9638495ed1 
								
							
								 
							
						 
						
							
							
								
								Added REPROBE_EXTENDED_RECOVERY for Hibiscus (T2251, T2376)  
							
							... 
							
							
 
							
							- Made the experimental extended probe recovery code exclusive to Hibiscus.
- Restored the older and proven probing code for other printers.
- When REPROBE_EXTENDED_RECOVERY is enabled, Will now turn off bed
  leveling prior to G29 to allow for detection of a failed probe on
  the first washer. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								2112d53cec 
								
							
								 
							
						 
						
							
							
								
								Changed BUFSIZE (T2345); Corrected slow probe.  
							
							... 
							
							
 
							
							- Corrected speed of slow probe.
- Set BUFSIZE to 5 (T2345) 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								42e596172e 
								
							
								 
							
						 
						
							
							
								
								Rewrote rewipe implementation (T2251)  
							
							... 
							
							
 
							
							- On Hibiscus, a missed probe will trigger the following recovery sequence:
   - Rehome
   - X axis leveling
   - Reprobe (from 1st point).
- On other printers, this FW will revert the old behavior of probing from
  the 1st point after a rewipe (rather than continuing from where it failed). 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								ca4a51a3d3 
								
							
								 
							
						 
						
							
							
								
								Additional adjustments for Hibiscus.  
							
							... 
							
							
 
							
							- Moved build coordinates forward 1mm.
- Changed LCD printer name.
- Moved right probe point 2mm right. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								929be0f460 
								
							
								 
							
						 
						
							
							
								
								Adjusted coordinate system for Hibiscus (T2251)  
							
							... 
							
							
 
							
							- Shifted build area 2mm to the left. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								fefb68a971 
								
							
								 
							
						 
						
							
							
								
								Hibiscus SD print keep Z axis energized (T2343)  
							
							... 
							
							
 
							
							Hibiscus will no longer de-energize the Z axis after an SD card print. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								fd8a9286a2 
								
							
								 
							
						 
						
							
							
								
								Renamed "Auto-Level" to "Level X Axis" (T2123)  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								075663dd7d 
								
							
								 
							
						 
						
							
							
								
								Shifted Hibiscus coordinate system (T2251)  
							
							... 
							
							
 
							
							- Shifted build volume left by 1mm and towards front by 1mm
- Shifted location of probe points and wipe by (+1,+1) to compensate for coordinate shift. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								2e98392930 
								
							
								 
							
						 
						
							
							
								
								Allow timer to exceed 24h (T2335)  
							
							... 
							
							
 
							
							Backport of upstream 097ffa4842 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								08d06b1c47 
								
							
								 
							
						 
						
							
							
								
								Changed FW identification string (T910)  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								97136e6144 
								
							
								 
							
						 
						
							
							
								
								Slowed down pecking speed on Hibiscus (T2329)  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								d8b8df6bac 
								
							
								 
							
						 
						
							
							
								
								Fix for progress bar never reaching 100% (T2304)  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								f05b0b347d 
								
							
								 
							
						 
						
							
							
								
								Changed Pause and Resume Extrusion length ( #2115 )  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								08686a0862 
								
							
								 
							
						 
						
							
							
								
								Changed LCD representation of Z-Offset ( #2240 )  
							
							... 
							
							
 
							
							- Z Offset now shown using two decimal places to better match the
  resolution of the encoder. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								a97dd38aed 
								
							
								 
							
						 
						
							
							
								
								Made adjustment to Hibiscus probe points.  
							
							... 
							
							
 
							
							- To avoid skipping steps on Y. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								f21ad454ad 
								
							
								 
							
						 
						
							
							
								
								Enable ACTION_ON_PAUSE and ACTION_ON_RESUME (T1830)  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								ac4fac7b6f 
								
							
								 
							
						 
						
							
							
								
								Fix menu highlight glitch, tweak scrolling code.  
							
							... 
							
