Merge pull request #965 from bq/forced_heating_stop

Fixed stop print LCD function on M104
master
daid 11 years ago
commit 4c823224b0

@ -1946,13 +1946,15 @@ void process_commands()
/* See if we are heating up or cooling down */
target_direction = isHeatingHotend(tmp_extruder); // true if heating, false if cooling
cancel_heatup = false;
#ifdef TEMP_RESIDENCY_TIME
long residencyStart;
residencyStart = -1;
/* continue to loop until we have reached the target temp
_and_ until TEMP_RESIDENCY_TIME hasn't passed since we reached it */
while((residencyStart == -1) ||
(residencyStart >= 0 && (((unsigned int) (millis() - residencyStart)) < (TEMP_RESIDENCY_TIME * 1000UL))) ) {
while((!cancel_heatup)&&((residencyStart == -1) ||
(residencyStart >= 0 && (((unsigned int) (millis() - residencyStart)) < (TEMP_RESIDENCY_TIME * 1000UL)))) ) {
#else
while ( target_direction ? (isHeatingHotend(tmp_extruder)) : (isCoolingHotend(tmp_extruder)&&(CooldownNoWait==false)) ) {
#endif //TEMP_RESIDENCY_TIME
@ -2009,9 +2011,10 @@ void process_commands()
}
codenum = millis();
cancel_heatup = false;
target_direction = isHeatingBed(); // true if heating, false if cooling
while ( target_direction ? (isHeatingBed()) : (isCoolingBed()&&(CooldownNoWait==false)) )
while ( (target_direction)&&(!cancel_heatup) ? (isHeatingBed()) : (isCoolingBed()&&(CooldownNoWait==false)) )
{
if(( millis() - codenum) > 1000 ) //Print Temp Reading every 1 second while heating up.
{

@ -19,6 +19,7 @@ int absPreheatHotendTemp;
int absPreheatHPBTemp;
int absPreheatFanSpeed;
bool cancel_heatup = false ;
#ifdef ULTIPANEL
static float manual_feedrate[] = MANUAL_FEEDRATE;
@ -256,6 +257,8 @@ static void lcd_sdcard_stop()
enquecommand_P(PSTR(SD_FINISHED_RELEASECOMMAND));
}
autotempShutdown();
cancel_heatup = true;
}
/* Menu implementation */

@ -43,6 +43,8 @@
extern int absPreheatHPBTemp;
extern int absPreheatFanSpeed;
extern bool cancel_heatup;
void lcd_buzz(long duration,uint16_t freq);
bool lcd_clicked();

Loading…
Cancel