@ -414,7 +414,46 @@ const short temptable_52[][2] PROGMEM = {
};
#endif
#if (THERMISTORHEATER_0 == 55) || (THERMISTORHEATER_1 == 55) || (THERMISTORHEATER_2 == 55) || (THERMISTORBED == 55)
// 100k ATC Semitec 104GT-2 (Used on ParCan) (WITH 1kohm RESISTOR FOR PULLUP, R9 ON SANGUINOLOLU! NOT FOR 4.7kohm PULLUP! THIS IS NOT NORMAL!)
// Verified by linagee. Source: http://shop.arcol.hu/static/datasheets/thermistors.pdf
// Calculated using 1kohm pullup, voltage divider math, and manufacturer provided temp/resistance
// Advantage: More resolution and better linearity from 150C to 200C
const short temptable_52[][2] PROGMEM = {
{1*OVERSAMPLENR, 500},
{76*OVERSAMPLENR, 300},
{87*OVERSAMPLENR, 290},
{100*OVERSAMPLENR, 280},
{114*OVERSAMPLENR, 270},
{131*OVERSAMPLENR, 260},
{152*OVERSAMPLENR, 250},
{175*OVERSAMPLENR, 240},
{202*OVERSAMPLENR, 230},
{234*OVERSAMPLENR, 220},
{271*OVERSAMPLENR, 210},
{312*OVERSAMPLENR, 200},
{359*OVERSAMPLENR, 190},
{411*OVERSAMPLENR, 180},
{467*OVERSAMPLENR, 170},
{527*OVERSAMPLENR, 160},
{590*OVERSAMPLENR, 150},
{652*OVERSAMPLENR, 140},
{713*OVERSAMPLENR, 130},
{770*OVERSAMPLENR, 120},
{822*OVERSAMPLENR, 110},
{867*OVERSAMPLENR, 100},
{905*OVERSAMPLENR, 90},
{936*OVERSAMPLENR, 80},
{961*OVERSAMPLENR, 70},
{979*OVERSAMPLENR, 60},
{993*OVERSAMPLENR, 50},
{1003*OVERSAMPLENR, 40},
{1010*OVERSAMPLENR, 30},
{1015*OVERSAMPLENR, 20},
{1018*OVERSAMPLENR, 10},
{1020*OVERSAMPLENR, 0}
};