							
 
							
							- Backport of fix by thinkyhead for LCD scrolling glitch (#9954 )
- May fix T1613? 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								ff936a5f92 
								
							
								 
							
						 
						
							
							
								
								Added code to release USB id on CLCD.  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								0845bc8521 
								
							
								 
							
						 
						
							
							
								
								Remove workaround; park position change.  
							
							... 
							
							
 
							
							Remove endstop workaround (T1948)
Set filament purge location to coincide with v3 dual purge location (T2115) 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								744e9dcf5a 
								
							
								 
							
						 
						
							
							
								
								Set default Mini Z-offset to round number (T2240)  
							
							... 
							
							
 
							
							- Changed from -1.377 to -1.375 so that the thousand's
  place can be zeroed from the LCD. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								febdff2013 
								
							
								 
							
						 
						
							
							
								
								USB removal/insertion now works for Quiver.  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								c3b05fc2d7 
								
							
								 
							
						 
						
							
							
								
								Fix to Hibiscus auto-level code.  
							
							... 
							
							
 
							
							- Added M400 to leveling sequence.
- Changed "levelling" to American spelling. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								cc6a04c782 
								
							
								 
							
						 
						
							
							
								
								Changed feedrate on pause (T2115).  
							
							... 
							
							
 
							
							- Reduced extrusion length on unpause to 10 mm and feedrate to 1 mm/sec
- Also added auto-leveling option for Hibiscus. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								b110fd01e7 
								
							
								 
							
						 
						
							
							
								
								Additions and fixes to CLCD.  
							
							... 
							
							
 
							
							- Fixed issue where temp updates stops updating in status screen.
    - Added feedrate controls.
    - Added tune print menu.
    - Added ability to extrude/retract from touch UI
    - Added support for M300 gcode.
    - Fixed glitches with the sound code.
    - Added USB drive code.
        - Note: This is pending the relicensing of the USB code from "GPL v2" to "GPL v2 and later"
                which the authors have agreed upon.
    - Added ability to browse directory hierarchy. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								6f8605bc63 
								
							
								 
							
						 
						
							
							
								
								Fix to Hibiscus LCD timeout (T1822)  
							
							... 
							
							
 
							
							- LCD will now properly timeout after the user leaves
  the move axis screen. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								c5973765e4 
								
							
								 
							
						 
						
							
							
								
								Disabled position display in Hibiscus UI (T1822)  
							
							... 
							
							
 
							
							- Position display is now disabled as requested by marketing.
- Merged upstream Marlin changes to GUI code. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								e8cbfacf47 
								
							
								 
							
						 
						
							
							
								
								Fixed incorrect #define  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								5520f902a7 
								
							
								 
							
						 
						
							
							
								
								Increased manual feedrate for Z movement (T1822)  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								f473aa202f 
								
							
								 
							
						 
						
							
							
								
								Bumped version number.  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								2fe21f43e9 
								
							
								 
							
						 
						
							
							
								
								Fixes to CLCD and ST7920 UIs.  
							
							... 
							
							
 
							
							- Fixed compile error with ST7920 UI.
- Corrected landscape oriented screens on CLCD.
- Added configuration type for demo CLCD. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								91b2439f3a 
								
							
								 
							
						 
						
							
							
								
								Fixed disappearing degree mark in Hibiscus UI.  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								4043424d66 
								
							
								 
							
						 
						
							
							
								
								Shifted coordinate system on Hibiscus  
							
							... 
							
							
 
							
							- Shifted coordinate system down by 2 mm in Y on Hibiscus to better center the print.
- Bumped release version to .12 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								98b62f06b2 
								
							
								 
							
						 
						
							
							
								
								Improvements to the Hibiscus LCD UI.  
							
							... 
							
							
 
							
							- The LCD now shows units such as degress and percentages
- The LCD progress bar now responds to M73
- Incorporated code changes from upstream Marlin. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								78f0d37638 
								
							
								 
							
						 
						
							
							
								
								Reduced Z backoff distance after homing.  
							
