This change introduces an improvement to G29 command on Marlin.
Auto bed leveling operation's reliability is based on the repeatability of the Z-probe switch and the servo. This change introduces an option to G29 command. When the G29 command is sent with an "e" option, during auto bed levelling the servo is not retracted between probes which decreases the bias on auto bed levelling resulting from servo.
G29 command does the auto bed probing as it is.
G29 E command engages the servo on first probing point, probes all points and retracts the servo after probing the last point.
Please comment your opinions, test on your printer and check the code on a programmer's perspective. (I am not a good programmer.)
Small changes (and formatting to confuse the diff’er) which first
allows DOGLCD and LCD_PROGRESS_BAR to be enabled in tandem, then a
#warning (rather than error) that the extra progress bar / message
options don’t apply to graphical displays at this time. This leaves
open perhaps combining the progress bar and message area in some future
(or forked custom) graphical LCD display arrangement (at which time the
relevant variables may be moved into ultralcd.cpp with externs in
ultralcd.h). I also added a conditional error that the progress bar and
the filament display may not work well together.
logo is now 110 pixels wide and starts 9 pixels in from top left corner and also 9 pixels down from same corner... this will give a 9 pixel border all way round
ver info is placed centered and there is a 9 pixel from bottom of display to ver info
The previous calc was wrong. Between N points there are only N-1 gaps,
not N.
So changing AUTO_BED_LEVELING_GRID_POINTS to
(AUTO_BED_LEVELING_GRID_POINTS-1)