line_to_destination(fr_scaled);
|
|
|
|
|
return true;
|
|
|
|
|
}
|
|
|
|
|
else
|
|
|
|
|
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
|
|
|
|
|
if (planner.abl_enabled) {
|
|
|
|
|
if (planner.abl_enabled) { // direct use of abl_enabled for speed
|
|
|
|
|
bilinear_line_to_destination(fr_scaled);
|
|
|
|
|
return true;
|
|
|
|
|
}
|
|
|
|
|