Clarifying M280 command in Bed Auto Leveling section.

master
alexborro 11 years ago
parent b832f5b9f6
commit 73c82e7ad8

@ -274,7 +274,7 @@ In order to get the servo working, you need to enable:
The first define tells firmware how many servos you have.
The second tells what axis this servo will be attached to. In the example above, we have a servo in Z axis.
The third one tells the angle in 2 situations: Probing (165º) and resting (60º). Check this with command M280 P0 S{angle}
The third one tells the angle in 2 situations: Probing (165º) and resting (60º). Check this with command M280 P0 S{angle} (example: M280 P0 S60 moves the servo to 60º)
Next you need to define the Z endstop (probe) offset from hotend.
My preferred method:

Loading…
Cancel
Save