M190 bed temp was never reached

master
João Brázio 9 years ago
parent 4b697938e6
commit c6577aea60

@ -4307,7 +4307,7 @@ inline void gcode_M109() {
cancel_heatup = false; cancel_heatup = false;
millis_t now = millis(), next_temp_ms = now + 1000UL; millis_t now = millis(), next_temp_ms = now + 1000UL;
while (!cancel_heatup && degTargetBed() != degBed()) { while (!cancel_heatup && fabs(degTargetBed() - degBed()) < 0.75f) {
millis_t now = millis(); millis_t now = millis();
if (now > next_temp_ms) { //Print Temp Reading every 1 second while heating up. if (now > next_temp_ms) { //Print Temp Reading every 1 second while heating up.
next_temp_ms = now + 1000UL; next_temp_ms = now + 1000UL;

Loading…