@ -4389,20 +4389,57 @@ inline void gcode_M109() {
|
|
|
|
|
// Exit if S<lower>, continue if S<higher>, R<lower>, or R<higher>
|
|
|
|
|
if (no_wait_for_cooling && wants_to_cool) return;
|
|
|
|
|
|
|
|
|
|
#ifdef TEMP_BED_RESIDENCY_TIME
|
|
|
|
|
millis_t residency_start_ms = 0;
|
|
|
|
|
// Loop until the temperature has stabilized
|
|
|
|
|
#define TEMP_BED_CONDITIONS (!residency_start_ms || PENDING(now, residency_start_ms + (TEMP_BED_RESIDENCY_TIME) * 1000UL))
|
|
|
|
|
#else
|
|
|
|
|
// Loop until the temperature is very close target
|
|
|
|
|
#define TEMP_BED_CONDITIONS (wants_to_cool ? isCoolingBed() : isHeatingBed())
|
|
|
|
|
#endif //TEMP_BED_RESIDENCY_TIME
|
|
|
|
|
|
|
|
|
|
cancel_heatup = false;
|
|
|
|
|
millis_t next_temp_ms = 0;
|
|
|
|
|
millis_t now, next_temp_ms = 0;
|
|
|
|
|
|
|
|
|
|
// Wait for temperature to come close enough
|
|
|
|
|
do {
|
|
|
|
|
millis_t now = millis();
|
|
|
|
|
now = millis();
|
|
|
|
|
if (ELAPSED(now, next_temp_ms)) { //Print Temp Reading every 1 second while heating up.
|
|
|
|
|
next_temp_ms = now + 1000UL;
|
|
|
|
|
print_heaterstates();
|
|
|
|
|
SERIAL_EOL;
|
|
|
|
|
#ifdef TEMP_BED_RESIDENCY_TIME
|
|
|
|
|
SERIAL_PROTOCOLPGM(" W:");
|
|
|
|
|
if (residency_start_ms) {
|
|
|
|
|
long rem = (((TEMP_BED_RESIDENCY_TIME) * 1000UL) - (now - residency_start_ms)) / 1000UL;
|
|
|
|
|
SERIAL_PROTOCOLLN(rem);
|
|
|
|
|
}
|
|
|
|
|
else {
|
|
|
|
|
SERIAL_PROTOCOLLNPGM("?");
|
|
|
|
|
}
|
|
|
|
|
#else
|
|
|
|
|
SERIAL_EOL;
|
|
|
|
|
#endif
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
idle();
|
|
|
|
|
refresh_cmd_timeout(); // to prevent stepper_inactive_time from running out
|
|
|
|
|
} while (!cancel_heatup && (wants_to_cool ? isCoolingBed() : isHeatingBed()));
|
|
|
|
|
|
|
|
|
|
#ifdef TEMP_BED_RESIDENCY_TIME
|
|
|
|
|
|
|
|
|
|
float temp_diff = fabs(degBed() - degTargetBed());
|
|
|
|
|
|
|
|
|
|
if (!residency_start_ms) {
|
|
|
|
|
// Start the TEMP_BED_RESIDENCY_TIME timer when we reach target temp for the first time.
|
|
|
|
|
if (temp_diff < TEMP_BED_WINDOW) residency_start_ms = millis();
|
|
|
|
|
}
|
|
|
|
|
else if (temp_diff > TEMP_BED_HYSTERESIS) {
|
|
|
|
|
// Restart the timer whenever the temperature falls outside the hysteresis.
|
|
|
|
|
residency_start_ms = millis();
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
#endif //TEMP_BED_RESIDENCY_TIME
|
|
|
|
|
|
|
|
|
|
} while (!cancel_heatup && TEMP_BED_CONDITIONS);
|
|
|
|
|
LCD_MESSAGEPGM(MSG_BED_DONE);
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|