							... 
							
							
 
							
							- To avoid running into top of full volume print. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								13ac262edb 
								
							
								 
							
						 
						
							
							
								
								Improvements to CLCD code.  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								daaacf7519 
								
							
								 
							
						 
						
							
							
								
								More Improvements for Hibiscus/Quiver  
							
							... 
							
							
 
							
							- Implemented more UI touch controls (Z offsets, steps/mm, restore failsafe).
- Fix to lightweight UI when using dual nozzles 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								ac437fdd54 
								
							
								 
							
						 
						
							
							
								
								Improvements to CLCD touch UI.  
							
							... 
							
							
 
							
							- Added support for moving axis.
- Added support for adjusting temperature settings.
- Reduced memory footprint of DL cache. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								d3969b527b 
								
							
								 
							
						 
						
							
							
								
								Enhancements to the Touch UI  
							
							... 
							
							
 
							
							- Now able to set the temperature and fan speed
- Implemented a kill screen 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								e982770f60 
								
							
								 
							
						 
						
							
							
								
								Removed obsolete code; small fix to M914  
							
							... 
							
							
 
							
							- Removed Trinamic debug code (this has been superceeded by M122)
- Removed obsolete backlash compensation code
- Removed patch for LCD pause which was fixed upstream.
- Small fix to M914 where negative values were reported incorrectly. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								8ad9a2720e 
								
							
								 
							
						 
						
							
							
								
								Improvements to the Hibiscus LCD and CLCD.  
							
							... 
							
							
 
							
							- The B&W LCD will now support scrolling of long status messages
- The B&W LCD code was improved to be more efficient
- The Color LCD code now allows you to touch the temperatures to go into the temp tuning screens
  or the positions to go into the move axis screen. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								68ae8bc8ac 
								
							
								 
							
						 
						
							
							
								
								Disabled the kill button (T1953)  
							
							... 
							
							
 
							
							This fix will prevent the printer from halting if the push button
on the LCD is depressed. Since this button is inaccessible on our
printers, it is better to disable it. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								a53527d20f 
								
							
								 
							
						 
						
							
							
								
								Bumped version number.  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								06f1faa313 
								
							
								 
							
						 
						
							
							
								
								Update mini aerostruder PID (T1944)  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								0e03d1ac3f 
								
							
								 
							
						 
						
							
							
								
								First implementation of touch UI in Marlin.  
							
							... 
							
							
 
							
							- Status screen works and you can navigate the menus, but the menus
are non-functional. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								ec3f4b5e56 
								
							
								 
							
						 
						
							
							
								
								More improvements to the LCD screen.  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								ea78124172 
								
							
								 
							
						 
						
							
							
								
								Fixed some bugs  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								e9469ce9b4 
								
							
								 
							
						 
						
							
							
								
								Continuing work on the Touch UI.  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								2d879f746f 
								
							
								 
							
						 
						
							
							
								
								First implementation of touch UI in Marlin.  
							
							
 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								e9ed3e78b6 
								
							
								 
							
						 
						
							
							
								
								Reverted behavior of TAZ 5 FW.  
							
							... 
							
							
 
							
							- NO_MOTION_BEFORE_HOMING only enabled on newer printers. 
							
						 
						
							8 years ago  
				
					
						
							
							
								 
						
							
							
								179412d92c 
								
							
								 
							
						 
						
							
							
								
								Added new Marlin 1.1.8 features to Hibiscus.  
							
							... 
							
							
 
							
							- Homing now required before moving any axis.
- Software endstops now enabled to prevent crashing axes.
- Z motors now enabled at startup to hold Z axis.
- Controller fan now runs at 1/2 power at startup.
- Enabled LIN_ADVANCE with Z factor = 0 so that this can be set by a user.
- Disabled LED support on X MAX out of concern that a user may accidently short out their board. 
							
						 
						
							8 years ago