Add UUID support to M115 responses.

master
Kaz Walker 11 years ago
parent c184f808f7
commit a5e8575829

@ -70,6 +70,10 @@
// Define this to set a custom name for your generic Mendel,
// #define CUSTOM_MENDEL_NAME "This Mendel"
// Define this to set a unique identifier for this printer, (Used by some programs to differentiate between machines)
// You can use an online service to generate a random UUID. (eg http://www.uuidgenerator.net/version4)
// #define MACHINE_UUID "00000000-0000-0000-0000-000000000000"
// This defines the number of extruders
#define EXTRUDERS 1
@ -96,7 +100,7 @@
// 2 is 200k thermistor - ATC Semitec 204GT-2 (4.7k pullup)
// 3 is mendel-parts thermistor (4.7k pullup)
// 4 is 10k thermistor !! do not use it for a hotend. It gives bad resolution at high temp. !!
// 5 is 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan) (4.7k pullup)
// 5 is 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (4.7k pullup)
// 6 is 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup)
// 7 is 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup)
// 71 is 100k Honeywell thermistor 135-104LAF-J01 (4.7k pullup)
@ -109,7 +113,7 @@
// (but gives greater accuracy and more stable PID)
// 51 is 100k thermistor - EPCOS (1k pullup)
// 52 is 200k thermistor - ATC Semitec 204GT-2 (1k pullup)
// 55 is 100k thermistor - ATC Semitec 104GT-2 (Used in ParCan) (1k pullup)
// 55 is 100k thermistor - ATC Semitec 104GT-2 (Used in ParCan & J-Head) (1k pullup)
#define TEMP_SENSOR_0 -1
#define TEMP_SENSOR_1 -1

@ -38,6 +38,9 @@
#else
#define MACHINE_NAME "Mendel"
#endif
#ifndef MACHINE_UUID
#define MACHINE_UUID "00000000-0000-0000-0000-000000000000"
#endif
#define FIRMWARE_URL "http://www.mendel-parts.com"
#endif
@ -163,7 +166,7 @@
#define MSG_HEATING_COMPLETE "Heating done."
#define MSG_BED_HEATING "Bed Heating."
#define MSG_BED_DONE "Bed done."
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
#define MSG_COUNT_X " Count X: "
#define MSG_ERR_KILLED "Printer halted. kill() called!"
#define MSG_ERR_STOPPED "Printer stopped due to errors. Fix the error and use M999 to restart. (Temperature is reset. Set it after restarting)"
@ -328,7 +331,7 @@
#define MSG_HEATING_COMPLETE "Nagrzewanie ekstrudera zakonczone."
#define MSG_BED_HEATING "Nagrzewanie loza..."
#define MSG_BED_DONE "Nagrzewanie loza zakonczone."
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
#define MSG_COUNT_X " Liczenie X: "
#define MSG_ERR_KILLED "Drukarka zatrzymana. Wywolano kill()"
#define MSG_ERR_STOPPED "Drukarka zatrzymana z powodu bledu. Usun problem i zrestartuj drukartke komenda M999. (temperatura zostala zresetowana; ustaw temperature po restarcie)"
@ -492,7 +495,7 @@
#define MSG_HEATING_COMPLETE "Chauffe terminee."
#define MSG_BED_HEATING "Chauffe du lit."
#define MSG_BED_DONE "Chauffe du lit terminee."
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
#define MSG_COUNT_X " Compteur X: "
#define MSG_ERR_KILLED "Impression arretee. kill() appelee!"
#define MSG_ERR_STOPPED "Impression arretee a cause d'erreurs. Corriger les erreurs et utiliser M999 pour la reprendre. (Temperature remise a zero. Reactivez la apres redemarrage)"
@ -659,7 +662,7 @@
#define MSG_HEATING_COMPLETE "Heating done."
#define MSG_BED_HEATING "Bed Heating."
#define MSG_BED_DONE "Bed done."
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
#define MSG_COUNT_X " Count X:"
#define MSG_ERR_KILLED "Printer halted. kill() called !!"
#define MSG_ERR_STOPPED "Printer stopped due to errors. Fix the error and use M999 to restart!"
@ -830,7 +833,7 @@
#define MSG_HEATING_COMPLETE "Calentamiento Hecho."
#define MSG_BED_HEATING "Calentando la base."
#define MSG_BED_DONE "Base Caliente."
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
#define MSG_COUNT_X " Cuenta X:"
#define MSG_ERR_KILLED "¡¡Impresora Parada con kill()!!"
#define MSG_ERR_STOPPED "¡Impresora parada por errores. Arregle el error y use M999 Para reiniciar!. (La temperatura se reestablece. Ajustela antes de continuar)"
@ -991,7 +994,7 @@
#define MSG_HEATING_COMPLETE "Наргето. "
#define MSG_BED_HEATING "Нагрев стола... "
#define MSG_BED_DONE "Стол нагрет. "
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
#define MSG_COUNT_X " Count X:"
#define MSG_ERR_KILLED "Принтер остановлен. вызов kill() !!"
#define MSG_ERR_STOPPED "Ошибка принтера, останов. Устраните неисправность и используйте M999 для перезагрузки!. (Температура недоступна. Проверьте датчики)"
@ -1152,7 +1155,7 @@
#define MSG_HEATING_COMPLETE "Stampante Calda."
#define MSG_BED_HEATING "Riscaldamento Piatto."
#define MSG_BED_DONE "Piatto Pronto."
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
#define MSG_COUNT_X " Calcola X: "
#define MSG_ERR_KILLED "Stampante Calda. kill() chiamata !!"
#define MSG_ERR_STOPPED "Stampante fermata a causa di errori. Risolvi l'errore e usa M999 per ripartire!. (Reset temperatura. Impostala prima di ripartire)"
@ -1322,7 +1325,7 @@
#define MSG_HEATING_COMPLETE "Aquecido."
#define MSG_BED_HEATING "Aquecendo a Base."
#define MSG_BED_DONE "Base quente."
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
#define MSG_COUNT_X " Conta X:"
#define MSG_ERR_KILLED "Impressora parada com kill() !!"
#define MSG_ERR_STOPPED "Impressora parada por erros. Coserte o erro e use M999 para recomeçar!. (Temperatura reiniciada. Ajuste antes de recomeçar)"
@ -1488,7 +1491,7 @@
#define MSG_HEATING_COMPLETE "Lammitys valmis."
#define MSG_BED_HEATING "Alusta lampiaa."
#define MSG_BED_DONE "Alusta valmis."
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) "\n"
#define MSG_M115_REPORT "FIRMWARE_NAME:Marlin V1; Sprinter/grbl mashup for gen6 FIRMWARE_URL:" FIRMWARE_URL " PROTOCOL_VERSION:" PROTOCOL_VERSION " MACHINE_TYPE:" MACHINE_NAME " EXTRUDER_COUNT:" STRINGIFY(EXTRUDERS) " UUID:" MACHINE_UUID "\n"
#define MSG_COUNT_X " Laskuri X: "
#define MSG_ERR_KILLED "Tulostin pysaytetty. kill():ia kutsuttu!"
#define MSG_ERR_STOPPED "Tulostin pysaytetty virheiden vuoksi. Korjaa virheet ja kayta M999 kaynnistaaksesi uudelleen. (Lampotila nollattiin. Aseta lampotila sen jalkeen kun jatkat.)"

Loading…
Cancel
Save