|
|
|
@ -336,8 +336,8 @@
|
|
|
|
|
|
|
|
|
|
/** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in little endian,
|
|
|
|
|
* sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared
|
|
|
|
|
* in both failure and success states; the user is responsible for manually clearing the setup OUT to
|
|
|
|
|
* finalize the transfer via the \ref Endpoint_ClearOUT() macro.
|
|
|
|
|
* in both failure and success states; the user is responsible for manually clearing the status OUT packet
|
|
|
|
|
* to finalize the transfer's status stage via the \ref Endpoint_ClearOUT() macro.
|
|
|
|
|
*
|
|
|
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
|
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
|
|
@ -358,8 +358,8 @@
|
|
|
|
|
|
|
|
|
|
/** Writes the given number of bytes to the CONTROL type endpoint from the given buffer in big endian,
|
|
|
|
|
* sending full packets to the host as needed. The host OUT acknowledgement is not automatically cleared
|
|
|
|
|
* in both failure and success states; the user is responsible for manually clearing the setup OUT to
|
|
|
|
|
* finalize the transfer via the \ref Endpoint_ClearOUT() macro.
|
|
|
|
|
* in both failure and success states; the user is responsible for manually clearing the status OUT packet
|
|
|
|
|
* to finalize the transfer's status stage via the \ref Endpoint_ClearOUT() macro.
|
|
|
|
|
*
|
|
|
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
|
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
|
|
@ -381,7 +381,7 @@
|
|
|
|
|
/** Reads the given number of bytes from the CONTROL endpoint from the given buffer in little endian,
|
|
|
|
|
* discarding fully read packets from the host as needed. The device IN acknowledgement is not
|
|
|
|
|
* automatically sent after success or failure states; the user is responsible for manually sending the
|
|
|
|
|
* setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.
|
|
|
|
|
* status IN packet to finalize the transfer's status stage via the \ref Endpoint_ClearIN() macro.
|
|
|
|
|
*
|
|
|
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
|
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
|
|
@ -403,7 +403,7 @@
|
|
|
|
|
/** Reads the given number of bytes from the CONTROL endpoint from the given buffer in big endian,
|
|
|
|
|
* discarding fully read packets from the host as needed. The device IN acknowledgement is not
|
|
|
|
|
* automatically sent after success or failure states; the user is responsible for manually sending the
|
|
|
|
|
* setup IN to finalize the transfer via the \ref Endpoint_ClearIN() macro.
|
|
|
|
|
* status IN packet to finalize the transfer's status stage via the \ref Endpoint_ClearIN() macro.
|
|
|
|
|
*
|
|
|
|
|
* \note This function automatically clears the control transfer's status stage. Do not manually attempt
|
|
|
|
|
* to clear the status stage when using this routine in a control transaction.
|
|
|
|
|