@ -567,10 +567,8 @@ static_assert(1 >= 0
# error "You probably want to use Max Endstops for DELTA!"
# elif ENABLED(ENABLE_LEVELING_FADE_HEIGHT) && DISABLED(AUTO_BED_LEVELING_BILINEAR) && !UBL_DELTA
# error "ENABLE_LEVELING_FADE_HEIGHT on DELTA requires AUTO_BED_LEVELING_BILINEAR or AUTO_BED_LEVELING_UBL."
# elif ENABLED(DELTA_AUTO_CALIBRATION) && !PROBE_SELECTED
# error "DELTA_AUTO_CALIBRATION requires a probe: PROBE_MANUALLY, FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, Z Servo."
# elif ENABLED(DELTA_AUTO_CALIBRATION) && ENABLED(PROBE_MANUALLY) && DISABLED(ULTIPANEL)
# error "DELTA_AUTO_CALIBRATION requires an LCD controller with PROBE_MANUALLY."
# elif ENABLED(DELTA_AUTO_CALIBRATION) && !(HAS_BED_PROBE || ENABLED(ULTIPANEL))
# error "DELTA_AUTO_CALIBRATION requires either a probe or an LCD Controller."
# elif ABL_GRID
# if (GRID_MAX_POINTS_X & 1) == 0 || (GRID_MAX_POINTS_Y & 1) == 0
# error "DELTA requires GRID_MAX_POINTS_X and GRID_MAX_POINTS_Y to be odd numbers."
@ -612,7 +610,7 @@ static_assert(1 >= 0
, " Please enable only one probe option: PROBE_MANUALLY, FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or Z Servo. "
) ;
# if PROBE_SELECTED
# if HAS_BED_ PROBE
/**
* Z_PROBE_SLED is incompatible with DELTA
@ -660,14 +658,14 @@ static_assert(1 >= 0
# if !HAS_Z_MIN_PROBE_PIN
# error "Z_MIN_PROBE_ENDSTOP requires the Z_MIN_PROBE_PIN to be defined."
# endif
# el if DISABLED(PROBE_MANUALLY)
# el se
# error "You must enable either Z_MIN_PROBE_ENDSTOP or Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to use a probe."
# endif
/**
* Make sure Z raise values are set
*/
# if !defined(Z_CLEARANCE_DEPLOY_PROBE)
# if ndef Z_CLEARANCE_DEPLOY_PROBE
# error "You must define Z_CLEARANCE_DEPLOY_PROBE in your configuration."
# elif !defined(Z_CLEARANCE_BETWEEN_PROBES)
# error "You must define Z_CLEARANCE_BETWEEN_PROBES in your configuration."
@ -682,14 +680,14 @@ static_assert(1 >= 0
/**
* Require some kind of probe for bed leveling and probe testing
*/
# if OLDSCHOOL_ABL
# if OLDSCHOOL_ABL && !PROBE_SELECTED
# error "Auto Bed Leveling requires one of these: PROBE_MANUALLY, FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or a Z Servo."
# endif
# if ENABLED(Z_MIN_PROBE_REPEATABILITY_TEST)
# error "Z_MIN_PROBE_REPEATABILITY_TEST requires a probe: FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or Z Servo."
# endif
# if ENABLED(Z_MIN_PROBE_REPEATABILITY_TEST) && !HAS_BED_PROBE
# error "Z_MIN_PROBE_REPEATABILITY_TEST requires a probe: FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or Z Servo."
# endif
/**
@ -724,6 +722,9 @@ static_assert(1 >= 0
* Unified Bed Leveling
*/
// Hide PROBE_MANUALLY from the rest of the code
# undef PROBE_MANUALLY
# if IS_SCARA
# error "AUTO_BED_LEVELING_UBL does not yet support SCARA printers."
# elif DISABLED(EEPROM_SETTINGS)
@ -739,7 +740,7 @@ static_assert(1 >= 0
static_assert ( WITHIN ( UBL_PROBE_PT_3_Y , MIN_PROBE_Y , MAX_PROBE_Y ) , " UBL_PROBE_PT_3_Y can't be reached by the Z probe. " ) ;
# endif
# elif HAS _ABL
# elif OLDSCHOOL _ABL
/**
* Auto Bed Leveling
@ -788,6 +789,9 @@ static_assert(1 >= 0
# elif ENABLED(MESH_BED_LEVELING)
// Hide PROBE_MANUALLY from the rest of the code
# undef PROBE_MANUALLY
/**
* Mesh Bed Leveling
*/
@ -806,8 +810,8 @@ static_assert(1 >= 0
# if ENABLED(LCD_BED_LEVELING)
# if DISABLED(ULTIPANEL)
# error "LCD_BED_LEVELING requires an LCD controller."
# elif DISABLED(MESH_BED_LEVELING) && !(HAS_ABL && ENABLED(PROBE_MANUALLY ))
# error "LCD_BED_LEVELING requires MESH_BED_LEVELING or PROBE_MANUALLY with auto bed leveling enabled ."
# elif !(ENABLED(MESH_BED_LEVELING) || (OLDSCHOOL_ABL && ENABLED(PROBE_MANUALLY) ))
# error "LCD_BED_LEVELING requires MESH_BED_LEVELING or ABL with PROBE_MANUALLY."
# endif